Abstract
Objective: To examine the accuracy of the Caltrac accelerometer for estimating energy expenditure (EE) during three exercise modes. Methods: A subset of 31 women (mean (SEM) age 22.6 (5) years) was selected from a training study comparing various physiological parameters during race walking, running, and stepping. Subjects each performed mode specific graded exercise tests to peak V̇o 2. Regression equations for V̇o 2 v heart rate (HR) were generated from each individual's test data. EE (kcal and kJ) was estimated for each V̇o 2 value based on the respiratory exchange ratio, and kcal v HR regression equations were generated to predict EE from each subject's HR data (EE-HR). HR in the field was monitored by telemetry, and two Caltrac monitors, one set for EE and one to give counts, were attached to a belt over opposite hips. Results: EE-HR was not significantly different across exercise modes. Caltrac overestimated EE (P<0.01) in runners (14%) and walkers (19%) but underestimated EE in steppers by about 10% (P = 0.12). Conclusions: The Caltrac is a reliable instrument but it did not accurately distinguish EE in running, race walking, or stepping in a group of young women.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calorimetric Validation of the Caltrac® Accelerometer during Level Walking
Balogun, J. A., Martin, D. A., & Clendenin, M. A. (1989) · Physical Therapy · doi:10.1093/ptj/69.6.501 · Cited by 57
Cited by
McGrae McDermott, M., Greenland, P., Liu, K., Guralnik, J. M., Criqui, M. H., Dolan, N. C., Chan, C., Celic, L., Pearce, W. H., Schneider, J. R., et al. (2001) · JAMA · doi:10.1001/jama.286.13.1599 · Cited by 856
International Physical Activity Questionnaire: Reliability and Validity of the Turkish Version
Saglam, M., Arikan, H., Savci, S., Inal-Ince, D., Bosnak-Guclu, M., Karabulut, E., & Tokgozoglu, L. (2010) · Perceptual and Motor Skills · doi:10.2466/06.08.pms.111.4.278-284 · Cited by 845
McDermott, M. M., Greenland, P., Liu, K., Guralnik, J. M., Celic, L., Criqui, M. H., Chan, C., Martin, G. J., Schneider, J., Pearce, W. H., et al. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-136-12-200206180-00008 · Cited by 532
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“a range of measures, including direct/indirect calorimetry [467, 469, 470], activity monitoring [80, 146, 174, 401] and”
Background
Metadata
- Authors
- Swan, P. D., Byrnes, W. C., & Haymes, E. M.
- Venue
- British Journal of Sports Medicine
- Publisher
- BMJ
- Published
- 1997-09
- Volume
- 31
- Issue
- 3
- Pages
- 235-239
- ISSN
- 0306-3674 (ISSN-L)
- 1473-0480
- OpenAlex
- W2019368505
- Cited by
- 32
- References
- 1
- FWCI
- 0.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.