Rapid Susceptibility Testing of Medically Important Zygomycetes by XTT Assay

Open access
Antachopoulos, Charalampos, Meletiadis, Joseph, Roilides, Emmanuel, Sein, Tin, Walsh, Thomas J. · 2006 · Journal of Clinical Microbiology
Cited by 59

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The XTT colorimetric assay quantifies fungal growth by measuring fungal metabolism and has been used successfully for susceptibility testing of Aspergillus species after 24 and 48 h of incubation. In the present study using 14 clinical isolates of Zygomycetes ( Rhizopus oryzae [5 isolates], Cunninghamella spp. [3 isolates], Mucor spp. [3 isolates], and Absidia corymbifera [3 isolates]), significant metabolic activity was demonstrated before visual or spectrophotometric detection of fungal growth by performing the XTT assay as early as 6 h after inoculation. Testing of susceptibility to amphotericin B, posaconazole, and voriconazole was subsequently performed using the XTT method (100 μg/ml XTT, 25 μM menadione) at 6, 8, or 12 h after inoculation and the CLSI (formerly NCCLS) M38-A method with visual and spectrophotometric MIC determinations at 24 h after inoculation. Concentration-effect curves obtained with the use of the E max model (a sigmoid curve with variable slope) were comparable between the early XTT and spectrophotometric readings at 24 h. Complete inhibition of early metabolic activity with the azoles was delayed in comparison to that with amphotericin B. Using appropriate cutoff levels, agreement was demonstrated between the early XTT and 24-h spectrophotometric or visual readings. In particular, for MIC-0 (the lowest drug concentration showing absence of visual growth) of amphotericin B, overall agreement levels were 90 to 93% for the 6-h XTT assay and 100% for the 8- and 12-h time points. For MIC-0 of posaconazole, agreement levels were 86% for the 6-h XTT and 93 to 100% for the 8- and 12-h time points. The overall agreement levels for MIC-0 and MIC-2 (the lowest drug concentration showing prominent reduction of growth compared with the control well) of voriconazole (compared with 24-h spectrophotometric readings) were 93 to 98% for the 8- and 12-h XTT assays. These results support the use of the XTT method for rapid MIC determination for Zygomycetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.44.2.553-560.2006

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 59

Metadata

Authors
Antachopoulos, C., Meletiadis, J., Roilides, E., Sein, T., & Walsh, T. J.
Venue
Journal of Clinical Microbiology
Published
2006-02
Volume
44
Issue
2
Pages
553-560
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2145158961
Cited by
59
References
3
FWCI
2.29
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.