Cited by 82Diabetes Management and ResearchHyperglycemia and glycemic control in critically ill and hospitalized patientsInfant Development and Preterm Care

Validation of the continuous glucose monitoring sensor in preterm infants

Beardsall, K, Vanhaesebrouck, S, Ogilvy-Stuart, A L, Vanhole, C, vanWeissenbruch, M, Midgley, P, Thio, M, Cornette, L +7 more·2013·Archives of Disease in Childhood - Fetal and Neonatal Edition

Abstract

Objective Recent studies have highlighted the need for improved methods of monitoring glucose control in intensive care to reduce hyperglycaemia, without increasing the risk of hypoglycaemia. Continuous glucose monitoring is increasingly used in children with diabetes, but there are little data regarding its use in the preterm infant, particularly at extremes of glucose levels and over prolonged periods. This study aimed to assess the accuracy of the continuous glucose monitoring sensor (CGMS) across the glucose profile, and to determine whether there was any deterioration over a 7 day period. Design Prospectively collected CGMS data from the NIRTURE Trial was compared with the data obtained simultaneously using point of care glucose monitors. Setting An international multicentre randomised controlled trial. Patients One hundred and eighty-eight very low birth weight control infants. Outcome measures Optimal accuracy, performance goals (American Diabetes Association consensus), Bland Altman, Error Grid analyses and accuracy. Results The mean (SD) duration of CGMS recordings was 156.18 (29) h (6.5 days), with a total of 5207 paired glucose levels. CGMS data correlated well with point of care devices (r=0.94), with minimal bias. It met the Clarke Error Grid and Consensus Grid criteria for clinical significance. Accuracy of single readings to detect set thresholds of hypoglycaemia, or hyperglycaemia was poor. There was no deterioration over time from insertion. Conclusions CGMS…

Integrity signals

Registry

Crossref · 10.1136/archdischild-2012-301661

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The lowest hypoglycaemia sensitivity of continuous glucose monitoring was reported at 17% with a hypoglycaemia threshold of 2.6 mmol/L.

    “The lowest hypoglycaemia sensitivity was reported at 17% with a hypoglycaemia threshold of 2.6mmol/L (62), as opposed to the highest hypoglycaemia sensitivity of only 86% with a hypoglycaemia threshold of 3.9mmol/L (63).”

    From Hypoglycaemia in adrenal insufficiency (2023) · cites this paper as [62]

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Beardsall, K., Vanhaesebrouck, S., Ogilvy-Stuart, A. L., Vanhole, C., vanWeissenbruch, M., Midgley, P., Thio, M., Cornette, L., Ossuetta, I., Palmer, C. R., Iglesias, I., de Jong, M., Gill, B., de Zegher, F., & Dunger, D. B.
Affiliations
  • University of Cambridge (GB)
  • KU Leuven (BE)
  • Neonatal Unit, Cambridge University Hospitals NHS Foundation Trust, Hills Road, UK
  • VU University Medical Center, Amsterdam, The Netherlands
  • Edinburgh Royal Infirmary (GB)
  • Hospital Universitari Sant Joan de Déu, Passeig Sant Joan de Deu, Esplugues, Barcelona
  • Leeds General Infirmary (GB)
  • Luton and Dunstable Hospital (GB)
  • Department of Woman and Child, University of Leuven, Leuven, Belgium
Corresponding author
Beardsall, K
Venue
Archives of Disease in Childhood - Fetal and Neonatal Edition
Publisher
BMJ
Published
2012-07-12
Volume
98
Issue
2
Pages
F136-F140
ISSN
  • 1359-2998 (ISSN-L)
  • 1468-2052
OpenAlex
W2136983630
Cited by
82
References
1
Citations by year
2026: 8 · 2025: 3 · 2024: 5 · 2023: 4 · 2022: 7 · 2021: 10 · 2020: 6 · 2019: 11 · 2018: 7 · 2017: 10 · 2016: 2 · 2015: 4 · 2014: 3 · 2013: 2
FWCI
2.30
Type
journal article
Language
en
Open access
closed
Locations
  • Archives of Disease in Childhood Fetal & Neonatal (publishedVersion)
  • PubMed (publishedVersion)
  • Pure Amsterdam UMC (publishedVersion)
  • Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Funders
National Institute for Health and Care Research (NF-SI-0508-10274)
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Hyperglycemia and glycemic control in critically ill and hospitalized patients
  • Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Infant Development and Preterm Care
Keywords
continuous glucose monitoring, preterm infants, very low birth weight infants, sensor accuracy, hypoglycemia, hyperglycemia, glycemic control, intensive care, point-of-care glucose monitoring, Clarke error grid
MeSH terms
Blood Glucose, Female, Humans, Hyperglycemia, Hypoglycemia, Infant, Newborn, Infant, Premature, Infant, Premature, Diseases, Male, Monitoring, Physiologic, Prospective Studies, Sensitivity and Specificity, Reproducibility of Results, Intensive Care, Neonatal, Point-of-Care Systems, Infant, Very Low Birth Weight

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review