The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Use of BACTEC MGIT 960 for Recovery of Mycobacteria from Clinical Specimens: Multicenter Study
Open accessAbstract
The BACTEC MGIT 960 instrument is a fully automated system that exploits the fluorescence of an oxygen sensor to detect growth of mycobacteria in culture. Its performance was compared to those of the radiometric BACTEC 460 instrument and egg-based Lowenstein-Jensen medium. An identical volume of sample was inoculated in different media, and incubation was carried out for 6 weeks with the automatic systems and for 8 weeks on solid media. A total of 2,567 specimens obtained from 1,631 patients were cultured in parallel. Mycobacteria belonging to nine different taxa were isolated by at least one of the culture systems, with 75% of them being represented by Mycobacterium tuberculosis complex. The best yield was obtained with the BACTEC 460 system, with 201 isolates, in comparison with 190 isolates with the BACTEC MGIT 960 system and 168 isolates with Lowenstein-Jensen medium. A similar but not significant difference was obtained when the most-represented organisms, the M. tuberculosis complex, Mycobacterium xenopi , and the Mycobacterium avium complex, were analyzed separately and when combinations of a solid medium with the BACTEC MGIT 960 system and with the BACTEC 460 system were considered. The shortest times to detection were obtained with the BACTEC MGIT 960 system (13.3 days); 1.5 days earlier than that with the BACTEC 460 system (14.8 days) and 12 days earlier than that with Lowenstein-Jensen medium (25.6 days). The BACTEC MGIT 960 system had a contamination rate of 10.0%, intermediate between those of the radiometric system (3.7%) and the egg-based medium (17.0%). We conclude, therefore, that the BACTEC MGIT 960 system is a fully automated, nonradiometric instrument that is suitable for the detection of growth of tuberculous and other mycobacterial species and that is characterized by detection times that are even shorter than that of the “gold standard,” the BACTEC 460 system. The contamination rate was higher than that for the radiometric BACTEC 460 system and needs to be improved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Manual of Clinical Microbiology.
(1980) · Annals of Internal Medicine · doi:10.7326/0003-4819-93-6-939_2 · Cited by 14,411
Clinical Microbiology Procedures Handbook
(2016) · ASM Press eBooks · doi:10.1128/9781555818814 · Cited by 2,240
The resurgence of tuberculosis: is your laboratory ready?
Tenover, F. C., Crawford, J. T., Huebner, R. E., Geiter, L. J., Horsburgh, C. R., & Good, R. C. (1993) · Journal of Clinical Microbiology · doi:10.1128/jcm.31.4.767-770.1993 · Cited by 374
Multicenter Evaluation of the BACTEC MGIT 960 System for Recovery of Mycobacteria
Hanna, B. A., Ebrahimzadeh, A., Elliott, L. B., Morgan, M. A., Novak, S. M., Rusch-Gerdes, S., Acio, M., Dunbar, D. F., Holmes, T. M., Rexer, C. H., et al. (1999) · Journal of Clinical Microbiology · doi:10.1128/jcm.37.3.748-752.1999 · Cited by 292
Pfyffer, G. E., Welscher, H. M., Kissling, P., Cieslak, C., Casal, M. J., Gutierrez, J., & Rüsch-Gerdes, S. (1997) · Journal of Clinical Microbiology · doi:10.1128/jcm.35.2.364-368.1997 · Cited by 224
Clinical evaluation of difco ESP culture system II for growth and detection of mycobacteria
Woods, G. L., Fish, G., Plaunt, M. R., et al. (1997) · Journal of Clinical Microbiology · doi:10.1128/jcm.35.1.121-124.1997 · Cited by 97
Rohner, P., Ninet, B., Metral, C., Emler, S., & Auckenthaler, R. (1997) · Journal of Clinical Microbiology · doi:10.1128/jcm.35.12.3127-3131.1997 · Cited by 96
Tortoli, E., Cichero, P., Chirillo, M. G., et al. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.5.1378-1381.1998 · Cited by 68
Self-citationPfyffer, G. E., Cieslak, C., Welscher, H. M., et al. (1997) · Journal of Clinical Microbiology · doi:10.1128/jcm.35.9.2229-2234.1997 · Cited by 68
Pfaller, M. A. (1994) · American Journal of Clinical Pathology · doi:10.1093/ajcp/101.3.329 · Cited by 57
Cited by
A systematic review of rapid diagnostic tests for the detection of tuberculosis infection
Dinnes, J., Deeks, J., Kunst, H., Gibson, A., Cummins, E., Waugh, N., Drobniewski, F., & Lalvani, A. (2007) · Health Technology Assessment · doi:10.3310/hta11030 · Cited by 666
Getahun, H., Harrington, M., O'Brien, R., & Nunn, P. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60284-0 · Cited by 550
Cruciani, M., Scarparo, C., Malena, M., Bosco, O., Serpelloni, G., & Mengoli, C. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.5.2321-2325.2004 · Cited by 291
Metadata
- Authors
- Tortoli, E., Cichero, P., Piersimoni, C., Simonetti, M. T., Gesu, G., & Nista, D.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1999-11
- Volume
- 37
- Issue
- 11
- Pages
- 3578-3582
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2136260802
- Cited by
- 257
- References
- 11
- FWCI
- 4.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of BACTEC MGIT 960 for Recovery of Mycobacteria from Clinical Specimens: Multicenter Study. https://app.cochat.ai/papers/10.1128/jcm.37.11.3578-3582.1999
- The paper
- Tortoli, E., Cichero, P., Piersimoni, C., Simonetti, M. T., Gesu, G., & Nista, D. (1999). Use of BACTEC MGIT 960 for Recovery of Mycobacteria from Clinical Specimens: Multicenter Study. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.37.11.3578-3582.1999
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.