Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 189

The DOI matches its Crossref record.

Antibody Capture Immunoassay Detection of Japanese Encephalitis Virus Immunoglobulin M and G Antibodies in Cerebrospinal Fluid

Open access
Burke, Donald S., Nisalak, Ananda, Ussery, Michael A.·1982·Journal of Clinical Microbiology

Abstract

Immunoglobulin M (IgM) and IgG antibodies to Japanese encephalitis virus (JEV) were detected in acute-phase cerebrospinal fluid (CSF) specimens from patients with acute encephalitis by using a solid-phase radioimmunoassay of the antibody capture type. Of 12 patients with JEV infections subsequently proven by hemagglutination inhibition serology, 11 had JEV IgM antibodies, as measured by antibody capture radioimmunoassay, in the first CSF specimen (geometric mean titer, 1:2,500) compared with 0 of 8 patients with acute encephalitis proven not to be due to JEV. Specific IgM anti-JEV activity (units per microgram) was greater in CSF than in parallel serum specimens in all 11 positive cases by more than fourfold on the average (range, 1.4 to 13). Among seven patients with broadly reactive hemagglutination inhibition seroresponses typical of persons previously exposed to other flaviviruses, six had high levels of JEV IgG antibodies (as measured by antibody capture radioimmunoassay) in their acute-phase CSF (geometric mean titer, 1:26,000), whereas in five patients experiencing their first flavivirus infection, JEV IgG antibodies measured by antibody capture radio-immunoassay were either absent (one patient) or weakly reactive (four patients; geometric mean titer, 1:3,200). Specific IgG anti-JEV activity was greater in CSF than in parallel serum specimens in eight of the nine positive cases measured (range, 1.3- to 24-fold). The antibody capture solid-phase immunoassay approach is well suited for detecting specific antibody activity in CSF.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.16.6.1034-1042.1982

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 189

Metadata

Authors
Burke, D. S., Nisalak, A., & Ussery, M. A.
Venue
Journal of Clinical Microbiology
Published
1982-12
Volume
16
Issue
6
Pages
1034-1042
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W1532105890
Cited by
189
References
0
FWCI
10.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Antibody Capture Immunoassay Detection of Japanese Encephalitis Virus Immunoglobulin M and G Antibodies in Cerebrospinal Fluid. https://app.cochat.ai/papers/10.1128/jcm.16.6.1034-1042.1982
The paper
Burke, D. S., Nisalak, A., & Ussery, M. A. (1982). Antibody Capture Immunoassay Detection of Japanese Encephalitis Virus Immunoglobulin M and G Antibodies in Cerebrospinal Fluid. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.16.6.1034-1042.1982

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.