Transfer and Evaluation of an Automated, Low-Cost Real-Time Reverse Transcription-PCR Test for Diagnosis and Monitoring of Human Immunodeficiency Virus Type 1 Infection in a West African Resource-Limited Setting
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
There is an urgent need for low-cost human immunodeficiency virus type 1 (HIV-1) viral load (VL) monitoring technologies in resource-limited settings. An automated TaqMan real-time reverse transcription-PCR (RT-PCR) assay was transferred to the laboratory of the Centre de Diagnostic et de Recherches sur le SIDA, Abidjan, Côte d'Ivoire, and assessed for HIV-1 RNA VL testing in 806 plasma samples collected within four ANRS research programs. The detection threshold and reproducibility of the assay were first determined. The quantitative results obtained with this assay were compared with two commercial HIV-1 RNA kits (the Versant version 3.0 and Monitor version 1.5 assays) in specimens harboring mainly the circulating recombinant form 02 strain (CRF02). The clinical evaluation of this test was done in different situations including the early diagnosis of pediatric infection and the monitoring of antiretroviral-treated patients. The quantification limit of our method was 300 copies/ml. The HIV-1 RNA values obtained by real-time PCR assay were highly correlated with those obtained by the Versant kit (r= 0.901;P< 0.001) and the Monitor test (r= 0.856;P< 0.001) and homogeneously distributed according to HIV-1 genotypes. For the early diagnosis of pediatric HIV-1 infection, the sensitivity and specificity of the real-time PCR assay were both 100% (95% confidence intervals of 93.7 to 100.0 and 98.3 to 100.0, respectively), compared to the Versant results. Following initiation of antiretroviral treatment, the kinetics of HIV-1 RNA levels were very comparable, with a similar proportion of adults and children below the detection limit during follow-up with our technique and the Versant assay. The TaqMan real-time PCR ($12 per test) is now routinely used to monitor HIV-1 infection in our laboratory. This technology should be further evaluated in limited-resource countries where strains other than CRF02 are prevalent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PHYLIP-Phylogeny inference package (Version 3.2)
Felsenstein, J. (1989) · Cladistics · Cited by 18,906
Holland, P. M., Abramson, R. D., Watson, R., & Gelfand, D. H. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.16.7276 · Cited by 2,693 · cited 1×
“alternative HIV VL monitoring technology (18, 28).”
Comparing methods of measurement: why plotting difference against standard method is misleading
Bland, J. M., & Altman, D. G. (1995) · The Lancet · doi:10.1016/s0140-6736(95)91748-9 · Cited by 2,343 · cited 1×
“method (1) was used to assess the agreement between values obtained with the”
MethodPalmer, S., Wiegand, A. P., Maldarelli, F., Bazmi, H., Mican, J. M., Polis, M., Dewar, R. L., Planta, A., Liu, S., Metcalf, J. A., et al. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.10.4531-4536.2003 · Cited by 604 · cited 1×
“Moreover, plasma HIV-1 RNA has been assessed by real-time PCR for multiplex nucleic acid amplification testing in blood donations (25, 26, 40) and for HAART monitoring in HIV-1-seropositive patients (15, 30).”
MethodDybul, M., Fauci, A. S., Bartlett, J. G., Kaplan, J. E., & Pau, A. K. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-5_part_2-200209031-00001 · Cited by 482
Multiplex detection of four pathogenic retroviruses using molecular beacons
Vet, J. A. M., Majithia, A. R., Marras, S. A. E., Tyagi, S., Dube, S., Poiesz, B. J., & Kramer, F. R. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.11.6394 · Cited by 322 · cited 1×
“Moreover, plasma HIV-1 RNA has been assessed by real-time PCR for multiplex nucleic acid amplification testing in blood donations (25, 26, 40) and for HAART monitoring in HIV-1-seropositive patients (15, 30).”
MethodSequence-specific identification of 18 pathogenic microorganisms using microarray technology
Wilson, W. J., Strout, C. L., DeSantis, T. Z., Stilwell, J. L., Carrano, A. V., & Andersen, G. L. (2002) · Molecular and Cellular Probes · doi:10.1006/mcpr.2001.0397 · Cited by 288 · cited 1×
“which are not yet ready to be used in routine practice (42),”
BackgroundHIV-1/AIDS and maternal and child health in Africa
Dabis, F., & Ekpini, E. R. (2002) · The Lancet · doi:10.1016/s0140-6736(02)08909-2 · Cited by 232 · cited 1×
“In sub-Saharan Africa, the increased access to antiretroviral (ARV) drugs (due to significant price reductions) allows the large-scale implementation of programs focused on the prevention of mother-to-child transmission of human immunodeficiency virus type 1 (HIV-1) (6) and the scaling up of highly active antiretrovir…”
BackgroundSelf-citationPachl, C. A., Todd, J. A., Kern, D. G., Sheridan, P. J., Fong, S.-J., Stempien, M. M., Hoo, B., Besemer, D. J., Yeghiazarian, T., Irvine, B. D., et al. (1995) · Journal of Acquired Immune Deficiency Syndromes & Human Retrovirology · doi:10.1097/00042560-199504120-00003 · Cited by 232
Quantitation of Viral Load Using Real-Time Amplification Techniques
Niesters, H. G. M. (2001) · Methods · doi:10.1006/meth.2001.1264 · Cited by 220 · cited 1×
“alternative HIV VL monitoring technology (18, 28).”
Highly active antiretroviral therapies among HIV-1-infected children in Abidjan, Côte d'Ivoire
Fassinou, P., Elenga, N., Rouet, F., Laguide, R., Kouakoussui, K. A., Timite, M., Blanche, S., & Msellati, P. (2004) · AIDS · doi:10.1097/00002030-200409240-00006 · Cited by 187
Self-citationQuantitation of HTLV-I proviral load by a TaqMan real-time PCR assay
Dehée, A., Césaire, R., Désiré, N., Lézin, A., Bourdonné, O., Béra, O., Plumelle, Y., Smadja, D., & Nicolas, J. (2002) · Journal of Virological Methods · doi:10.1016/s0166-0934(01)00445-1 · Cited by 151 · cited 1×
“herpesvirus 8 (4), human T-cell leukemia type 1 (8), cytomeg-”
BackgroundQuantification of Human Immunodeficiency Virus Type 1 Proviral Load by a TaqMan Real-Time PCR Assay
Désiré, N., Dehée, A., Schneider, V., Jacomet, C., Goujon, C. P., Girard, P., Rozenbaum, W., & Nicolas, J. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.4.1303-1310.2001 · Cited by 149 · cited 1×
“assays have been used for HIV-2 (7), HIV-1 group O (16), and HIV-1 DNA proviral load (10, 12, 44).”
MethodKatzenstein, D., Laga, M., & Moatti, J.-P. (2003) · AIDS · doi:10.1097/00002030-200317003-00001 · Cited by 82
Whole blood versus plasma spots for measurement of HIV-1 viral load in HIV-infected African patients
Mwaba, P., Cassol, S. A., Nunn, A., Pilon, R., Chintu, C., Janes, M., & Zumla, A. I. (2003) · The Lancet · doi:10.1016/s0140-6736(03)15103-3 · Cited by 71 · cited 1×
“As shown previously for commercial HIV-1 RNA kits (27), the usefulness of real-time PCR assays using dried blood spots has recently been demonstrated for the early detection of HIV-1 infection in children born to HIV-positive mothers in Thailand (W.”
BackgroundGibellini, D., Vitone, F., Gori, E., Plaça, M. L., & Re, M. C. (2003) · Journal of Virological Methods · doi:10.1016/j.jviromet.2003.09.030 · Cited by 69 · cited 1×
“Moreover, plasma HIV-1 RNA has been assessed by real-time PCR for multiplex nucleic acid amplification testing in blood donations (25, 26, 40) and for HAART monitoring in HIV-1-seropositive patients (15, 30).”
MethodMalmsten, A., Shao, X., Sjödahl, S., Fredriksson, E., Pettersson, I., Leitner, T., Källander, C. F. R., Sandström, E., & Gronowitz, J. S. (2005) · Journal of Medical Virology · doi:10.1002/jmv.20360 · Cited by 65
Braun, J. M., Plantier, J., Hellot, M., Tuaillon, É., Gueudin, M., Damond, F., Malmsten, A., Corrigan, G. E., & Simon, F. (2003) · AIDS · doi:10.1097/00002030-200302140-00006 · Cited by 61
Ho, S. K. N., Yam, W.-C., Leung, E. T. K., Wong, L.-P., Leung, J. K.-H., Lai, K. N., & Chan, T. M. (2003) · Journal of Medical Microbiology · doi:10.1099/jmm.0.05071-0 · Cited by 48 · cited 1×
“virus (17), and hepatitis C virus (41).”
HIV‐1 viral load determination based on reverse transcriptase activity recovered from human plasma
Malmsten, A., Shao, X., Aperia, K., Corrigan, G. E., Sandström, E., Källander, C. F. R., Leitner, T., & Gronowitz, J. S. (2003) · Journal of Medical Virology · doi:10.1002/jmv.10492 · Cited by 44 · cited 2×
“Two cheaper alternatives have been recently evaluated: the heat-dissociated HIV-1 p24 antigen enzymelinked immunosorbent assay (2, 32) and the reverse transcriptase activity assay kit (Cavidi ExaVir) (3, 24).”
MethodQuantification of Human Immunodeficiency Virus Type 1 Proviral DNA by Using TaqMan Technology
Zhao, Y., Yu, M., Miller, J. W., Chen, M., Bremer, E. G., Kabat, W. J., & Yogev, R. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.2.675-678.2002 · Cited by 39
Ribas, S. G., Ondoa, P., Schüpbach, J., van der Groen, G., & Fransen, K. (2003) · Journal of Virological Methods · doi:10.1016/s0166-0934(03)00219-2 · Cited by 35 · cited 1×
“linked immunosorbent assay (2, 32) and the reverse transcrip-”
MethodA multiplex real‐time PCR for quantification of HIV‐1 DNA and the human albumin gene in CD4+ cells
Eriksson, L. E., Leitner, T., Wahrén, B., Boström, A., & Falk, K. I. (2003) · Apmis · doi:10.1034/j.1600-0463.2003.1110605.x · Cited by 11
Cited by
Lab-on-a-chip devices for global health: Past studies and future opportunities
Chin, C. D., Linder, V., & Sia, S. K. (2007) · Lab Chip · doi:10.1039/b611455e · Cited by 811
Holt, N., Wang, J., Kim, K., Friedman, G., Wang, X., Taupin, V., Crooks, G. M., Kohn, D. B., Gregory, P. D., Holmes, M. C., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1663 · Cited by 677
“…blood or tissues harvested at necropsy were determined by extracting RNA from 5 × 10 5 cells using the master pure complete DNA and RNA purification kit (Epicentre Biotechnologies) and performing Taqman qPCR using a primer and probe set targeting the HIV-1 LTR region, as previously described (72).”
Earlier versus Later Start of Antiretroviral Therapy in HIV-Infected Adults with Tuberculosis
Blanc, F.-X., Sok, T., Laureillard, D., Borand, L., Rekacewicz, C., Nerrienet, E., Madec, Y., Marcy, O., Chan, S., Prak, N., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1013911 · Cited by 612
HIV therapy by a combination of broadly neutralizing antibodies in humanized mice
Klein, F., Halper-Stromberg, A., Horwitz, J. A., Gruell, H., Scheid, J. F., Bournazos, S., Mouquet, H., Spatz, L. A., Diskin, R., Abadir, A., et al. (2012) · Nature · doi:10.1038/nature11604 · Cited by 500
Innovations in optical microfluidic technologies for point-of-care diagnostics
Myers, F. B., & Lee, L. P. (2008) · Lab on a Chip · doi:10.1039/b812343h · Cited by 474
Metadata
- Authors
- Rouet, F., Ekouevi, D. K., Chaix, M.-L., Burgard, M., Inwoley, A., Tony, T. D., Danel, C., Anglaret, X., Leroy, V., Msellati, P., Dabis, F., & Rouzioux, C.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2005-06
- Volume
- 43
- Issue
- 6
- Pages
- 2709-2717
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2140243859
- Cited by
- 234
- References
- 23
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.