The DOI matches its Crossref record.
Comparison of commercial enzyme immunoassay kits with plaque reduction neutralization test for detection of measles virus antibody
Open accessAbstract
Four commercially available enzyme immunoassay (EIA) kits were evaluated in comparison with the plaque reduction neutralization (PRN) test for detection of measles virus antibody. The EIA kits, Enzygnost (Behring), Diamedix, Vidas (bioMerieux Vitek), and Measlestat (Biowhittaker), were assessed with two PRN cutoff titers: a PRN titer of 8, the lowest detectable antibody level by the PRN test under the test conditions, and a titer of 120, which has been shown to be the minimum protective antibody titer. At a PRN cutoff titer of 8, the sensitivity was 88.2, 91.1, 74.6, and 69.8% for Behring, Diamedix, Vidas, and Biowhittaker EIA tests, respectively, with negative predictive values ranging from 22.7 to 45.5%. The specificity was 93.8% for Diamedix and 100% for the rest. At a PRN cutoff titer of 120, the sensitivity and specificity, respectively, were 100 and 90.7% (Behring), 98.2 and 58.8% (Diamedix), 90.6 and 94.5% (Vidas), and 85.7 and 96.4% (Biowhittaker). At this PRN cutoff titer, the negative predictive values of all EIA tests improved considerably, ranging from 70.7 to 100%. The EIA results showed an excellent association with PRN results when the PRN titers of the test samples were either < 8 or > 1,052. Discrepancies occurred especially when testing samples having PRN titers in the range of 8 to 120, indicating lack of sensitivity of the EIA tests in detecting measles virus antibody at low levels. Maternally derived measles virus antibody at this level has been shown to interfere with measles vaccine response in children and hence has implications from the standpoint of measles immunization. The ready availability, ease of operation, and rapid turnaround time are strong plus points of the EIA kits, and they could be useful in a clinical laboratory setting for routine application, but they may have limited use in vaccine-related studies and seroepidemiological surveys.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deficiency of the Humoral Immune Response to Measles Vaccine in Infants Immunized at Age 6 Months
Gans, H. A. (1998) · JAMA · doi:10.1001/jama.280.6.527 · Cited by 278
Placental transfer and decay of maternally acquired antimeasles antibodies in Nigerian children
HARTTER, H. K., OYEDELE, O. I., DIETZ, K., KREIS, S., HOFFMAN, J. P., & MULLER, C. P. (2000) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-200007000-00010 · Cited by 113
Metadata
- Authors
- Ratnam, S., Gadag, V, West, R., Burris, J., Oates, E., Stead, F., & Bouilianne, N.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1995-04
- Volume
- 33
- Issue
- 4
- Pages
- 811-815
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2141330703
- Cited by
- 161
- References
- 0
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of commercial enzyme immunoassay kits with plaque reduction neutralization test for detection of measles virus antibody. https://app.cochat.ai/papers/10.1128/jcm.33.4.811-815.1995
- The paper
- Ratnam, S., Gadag, V, West, R., Burris, J., Oates, E., Stead, F., & Bouilianne, N. (1995). Comparison of commercial enzyme immunoassay kits with plaque reduction neutralization test for detection of measles virus antibody. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.33.4.811-815.1995
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.