Evaluation of optical coherence tomography findings in age-related macular degeneration: a reproducibility study of two independent reading centres
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND/AIMS: To determine the reproducibility among readers of two independent certified centres, the Vienna Reading Center (VRC) and the University of Wisconsin-Madison Reading Center (UW-FPRC) for optical coherence tomography (OCT) images in age-related macular degeneration (AMD). METHODS: Fast macular thickness scans and 6 mm cross hair scans were obtained from 100 eyes with all subtypes of AMD using Stratus OCT. Consensus readings were performed by two certified OCT readers of each reading center using their grading protocol. Common variables of both grading protocols, such as presence of cystoid spaces, subretinal fluid, vitreomacular traction and retinal pigment epithelial detachment, were compared using κ statistics. In addition, the intraclass correlation coefficient (ICC) was calculated for centre point thickness (CPT) of values re-measured manually in the presence of alignment errors. RESULTS: The reproducibility was dependent on the variable measured with a κ value of 0.81 for the presence of cystoid spaces, 0.78 for the presence of subretinal fluid and 0.795 for the presence of vitreomacular traction. The lowest reproducibility was found for the presence of retinal pigment epithelial detachment with a κ value of 0.51. The CPT was re-measured in 29 out of 100 scans at both sites with an ICC of the re-measured thicknesses of 0.92. CONCLUSION: OCT scan data are crucial in monitoring treatment efficacy in AMD clinical trials. For comparison of results obtained by different reading centers, the inter-reading center reproducibility is essential. Although the reproducibility is generally high, the reliability depends on the selected morphological parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Evaluation of Age-related Macular Degeneration With Optical Coherence Tomography
Keane, P. A., Patel, P. J., Liakopoulos, S., Heussen, F. M., Sadda, S. R., & Tufail, A. (2012) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2012.01.006 · Cited by 280
Schmidt-Erfurth, U., Waldstein, S. M., Deak, G.-G., Kundi, M., & Simader, C. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2014.11.017 · Cited by 211
Self-citationRakoczy, E. P., Lai, C.-M., Magno, A. L., Wikstrom, M. E., French, M. A., Pierce, C. M., Schwartz, S. D., Blumenkranz, M. S., Chalberg, T. W., Degli-Esposti, M. A., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)00345-1 · Cited by 189
Simader, C., Ritter, M., Bolz, M., Deák, G. G., Mayr-Sponer, U., Golbaz, I., Kundi, M., & Schmidt-Erfurth, U. M. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2013.12.029 · Cited by 177
“Pigment epithelial detachments were definitely graded if the radial extension of an RPE elevation exceeded 400 mm at the base or the vertical elevation from the RPE band to the surface of the choriocapillaris was >200 mm.(22)”
BackgroundResultSelf-citationDeCroos, F. C., Toth, C. A., Stinnett, S. S., Heydary, C. S., Burns, R., & Jaffe, G. J. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.06.040 · Cited by 67
Metadata
- Authors
- Ritter, M., Elledge, J., Simader, C., Deak, G. G., Benesch, T., Blodi, B. A., & Schmidt-Erfurth, U. M.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2010-08-30
- Volume
- 95
- Issue
- 3
- Pages
- 381-385
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2154519839
- Cited by
- 36
- References
- 0
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of optical coherence tomography findings in age-related macular degeneration: a reproducibility study of two independent reading centres. https://app.cochat.ai/papers/10.1136/bjo.2009.175976
- The paper
- Ritter, M., Elledge, J., Simader, C., Deak, G. G., Benesch, T., Blodi, B. A., & Schmidt-Erfurth, U. M. (2011). Evaluation of optical coherence tomography findings in age-related macular degeneration: a reproducibility study of two independent reading centres. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.2009.175976
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.