Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 404

The DOI matches its Crossref record.

Macular hole size as a prognostic factor in macular hole surgery

Open access
Ullrich, S·2002·British Journal of Ophthalmology

Abstract

BACKGROUND/AIM: In 1991 there was a series of successful closures of a macular hole after vitrectomy and membrane peeling. Today this technique has become a standard procedure. The aim of this study was to evaluate the role of optical coherence tomography in diagnosing and staging, as well as in predicting, the functional and anatomical outcome after macular hole surgery. METHOD: In a prospective study 94 consecutive patients (20 male, 74 female) with a mean age of 67.6 (SD 6.0) years and a macular hole stage II (n = 8), III (n = 72), and IV (n = 14) according to the classification by Gass were examined with optical coherence tomography (OCT) before pars plana vitrectomy. Macular hole diameters were determined at the level of the retinal pigment epithelium (base diameter) and at the minimal extent of the hole (minimum diameter). Calculated hole form factor (HFF) was correlated with the postoperative anatomical success rate and best corrected visual acuity. The duration of symptoms was correlated with base and minimum diameter of the macular hole. RESULTS: In eyes without anatomical closure of the macular hole after one surgical approach (13/94) the base diameter (p1) and the minimum diameter (p2) were significantly larger than in cases with immediate postsurgical closure (p1 = 0.003; p2 = 0.028). There was a significant negative correlation between both the base and the minimum diameter of the hole and the postoperative visual function (p1 = 0.016; p2 = 0.002). In all patients with HFF >0.9 the macular hole was closed following one surgical procedure, whereas in eyes with HFF <0.5 anatomical success rate was 67%. Better postoperative visual outcome correlated with higher HFF (p = 0.050). There was no significant correlation between the duration of symptoms and base or minimum diameters (p1 = 0.053; p2 = 0.164), respectively. CONCLUSION: Preoperative measurement of macular hole size with OCT can provide a prognostic factor for postoperative visual outcome and anatomical success rate of macular hole surgery. The duration of symptoms did not correlate with the diameters measured. Base and minimum diameters especially seem to be of predictive value in macular hole surgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjo.86.4.390

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 404

Metadata

Authors
Ullrich, S.
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
2002-04-01
Volume
86
Issue
4
Pages
390-393
ISSN
0007-1161 (ISSN-L)
OpenAlex
W2152312015
Cited by
404
References
0
FWCI
4.98
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Macular hole size as a prognostic factor in macular hole surgery. https://app.cochat.ai/papers/10.1136/bjo.86.4.390
The paper
Ullrich, S. (2002). Macular hole size as a prognostic factor in macular hole surgery. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.86.4.390

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.