Colonization of bacteria on polyvinyl chloride and Teflon intravascular catheters in hospitalized patients
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
During an 8-month period all intravascular catheters were removed by sterile technique upon completion of use and submitted to the hospital microbiology laboratory. All catheters were routinely cultured by the semiquantitative culture technique, with greater than or equal to 15 colonies being defined as a positive result. Of the 687 Teflon catheters cultured, 6.9% were positive by culture, compared with 24.6% of 77 polyvinyl chloride catheters (P less than 0.001). Also, colonization of coagulase-negative staphylococci on polyvinyl chloride was more than on Teflon. These data suggest that polyvinyl chloride catheters are colonized more frequently with organisms than are Teflon catheters; additionally, there is an increased affinity of coagulase-negative staphylococci for polyvinyl chloride as compared with Teflon, substantiating our previous observations with an in vitro system. We conclude that the type of catheter material may be important in determining the incidence of catheter-related infections and in selective colonization by coagulase-negative staphylococci.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Costerton, J. W., Geesey, G. G., & Cheng, K.-J. (1978) · Scientific American · doi:10.1038/scientificamerican0178-86 · Cited by 1,441
Adherence and Growth of Coagulase-Negative Staphylococci on Surfaces of Intravenous Catheters
Peters, G., Locci, R., & Pulverer, G. (1982) · Journal of Infectious Diseases · doi:10.1093/infdis/146.4.479 · Cited by 559 · cited 3×
“Several studies have demonstrated some of the morphological features of bacterial adherence to catheter surfaces (3, 6, 8).”
BackgroundNosocomial Septicemia Due to Multiply Antibiotic-Resistant Staphylococcus epidermidis
CHRISTENSEN, G. D., BISNO, A. L., PARISI, J. T., McLAUGHLIN, B., HESTER, M. G., & LUTHER, R. W. (1982) · Annals of Internal Medicine · doi:10.7326/0003-4819-96-1-1 · Cited by 308
Bacterial adherence to polystyrene: a replica method of screening for bacterial hydrophobicity
Rosenberg, M. (1981) · Applied and Environmental Microbiology · doi:10.1128/aem.42.2.375-377.1981 · Cited by 180 · cited 1×
“The interaction of bacteria with other surfaces may depend on multiple factors, including intrinsic catheter surface features such as hydrophobicity (9), presence of trace materials (1), surface charge differences, microbial traits such as glycocalyx or pilus production (3, 5, 8), or as yet”
BackgroundEffect of trace metals on growth of Streptococcus mutans in a teflon chemostat
Aranha, H., Strachan, R. C., Arceneaux, J. E. L., & Byers, B. R. (1982) · Infection and Immunity · doi:10.1128/iai.35.2.456-460.1982 · Cited by 46 · cited 1×
“The interaction of bacteria with other surfaces may depend on multiple factors, including intrinsic catheter surface features such as hydrophobicity (9), presence of trace materials (1), surface charge differences, microbial traits such as glycocalyx or pilus production (3, 5, 8), or as yet”
BackgroundUse of chemotaxis chambers for studying in vitro bacterial colonization of biomaterials
Leake, E. S., Gristina, A. G., & Wright, M. J. (1982) · Journal of Clinical Microbiology · doi:10.1128/jcm.15.2.320-323.1982 · Cited by 26 · cited 1×
“The interaction of bacteria with other surfaces may depend on multiple factors, including intrinsic catheter surface features such as hydrophobicity (9), presence of trace materials (1), surface charge differences, microbial traits such as glycocalyx or pilus production (3, 5, 8), or as yet”
Background
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
ESPGHAN and ESPEN Guidelines Paediatric Parenteral Nutrition ‐ Annex: List of Products
(2005) · Journal of Pediatric Gastroenterology and Nutrition · doi:10.1097/01.mpg.0000181841.07090.f4 · Cited by 1,231
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
“Polytetrafluoroethylene (Teflon ) or polyurethane catheters have been associated with fewer infectious complications than catheters made of polyvinyl chloride or polyethylene [36, 253, 254].”
Guidelines for the Prevention of Intravascular Catheter-Related Infections
O’Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Pediatrics · doi:10.1542/peds.110.5.e51 · Cited by 738
Metadata
- Authors
- Sheth, N. K., Franson, T. R., Rose, H. D., Buckmire, F. L., Cooper, J. A., & Sohnle, P. G.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1983-11
- Volume
- 18
- Issue
- 5
- Pages
- 1061-1063
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1657980609
- Cited by
- 161
- References
- 7
- FWCI
- 9.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.