The DOI matches its Crossref record.
Evaluation of the VITEK 2 System for Rapid Direct Identification and Susceptibility Testing of Gram-Negative Bacilli from Positive Blood Cultures
Open accessAbstract
This study explores the possibility of combining the BacT/Alert Microbial Detection System with the VITEK 2 system to achieve rapid bacterial identification and susceptibility testing. Direct inoculation of bacterial suspension to the VITEK 2 ID-GNB card and AST-NO09 card was made by differential centrifugation of blood cultures of organisms with gram-negative enteric bacillus-like morphology. A total of 118 strains were investigated; of these, 97 (82.2%) strains were correctly identified to the species level and 21 (17.8%) strains were not identified; by comparing the results with those of the reference method of API identification systems using a pure culture, it was found that no strain had been misidentified. Among the 21 strains with no identification, 13 (61.9%) strains were nonfermenters. The direct-identification reporting time of VITEK 2 was 3.3 h. Direct testing of susceptibility to 11 antibiotics, i.e., amikacin, cefepime, ceftazidime, ciprofloxacin, gentamicin, imipenem, meropenem, netilmicin, piperacillin, piperacillin-tazobactam, and tobramycin, was also performed by using the broth microdilution (MB) method according to the NCCLS guidelines as a reference. After comparing the MICs of the VITEK 2 system with those obtained by the MB method within ±twofold dilution, it was determined that the 1,067 organism-antibiotic combinations had an overall correct rate of 97.6% (1,041 combinations). The rates of susceptibility to the 11 antibiotics ranged from 88.7 to 100%, respectively. Only two (0.2%) and four (0.4%) combinations of the susceptibility tests gave very major errors (i.e., reported as sensitive by the VITEK 2 system but shown to be resistant by the MB method) and major errors (i.e., reported as resistant by the VITEK 2 system but shown to be sensitive by the MB method), respectively. The reporting time for the direct testing of susceptibility against the 11 antibiotics for 97 blood culture isolates by the VITEK 2 system ranged from 3.3 to 17.5 h. Compared with conventional methods that require 1 or 2 days, this method can make same-day reporting possible and thus permit better patient management.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ferroni, A., Suarez, S., Beretti, J.-L., Dauphin, B., Bille, E., Meyer, J., Bougnoux, M.-E., Alanio, A., Berche, P., & Nassif, X. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.02485-09 · Cited by 283
Microbial detection and identification methods: Bench top assays to omics approaches
Ferone, M., Gowen, A., Fanning, S., & Scannell, A. G. M. (2020) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.12618 · Cited by 282
Blood culture-free ultra-rapid antimicrobial susceptibility testing
Kim, T. H., Kang, J., Jang, H., Joo, H., Lee, G. Y., Kim, H., Cho, U., Bang, H., Jang, J., Han, S., et al. (2024) · Nature · doi:10.1038/s41586-024-07725-1 · Cited by 90
Metadata
- Authors
- Ling, T. K. W., Liu, Z. K., & Cheng, A. F. B.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2003-10
- Volume
- 41
- Issue
- 10
- Pages
- 4705-4707
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2136805548
- Cited by
- 177
- References
- 0
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of the VITEK 2 System for Rapid Direct Identification and Susceptibility Testing of Gram-Negative Bacilli from Positive Blood Cultures. https://app.cochat.ai/papers/10.1128/jcm.41.10.4705-4707.2003
- The paper
- Ling, T. K. W., Liu, Z. K., & Cheng, A. F. B. (2003). Evaluation of the VITEK 2 System for Rapid Direct Identification and Susceptibility Testing of Gram-Negative Bacilli from Positive Blood Cultures. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.41.10.4705-4707.2003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.