Does visual restitution training change absolute homonymous visual field defects? A fundus controlled study
Open accessThe DOI matches its Crossref record.
Abstract
AIM: To examine whether visual restitution training (VRT) is able to change absolute homonymous field defect, assessed with fundus controlled microperimetry, in patients with hemianopia. METHODS: 17 patients with stable homonymous visual field defects before and after a 6 month VRT period were investigated with a specialised microperimetric method using a scanning laser ophthalmoscope (SLO). Fixation was controlled by SLO fundus monitoring. The size of the field defect was quantified by calculating the ratio of the number of absolute defects and the number of test points; the training effect E was defined as the difference between these two ratios before and after training. A shift of the entire vertical visual field border by 1 degrees would result in an E value of 0.14. RESULTS: The mean training effect of all right eyes was E = 0.025 (SD 0.052) and all left eyes E = 0.008 (SD 0.034). In one eye, a slight non-homonymous improvement along the horizontal meridian occurred. CONCLUSIONS: In one patient, a slight improvement along the horizontal meridian was found in one eye. In none of the patients was an explicit homonymous change of the absolute field defect border observed after training.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evidence-based cognitive rehabilitation: updated review of the literature from 2003 through 2008
Cicerone, K. D., Langenbahn, D. M., Braden, C., Malec, J. F., Kalmar, K., Fraas, M., Felicetti, T., Laatsch, L., Harley, J. P., Bergquist, T., et al. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.11.015 · Cited by 1,599
“Five class III studies(22,23,26,28,29) also investigated the effects of VRT on reducing he extent of visual field deficits, with some evidence that these hanges are associated with subjective improvements in visual unction and reading speed.(26,28,29) patial and Praxic Deficits”
Cowey, A. (2010) · Experimental Brain Research · doi:10.1007/s00221-009-1914-2 · Cited by 279
Digital Therapeutics: Emerging New Therapy for Neurologic Deficits after Stroke
Choi, M. J., Kim, H., Nah, H.-W., & Kang, D.-W. (2019) · Journal of Stroke · doi:10.5853/jos.2019.01963 · Cited by 63
“Furthermore, patients reported a general sense of improved vision such as an improvements in detecting and localizing stimuli, and reading.77 However, the results of these studies were later criticized for the fact that the patients may have developed compensatory eye movements instead of vision restoration, as the VR…”
Method
Metadata
- Authors
- Reinhard, J.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2005-01-01
- Volume
- 89
- Issue
- 1
- Pages
- 30-35
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2128744437
- Cited by
- 213
- References
- 0
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.