CoChat

Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia

Open access
Weinstein, M P, Mirrett, S, Reimer, L G, Wilson, M L, Smith-Elekes, S, Chuard, C R, Joho, K L, Reller, L B · 1995 · Journal of Clinical Microbiology
Cited by 143

The DOI matches its Crossref record.

Abstract

A new medium, FAN, designed to enhance the recovery of microorganisms, has been developed for the BacT/Alert blood culture system (Organon Teknika Corp., Durham, N.C.). We compared the yield and speed of detection of microorganisms in 6,847 adequately filled paired aerobic standard and FAN bottles at four university hospitals. Of 499 clinically significant microorganisms isolated from one or both bottles, significantly more Staphylococcus aureus isolates (P < 0.001), coagulase-negative staphylococci (P < 0.001), yeasts (P < 0.01), and all microorganisms combined (P < 0.001) were recovered from the FAN bottles. Overall, the speeds of detection of positive cultures did not differ between the two medium formulations; mean times to detection in the standard and FAN bottles were 16.1 and 16.0 h, respectively. When a subset of patients on antimicrobial therapy was evaluated, significantly enhanced yield from the FAN bottle was evident for staphylococci. Overall, the FAN bottle outperformed the standard aerobic BacT/Alert bottle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.33.4.978-981.1995

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 143

Metadata

Authors
Weinstein, M. P., Mirrett, S., Reimer, L. G., Wilson, M. L., Smith-Elekes, S., Chuard, C. R., Joho, K. L., & Reller, L. B.
Venue
Journal of Clinical Microbiology
Published
1995-04
Volume
33
Issue
4
Pages
978-981
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2159421761
Cited by
143
References
0
FWCI
5.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. https://app.cochat.ai/papers/10.1128/jcm.33.4.978-981.1995
The paper
Weinstein, M. P., Mirrett, S., Reimer, L. G., Wilson, M. L., Smith-Elekes, S., Chuard, C. R., Joho, K. L., & Reller, L. B. (1995). Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.33.4.978-981.1995

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.