The DOI matches its Crossref record.
Evaluation of the VITEK 2 System for Rapid Identification of Medically Relevant Gram-Negative Rods
Open accessAbstract
The new VITEK 2 system (bioMérieux) was evaluated at two independent sites with the identification card for gram-negative bacilli (ID-GNB card). Of the 845 strains tested, which represented 70 different taxa belonging to either the family Enterobacteriaceae or the nonenteric bacilli, 716 (84.7%) were correctly identified at the species level. Thirty-two (3.8%) additional strains were identified to the species level after the performance of simple, rapid manual tests (oxidase, hemolysis, indole reaction, motility, and pigmentation). For 80 (9.5%) strains, these additional tests did not lead to an identification at the species level but the correct species identification was given among the organisms listed. Only 7 (0.8%) strains were misidentified, and 10 (1.2%) were not identified. Mistakes were randomly distributed over different taxa. Due to the new, more sensitive fluorescence-based technology of the VITEK 2 system, final results were available after 3 h. Since our evaluation was mainly a stress test, it is predicted that the VITEK 2 system in conjunction with the ID-GNB card would perform well under conditions of a routine clinical laboratory in identifying members of the family Enterobacteriaceae and selected species of nonenteric bacteria. This system is a promising, highly automated new tool for the rapid identification of gram-negative bacilli from human clinical specimens.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Innate Lymphoid Cells Promote Anatomical Containment of Lymphoid-Resident Commensal Bacteria
Sonnenberg, G. F., Monticelli, L. A., Alenghat, T., Fung, T. C., Hutnick, N. A., Kunisawa, J., Shibata, N., Grunberg, S., Sinha, R., Zahm, A. M., et al. (2012) · Science · doi:10.1126/science.1222551 · Cited by 737
Ligozzi, M., Bernini, C., Bonora, M. G., de Fatima, M., Zuliani, J., & Fontana, R. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.5.1681-1686.2002 · Cited by 265
Resistance to nitrofurantoin is an indicator of extensive drug-resistant (XDR) Enterobacteriaceae
Khamari, B., Kumar, P., & Pradeep, B. E. (2021) · Journal of Medical Microbiology · doi:10.1099/jmm.0.001347 · Cited by 17
Metadata
- Authors
- Funke, G., Monnet, D., deBernardis, C., von Graevenitz, A., & Freney, J.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1998-07
- Volume
- 36
- Issue
- 7
- Pages
- 1948-1952
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2152707619
- Cited by
- 196
- References
- 0
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the VITEK 2 System for Rapid Identification of Medically Relevant Gram-Negative Rods. https://app.cochat.ai/papers/10.1128/jcm.36.7.1948-1952.1998
- The paper
- Funke, G., Monnet, D., deBernardis, C., von Graevenitz, A., & Freney, J. (1998). Evaluation of the VITEK 2 System for Rapid Identification of Medically Relevant Gram-Negative Rods. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.36.7.1948-1952.1998
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.