Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR Assays
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Diagnostic systems based on reverse transcription (RT)-PCR are widely used for the detection of viral genomes in different human specimens. The application of internal controls (IC) to monitor each step of nucleic acid amplification is necessary to prevent false-negative results due to inhibition or human error. In this study, we designed various real-time RT-PCRs utilizing the coliphage MS2 replicase gene, which differ in detection format, amplicon size, and efficiency of amplification. These noncompetitive IC assays, using TaqMan, hybridization probe, or duplex scorpion probe techniques, were tested on the LightCycler and Rotorgene systems. In our approach, clinical specimens were spiked with the control virus to monitor the efficiency of extraction, reverse transcription, and amplification steps. The MS2 RT-PCR assays were applied for internal control when using a second target hepatitis C virus RNA in duplex PCR in blood donor screening. The 95% detection limit was calculated by probit analysis to 44.9 copies per PCR (range, 38.4 to 73.4). As demonstrated routinely, application of MS2 IC assays exhibits low variability and can be applied in various RT-PCR assays. MS2 phage lysates were obtained under standard laboratory conditions. The quantification of phage and template RNA was performed by plating assays to determine PFU or via real-time RT-PCR. High stability of the MS2 phage preparations stored at −20°C, 4°C, and room temperature was demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Real-time PCR in the microbiology laboratory
Mackay, I. M. (2004) · Clinical Microbiology and Infection · doi:10.1111/j.1198-743x.2004.00722.x · Cited by 807
Diagnosing Herpesvirus Infections by Real-Time Amplification and Rapid Culture
van Doornum, G. J. J., Guldemeester, J., Osterhaus, A. D. M. E., & Niesters, H. G. M. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.2.576-580.2003 · Cited by 270 · cited 2×
“In these approaches, clinical specimens were spiked with a known amount of an animal virus (4, 13, 23) to monitor the efficiency of extraction, reverse transcription, and amplification.”
MethodRosenstraus, M., Wang, Z., Chang, S.-Y., DeBonville, D., & Spadoro, J. P. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.1.191-197.1998 · Cited by 261 · cited 1×
“Currently, most diagnostic assays in which viral RNA is detected or quantified rely on RNA standards (19).”
BackgroundClinical virology in real time
Niesters, H. G. M. (2002) · Journal of Clinical Virology · doi:10.1016/s1386-6532(02)00197-x · Cited by 245
Reduction of Norwalk Virus, Poliovirus 1, and Bacteriophage MS2 by Ozone Disinfection of Water
Shin, G.-A., & Sobsey, M. D. (2003) · Applied and Environmental Microbiology · doi:10.1128/aem.69.7.3975-3978.2003 · Cited by 226 · cited 1×
“The F -specific coliphage MS2 has been widely used as a surrogate for human enteric viruses in many studies on virus transport, disinfection, and fate (1, 5, 17, 20, 21).”
MethodArmored RNA Technology for Production of Ribonuclease-Resistant Viral RNA Controls and Standards
Pasloske, B. L., Walkerpeach, C. R., Obermoeller, R. D., Winkler, M., & DuBois, D. B. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.12.3590-3594.1998 · Cited by 211
Ultrasensitive retrovirus detection by a reversetranscriptase assay based on product enhancement.
Pyra, H., Böni, J., & Schüpbach, J. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.4.1544 · Cited by 180 · cited 1×
“The F -specific coliphage MS2 has been widely used as a surrogate for human enteric viruses in many studies on virus transport, disinfection, and fate (1, 5, 17, 20, 21).”
MethodBacteriophage Inactivation at the Air-Water-Solid Interface in Dynamic Batch Systems
Thompson, S. S., & Yates, M. V. (1999) · Applied and Environmental Microbiology · doi:10.1128/aem.65.3.1186-1190.1999 · Cited by 127 · cited 5×
“The F -specific coliphage MS2 has been widely used as a surrogate for human enteric viruses in many studies on virus transport, disinfection, and fate (1, 5, 17, 20, 21).”
MethodInfluentialBeld, M., Minnaar, R., Weel, J. F. L., Sol, C. J. A., Damen, M., van der Avoort, H., Dillen, P. M. E. W., van Breda, A., & Boom, R. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.7.3059-3064.2004 · Cited by 115 · cited 2×
“Most of these assays depend on the use of synthetic RNAs such as in vitro transcripts or armored RNA as the positive control, internal control, or external standards (3, 6, 14, 15).”
BackgroundDrosten, C., Seifried, E., & Roth, W. K. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.12.4302-4308.2001 · Cited by 88 · cited 4×
“Most of these assays depend on the use of synthetic RNAs such as in vitro transcripts or armored RNA as the positive control, internal control, or external standards (3, 6, 14, 15).”
BackgroundMethodInfluentialRapid-Cycle PCR and Fluorimetry for Detection of Mycobacteria
Lachnik, J., Ackermann, B., Bohrßen, A., Maass, S., Diephaus, C., Puncken, A., Stermann, M., & Bange, F. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.9.3364-3373.2002 · Cited by 83 · cited 1×
“The incorporation of an internal control into each RT-PCR tube is important to identify inhibitors and to eliminate falsenegative results, even when problematic specimens such as stool or bronchial lavage fluids are used (9, 10, 22).”
MethodPanning, M., Asper, M., Kramme, S., SCHMITZ, H. E., & Drosten, C. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.026781 · Cited by 73 · cited 2×
“For implementation of an internal control reaction, which would be useful for continuous monitoring of the sample preparation process, we used an HCV RT-PCR assay as described previously (14).”
BackgroundMethodUrsi, D., Dirven, K., Loens, K., Ieven, M. M., & Goossens, H. (2003) · Journal of Microbiological Methods · doi:10.1016/s0167-7012(03)00131-3 · Cited by 59 · cited 1×
“The incorporation of an internal control into each RT-PCR tube is important to identify inhibitors and to eliminate falsenegative results, even when problematic specimens such as stool or bronchial lavage fluids are used (9, 10, 22).”
MethodPoon, L. L. M., Wong, B. W. Y., Chan, K. H., Leung, C. S.-W., Yuen, K., Guan, Y., & Peiris, M. J. S. (2004) · Journal of Clinical Virology · doi:10.1016/j.jcv.2003.12.007 · Cited by 51 · cited 1×
“In gene expression analysis and virus screenings, housekeeping genes are often used as ICs and references for transcript quantification (7, 16), but they have to be proven for each experiment and target.”
BackgroundUse of internal standard RNA molecules for the RT-PCR amplification of the faeces-borne RNA viruses
Kim, K., Park, J., Chung, Y., Cheon, D., Lee, I.-B., Lee, S., Yoon, J.-D., Cho, H., Song, C., & Lee, K. (2002) · Journal of Virological Methods · doi:10.1016/s0166-0934(02)00016-2 · Cited by 7 · cited 1×
“The incorporation of an internal control into each RT-PCR tube is important to identify inhibitors and to eliminate falsenegative results, even when problematic specimens such as stool or bronchial lavage fluids are used (9, 10, 22).”
Method
Cited by
PCR inhibitors - occurrence, properties and removal
Schrader, C., Schielke, A., Ellerbroek, L., & Johne, R. (2012) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2012.05384.x · Cited by 2,118
Validation of Laboratory-Developed Molecular Assays for Infectious Diseases
Burd, E. M. (2010) · Clinical Microbiology Reviews · doi:10.1128/cmr.00074-09 · Cited by 550
Design of virus-based nanomaterials for medicine, biotechnology, and energy
Wen, A. M., & Steinmetz, N. F. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00287g · Cited by 379
A Cryptosporidium PI(4)K inhibitor is a drug candidate for cryptosporidiosis
Manjunatha, U. H., Vinayak, S., Zambriski, J. A., Chao, A. T., Sy, T., Noble, C. G., Bonamy, G. M. C., Kondreddi, R. R., Zou, B., Gedeck, P., et al. (2017) · Nature · doi:10.1038/nature22337 · Cited by 207
Murray, R. J., Robinson, J. O., White, J. N., Hughes, F., Coombs, G. W., Pearson, J. C., Tan, H.-L., Chidlow, G., Williams, S., Christiansen, K. J., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0008705 · Cited by 84
Metadata
- Authors
- Dreier, J., Störmer, M., & Kleesiek, K.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2005-09
- Volume
- 43
- Issue
- 9
- Pages
- 4551-4557
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2040499564
- Cited by
- 220
- References
- 15
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.