Bacterial contamination of ophthalmic solutions used in an extended care facility
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AIM: To assess the frequency of contamination of ophthalmic solutions in a long-term care facility and to describe the characteristics of contaminated solutions. METHODS: One hundred and twenty-three ophthalmic solutions used for patient treatment in a long-term care facility were cultured for bacteria. The culture results were analysed according to the therapeutic class of the solution, how long the bottle had been in use and the appearance of the bottle on visual inspection. RESULTS: 10 (8%) of the 123 multiple-dose solutions were contaminated with bacteria: 4 (50%) of 8 steroid-containing anti-inflammatory solutions, 2 (33%) of 6 combination antimicrobial and steroid-containing anti-inflammatory solutions, 2 (6%) of 34 solutions for treatment of glaucoma, and 2 (4%) of 57 medications for "dry eye". None of the mydriatic, miotic or non-combination antimicrobial solutions was contaminated. Proteus mirabilis was identified in 8 (80%) of the 10 contaminated solutions. Only 30% of the contaminated solution bottles were classified as "dirty" bottles when the bottles were visually inspected. Neither the length of time the solutions had been in use nor the appearance of the bottle predicted contamination. CONCLUSIONS: 8% of ophthalmic solutions used in a long-term care facility were contaminated with bacteria, most frequently Proteus mirabilis. Compared with solutions not containing steroids, steroid solutions were 5.8 times more likely to be contaminated (RR = 5.84, 95% CI: 2.42 to 14.10, p<0.002). The frequent contamination during reuse of certain steroid-containing ophthalmic solutions raises the question of whether single-use solutions might be preferred for these and other classes of ocular drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Contamination of diagnostic ophthalmic solutions in primary eye care settings
Clark, P. J., Ong, B., & Stanley, C. B. (1997) · Military Medicine · doi:10.1093/milmed/162.7.501 · Cited by 35
Cited by
Tsegaw, A., Tsegaw, A., Abula, T., & Assefa, Y. (2017) · Middle East African Journal of Ophthalmology · doi:10.4103/meajo.meajo_308_16 · Cited by 36
Contamination of multi dose eyedrops in the intra and perioperative context
Daehn, T., Schneider, A., Knobloch, J., Hellwinkel, O. J. C., Spitzer, M. S., & Kromer, R. (2021) · Scientific Reports · doi:10.1038/s41598-021-99892-8 · Cited by 26
Somner, J. E. A., Cavanagh, D. J., Wong, K. K. Y., Whitelaw, M., Thomson, T., & Mansfield, D. (2010) · Eye · doi:10.1038/eye.2009.129 · Cited by 23
The reuse of opthalmic minims®: an unacceptable cross-infection risk?
Rautenbach, P., Wilson, A., & Gouws, P. (2010) · Eye · doi:10.1038/eye.2009.39 · Cited by 13
Virani, S., Rewri, P., & Vyas, A. (2016) · Delhi Journal of Ophthalmology · doi:10.7869/djo.164 · Cited by 5
Metadata
- Authors
- Jokl, D. H.-K., Wormser, G. P., Nichols, N. S., Montecalvo, M. A., & Karmen, C. L.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2007-05-02
- Volume
- 91
- Issue
- 10
- Pages
- 1308-1310
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2122332146
- Cited by
- 37
- References
- 1
- FWCI
- 0.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.