CoChat

Ability of Laboratories To Detect Emerging Antimicrobial Resistance: Proficiency Testing and Quality Control Results from the World Health Organization's External Quality Assurance System for Antimicrobial Susceptibility Testing

Open access
Tenover, Fred C., Mohammed, M. Jasmine, Stelling, John, O'Brien, Thomas, Williams, Rosamund · 2001 · Journal of Clinical Microbiology
Cited by 107

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The accuracy of antimicrobial susceptibility data submitted by microbiology laboratories to national and international surveillance systems has been debated for a number of years. To assess the accuracy of data submitted to the World Health Organization by users of the WHONET software, the Centers for Disease Control and Prevention distributed six bacterial isolates representing key antimicrobial-resistance phenotypes to approximately 130 laboratories, all but one of which were outside of the United States, for antimicrobial susceptibility testing as part of the World Health Organization's External Quality Assurance System for Antimicrobial Susceptibility Testing. Each laboratory also was asked to submit 10 consecutive quality control values for several key organism-drug combinations. Most laboratories were able to detect methicillin (oxacillin) resistance in Staphylococcus aureus , high-level vancomycin resistance in Enterococcus faecium , and resistance to extended-spectrum cephalosporins in Klebsiella pneumoniae . Many laboratories, particularly those using disk diffusion tests, had difficulty in recognizing reduced susceptibility to penicillin in an isolate of Streptococcus pneumoniae . The most difficult phenotype for laboratories to detect was reduced susceptibility to vancomycin in an isolate of Staphylococcus epidermidis . The proficiency testing challenge also included a request for biochemical identification of a gram-negative bacillus, which most laboratories recognized as Enterobacter cloacae . Although only a small subset of laboratories have submitted their quality control data, it is clear that many of these laboratories generate disk diffusion results for oxacillin when testing S. aureus ATCC 25923 and S. pneumoniae ATCC 49619 that are outside of the acceptable quality control range. The narrow quality control range for vancomycin also proved to be a challenge for many of the laboratories submitting data; approximately 27% of results were out of range. Thus, it is important to establish the proficiency of laboratories submitting data to surveillance systems in which the organisms are tested locally, particularly for penicillin resistance in pneumococci and glycopeptide resistance in staphylococci.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.39.1.241-250.2001

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 107

Metadata

Authors
Tenover, F. C., Mohammed, M. J., Stelling, J., O'Brien, T., & Williams, R.
Venue
Journal of Clinical Microbiology
Published
2001-01
Volume
39
Issue
1
Pages
241-250
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2147205393
Cited by
107
References
2
FWCI
5.39
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ability of Laboratories To Detect Emerging Antimicrobial Resistance: Proficiency Testing and Quality Control Results from the World Health Organization's External Quality Assurance System for Antimicrobial Susceptibility Testing. https://app.cochat.ai/papers/10.1128/jcm.39.1.241-250.2001
The paper
Tenover, F. C., Mohammed, M. J., Stelling, J., O'Brien, T., & Williams, R. (2001). Ability of Laboratories To Detect Emerging Antimicrobial Resistance: Proficiency Testing and Quality Control Results from the World Health Organization's External Quality Assurance System for Antimicrobial Susceptibility Testing. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.39.1.241-250.2001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.