CoChat

Cardiovascular screening in adolescents and young adults: a prospective study comparing the Pre-participation Physical Evaluation Monograph 4th Edition and ECG

Open access
Fudge, Jessie, Harmon, Kimberly G, Owens, David S, Prutkin, Jordan M, Salerno, Jack C, Asif, Irfan M, Haruta, Alison, Pelto, Hank, Rao, Ashwin L, Toresdahl, Brett G, Drezner, Jonathan A · 2014 · British Journal of Sports Medicine
Cited by 108

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: This study compares the accuracy of cardiovascular screening in active adolescents and young adults using a standardised history, physical examination and resting 12-lead ECG. Methods: Participants were prospectively screened using a standardised questionnaire based on the Pre-participation Physical Evaluation Monograph 4th Edition (PPE-4), physical examination and ECG interpreted using modern standards. Participants with abnormal findings had focused echocardiography and further evaluation. Primary outcomes included disorders associated with sudden cardiac arrest (SCA). Results: From September 2010 to July 2011, 1339 participants underwent screening: age 13–24 (mean 16) years, 49% male, 68% Caucasian, 17% African-American and 1071 (80%) participating in organised sports. Abnormal history responses were reported on 916 (68%) questionnaires. After physician review, 495/916 (54%) participants with positive questionnaires were thought to have non-cardiac symptoms and/or a benign family history and did not warrant additional evaluation. Physical examination was abnormal in 124 (9.3%) participants, and 72 (5.4%) had ECG abnormalities. Echocardiograms were performed in 586 (44%) participants for abnormal history (31%), physical examination (8%) or ECG (5%). Five participants (0.4%) were identified with a disorder associated with SCA, all with ECG-detected Wolff-Parkinson-White. The false-positive rates for history, physical examination and ECG were 31.3%, 9.3% and 5%, respectively. Conclusions: A standardised history and physical examination using the PPE-4 yields a high false-positive rate in a young active population with limited sensitivity to identify those at risk for SCA. ECG screening has a low false-positive rate using modern interpretation standards and improves detection of primary electrical disease at risk of SCA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjsports-2014-093840

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 108

Metadata

Authors
Fudge, J., Harmon, K. G., Owens, D. S., Prutkin, J. M., Salerno, J. C., Asif, I. M., Haruta, A., Pelto, H., Rao, A. L., Toresdahl, B. G., & Drezner, J. A.
Venue
British Journal of Sports Medicine
Publisher
BMJ
Published
2014-06-19
Volume
48
Issue
15
Pages
1172-1178
ISSN
  • 0306-3674 (ISSN-L)
  • 1473-0480
OpenAlex
W2000707238
Cited by
108
References
4
FWCI
8.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cardiovascular screening in adolescents and young adults: a prospective study comparing the Pre-participation Physical Evaluation Monograph 4th Edition and ECG. https://app.cochat.ai/papers/10.1136/bjsports-2014-093840
The paper
Fudge, J., Harmon, K. G., Owens, D. S., Prutkin, J. M., Salerno, J. C., Asif, I. M., Haruta, A., Pelto, H., Rao, A. L., Toresdahl, B. G., & Drezner, J. A. (2014). Cardiovascular screening in adolescents and young adults: a prospective study comparing the Pre-participation Physical Evaluation Monograph 4th Edition and ECG. British Journal of Sports Medicine. https://doi.org/10.1136/bjsports-2014-093840

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.