CoChat

QNOTE: an instrument for measuring the quality of EHR clinical notes

Open access
Burke, H. B., Hoang, A., Becher, D., Fontelo, P., Liu, F., Stephens, M., Pangaro, L. N., Sessums, L. L., O'Malley, P., Baxi, N. S., Bunt, C. W., Capaldi, V. F., Chen, J. M., Cooper, B. A., Djuric, D. A., Hodge, J. A., Kane, S., Magee, C., Makary, Z. R., Mallory, R. M., Miller, T., Saperstein, A., Servey, J., Gimbel, R. W. · 2014 · Journal of the American Medical Informatics Association
Cited by 78

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND OBJECTIVE: The outpatient clinical note documents the clinician's information collection, problem assessment, and patient management, yet there is currently no validated instrument to measure the quality of the electronic clinical note. This study evaluated the validity of the QNOTE instrument, which assesses 12 elements in the clinical note, for measuring the quality of clinical notes. It also compared its performance with a global instrument that assesses the clinical note as a whole. MATERIALS AND METHODS: Retrospective multicenter blinded study of the clinical notes of 100 outpatients with type 2 diabetes mellitus who had been seen in clinic on at least three occasions. The 300 notes were rated by eight general internal medicine and eight family medicine practicing physicians. The QNOTE instrument scored the quality of the note as the sum of a set of 12 note element scores, and its inter-rater agreement was measured by the intraclass correlation coefficient. The Global instrument scored the note in its entirety, and its inter-rater agreement was measured by the Fleiss κ. RESULTS: The overall QNOTE inter-rater agreement was 0.82 (CI 0.80 to 0.84), and its note quality score was 65 (CI 64 to 66). The Global inter-rater agreement was 0.24 (CI 0.19 to 0.29), and its note quality score was 52 (CI 49 to 55). The QNOTE quality scores were consistent, and the overall QNOTE score was significantly higher than the overall Global score (p=0.04). CONCLUSIONS: We found the QNOTE to be a valid instrument for evaluating the quality of electronic clinical notes, and its performance was superior to that of the Global instrument.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/amiajnl-2013-002321

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 78

Metadata

Authors
Burke, H. B., Hoang, A., Becher, D., Fontelo, P., Liu, F., Stephens, M., Pangaro, L. N., Sessums, L. L., O'Malley, P., Baxi, N. S., Bunt, C. W., Capaldi, V. F., Chen, J. M., Cooper, B. A., Djuric, D. A., Hodge, J. A., Kane, S., Magee, C., Makary, Z. R., Mallory, R. M., Miller, T., Saperstein, A., Servey, J., & Gimbel, R. W.
Venue
Journal of the American Medical Informatics Association
Published
2014-09-01
Volume
21
Issue
5
Pages
910-916
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2182584782
Cited by
78
References
1
FWCI
7.35
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: QNOTE: an instrument for measuring the quality of EHR clinical notes. https://app.cochat.ai/papers/10.1136/amiajnl-2013-002321
The paper
Burke, H. B., Hoang, A., Becher, D., Fontelo, P., Liu, F., Stephens, M., Pangaro, L. N., Sessums, L. L., O'Malley, P., Baxi, N. S., Bunt, C. W., Capaldi, V. F., Chen, J. M., Cooper, B. A., Djuric, D. A., Hodge, J. A., Kane, S., Magee, C., Makary, Z. R., . . . Gimbel, R. W. (2014). QNOTE: an instrument for measuring the quality of EHR clinical notes. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2013-002321

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.