Clinical Evaluation of the Automated COBAS AMPLICOR MTB Assay for Testing Respiratory and Nonrespiratory Specimens
Open accessThe DOI matches its Crossref record.
Abstract
We evaluated the COBAS AMPLICOR PCR system (Roche Diagnostics) for the routine detection of Mycobacterium tuberculosis complex (MTBC) in clinical specimens. Diagnostic culture, considered as the reference method, was performed with BACTEC, Löwenstein-Jensen, Stonebrink, and Kirchner media. Occasionally MB-Redox, ESP, or MGIT medium was also used. A total of 643 respiratory and 506 nonrespiratory specimens collected from 807 patients were investigated. Of the 95 culture-positive specimens, 80 were COBAS AMPLICOR MTB positive, and of the 1,054 culture-negative specimens, 1,044 were COBAS AMPLICOR MTB negative. After resolving discrepancies by review of the medical history, the overall sensitivity, specificity, and positive and negative predictive values for the COBAS AMPLICOR MTB assay, respectively, were 83.5, 98.8, 86.7, and 98.6% compared to those of diagnostic culture. In smear-positive specimens, the sensitivity of the COBAS AMPLICOR MTB assay was 96%, versus 48% for smear-negative specimens. No significant differences in the test performance between respiratory and nonrespiratory specimens were observed. The overall inhibition rate was less than 2%, excluding stool specimens. The clear advantages of the COBAS AMPLICOR PCR system are standardized procedures and reagents for specimen processing as well as an internal control for reliable monitoring of PCR inhibitors. By simplifying the work flow through a completely automated amplification and amplicon detection procedure, the COBAS AMPLICOR PCR system proved itself as a very useful component for routine diagnostic procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A systematic review of rapid diagnostic tests for the detection of tuberculosis infection
Dinnes, J., Deeks, J., Kunst, H., Gibson, A., Cummins, E., Waugh, N., Drobniewski, F., & Lalvani, A. (2007) · Health Technology Assessment · doi:10.3310/hta11030 · Cited by 666
Pai, M., Flores, L. L., Pai, N., Hubbard, A., Riley, L. W., & Colford, J. M. (2003) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(03)00772-2 · Cited by 384
Pai, M., Flores, L. L., Hubbard, A., Riley, L. W., & Colford, J. M. (2004) · BMC Infectious Diseases · doi:10.1186/1471-2334-4-6 · Cited by 244
“Discussion Since conventional tests are not always helpful in establishing a diagnosis of tuberculous pleuritis, several rapid tests and biomarkers have been evaluated: Adenosine Deaminase (ADA) [12,14,45,51,59,62], Interferon-γ (IFN-γ) [59,60,62,63], lysozyme [62], soluble interleukin 2 receptors [63], and NAA tests…”
InfluentialHonoré-Bouakline, S., Vincensini, J. P., Giacuzzo, V., Lagrange, P. H., & Herrmann, J. L. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.6.2323-2329.2003 · Cited by 168
“In specific studies of pulmonary and/or extrapulmonary specimens, sensitivities ranged between 20 and 94% (4, 8, 14, 15, 36, 37, 38, 40, 42, 44, 45, 53, 54) for PCR assays of extrapulmonary specimens.”
Greco, S., Girardi, E., Navarra, A., & Saltini, C. (2006) · Thorax · doi:10.1136/thx.2005.054908 · Cited by 162
Metadata
- Authors
- Reischl, U., Lehn, N., Wolf, H., & Naumann, L.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1998-10
- Volume
- 36
- Issue
- 10
- Pages
- 2853-2860
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2124663438
- Cited by
- 132
- References
- 0
- FWCI
- 3.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Evaluation of the Automated COBAS AMPLICOR MTB Assay for Testing Respiratory and Nonrespiratory Specimens. https://app.cochat.ai/papers/10.1128/jcm.36.10.2853-2860.1998
- The paper
- Reischl, U., Lehn, N., Wolf, H., & Naumann, L. (1998). Clinical Evaluation of the Automated COBAS AMPLICOR MTB Assay for Testing Respiratory and Nonrespiratory Specimens. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.36.10.2853-2860.1998
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.