Quantitative antimicrobial susceptibility testing of Haemophilus influenzae and Streptococcus pneumoniae by using the E-test
Open accessThe DOI matches its Crossref record.
Abstract
The E-test (PDM Epsilometer; AB Biodisk, Solna, Sweden) is an antimicrobial agent gradient-coated plastic test strip which allows MIC determinations on agar media. The test is performed in a manner similar to the agar disk diffusion procedure. A collection of Haemophilus influenzae and Streptococcus pneumoniae strains possessing various resistance mechanisms was used to evaluate the E-test method. H. influenzae strains were tested with both Haemophilus test medium (HTM) and PDM ASM II chocolate agar, while the S. pneumoniae strains were tested on Mueller-Hinton sheep blood agar. E-test MICs for a total of 10 antimicrobial agents were compared with broth microdilution MICs determined according to National Committee for Clinical Laboratory Standards methods. In general, E-test MICs for both species were quickly and easily interpreted and agreed within one log2 MIC increment in 89.8% of tests with H. influenzae and in 80.4% of pneumococcal tests. The majority of disagreements between the E-test and conventional MICs occurred with trimethoprim-sulfamethoxazole because of trailing and diffuse E-test MIC endpoints with both species. Ampicillin MICs for beta-lactamase-producing H. influenzae determined by the E-test differed at times from those determined by conventional testing because of the vagaries of interpreting colonies growing within the E-test inhibition ellipses. E-test penicillin MICs for pneumococci tended to be 1 to 2 log2 dilutions lower than those determined by using Mueller-Hinton broth supplemented with lysed horse blood. Nevertheless, strains of both species with documented resistance to the study drugs were detected by E-tests, i.e., 0.7% of the tests had very major errors with H. influenzae and 0.8% had very major errors with S. pneumoniae. Thus, the E-test represents a potential alternative method for antimicrobial susceptibility testing of these two fastidious bacterial species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evaluation of the E test for susceptibility testing of anaerobic bacteria
Citron, D. M., Ostovari, M. I., Karlsson, A., & Goldstein, E. J. (1991) · Journal of Clinical Microbiology · doi:10.1128/jcm.29.10.2197-2203.1991 · Cited by 259
Jorgensen, J. H., Ferraro, M. J., McElmeel, M. L., Spargo, J., Swenson, J. M., & Tenover, F. C. (1994) · Journal of Clinical Microbiology · doi:10.1128/jcm.32.1.159-163.1994 · Cited by 138
Self-citationRevankar, S. G., Kirkpatrick, W. R., McAtee, R. K., Fothergill, A. W., Redding, S. W., Rinaldi, M. G., & Patterson, T. F. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.1.153-156.1998 · Cited by 133
“Both broth and agar methods have been associated with trailing endpoints (2, 4, 5).”
A 20‐Year Epidemiological Study of Pneumococcal Meningitis
Stanek, R. J., & Mufson, M. A. (1999) · Clinical Infectious Diseases · doi:10.1086/514777 · Cited by 59
“It provides an accurate, reproducible, and efficient procedure for determining penicillin MICs [22-24].”
Background
Metadata
- Authors
- Jorgensen, J. H., Howell, A. W., & Maher, L. A.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1991-01
- Volume
- 29
- Issue
- 1
- Pages
- 109-114
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2118872904
- Cited by
- 122
- References
- 0
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative antimicrobial susceptibility testing of Haemophilus influenzae and Streptococcus pneumoniae by using the E-test. https://app.cochat.ai/papers/10.1128/jcm.29.1.109-114.1991
- The paper
- Jorgensen, J. H., Howell, A. W., & Maher, L. A. (1991). Quantitative antimicrobial susceptibility testing of Haemophilus influenzae and Streptococcus pneumoniae by using the E-test. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.29.1.109-114.1991
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.