Detection of bacteriuria and pyuria within two minutes
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A study was performed to evaluate two rapid urine screening methods, Bac-T-Screen (Marion Laboratories, Inc., Kansas City, Mo.) and Chemstrip LN (Boehringer Mannheim Diagnostics, BioDynamics, Indianapolis, Ind.), for their ability to screen for bacteriuria and pyuria within 2 min. A total of 1,000 urine specimens were tested with the Bac-T-Screen and the Chemstrip LN and compared with a semiquantitative plate culture method. Of the 1,000 specimens tested, 249 had colony counts of greater than or equal to 10(5) CFU/ml by the culture method. Of these, the Bac-T-Screen detected 94.8% (236 of 249) and the Chemstrip LN detected 84.7% (210 of 249). There were 120 pure cultures of probable pathogens of which the Bac-T-Screen detected 97.5% (117 of 120) and the Chemstrip LN detected 91.7% (110 of 120). Leukocyte counts were performed on all specimens, and both methods have the ability to detect greater than 10 leukocytes per mm3 in a majority (greater than 93%) of the specimens. The cost per test for a negative screen is approximately $1.30 for the Bac-T-Screen and $0.40 for the Chemstrip LN. Overall there is a similar negative predictive value with both methods for bacteriuria and pyuria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnosis of Coliform Infection in Acutely Dysuric Women
Stamm, W. E., Counts, G. W., Running, K. R., Fihn, S., Turck, M., & Holmes, K. K. (1982) · New England Journal of Medicine · doi:10.1056/nejm198208193070802 · Cited by 760
Causes of the Acute Urethral Syndrome in Women
Stamm, W. E., Wagner, K. F., Amsel, R., Alexander, E. R., Turck, M., Counts, G. W., & Holmes, K. K. (1980) · New England Journal of Medicine · doi:10.1056/nejm198008213030801 · Cited by 481
Measurement of pyuria and its relation to bacteriuria
Stamm, W. E. (1983) · The American Journal of Medicine · doi:10.1016/0002-9343(83)90073-6 · Cited by 308
Cited by
Laboratory Diagnosis of Urinary Tract Infections in Adult Patients
Wilson, M. L., & Gaido, L. (2004) · Clinical Infectious Diseases · doi:10.1086/383029 · Cited by 680
“Second, the tests have better performance characteristics for detecting bacteriuria at high colony counts than at low colony counts [51].”
BackgroundThe Diagnostic Accuracy of Rapid Dipstick Tests to Predict Urinary Tract Infection
Hurlbut, T. A., & Littenberg, B. (1991) · American Journal of Clinical Pathology · doi:10.1093/ajcp/96.5.582 · Cited by 179
Urinary Tract Infection: Economic Considerations
Patton, J. P., Nash, D. B., & Abrutyn, E. (1991) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)30466-7 · Cited by 173
Laboratory in the Diagnosis and Management of Urinary Tract Infections
Pappas, P. C. (1991) · Medical Clinics of North America · doi:10.1016/s0025-7125(16)30456-4 · Cited by 169
Dipstick urinalysis and the accuracy of the clinical diagnosis of urinary tract infection
Sultana, R. V., Zalstein, S., Cameron, P., & Campbell, D. (2001) · The Journal of Emergency Medicine · doi:10.1016/s0736-4679(00)00290-0 · Cited by 72
Metadata
- Authors
- Pezzlo, M. T., Wetkowski, M. A., Peterson, E. M., & de la Maza, L. M.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1985-04
- Volume
- 21
- Issue
- 4
- Pages
- 578-581
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1694115844
- Cited by
- 42
- References
- 3
- FWCI
- 5.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.