CoChat

Screening for thyroid dysfunction in diabetics.

Open access
Feely, J, Isles, T E · 1979 · BMJ
Cited by 116

The DOI matches its Crossref record.

Abstract

Background: Rigid bronchoscopy yields a unique challenge for mechanical ventilation. An uncuffed and rigid bronchoscope requires mechanical ventilation strategies not often used. Manual jet ventilation is the most common approach and gold standard. At our hospital, we previously used either manual jet or an LTV-1200 ventilator during rigid bronchoscopy. We recently started using the Philips Respironics V60 ventilator because of its capabilities to ventilate with a leak. The rigid bronchoscopy cases subjectively had better and more stable ventilation. The purpose of this study was to perform a bench evaluation of various leak conditions comparing the V60 to the manual jet for ventilation during simulated rigid bronchoscopy. Methods: We performed a bench evaluation of rigid bronchoscopy with an intubation mannikin airway attached to the Ingmar ASL-5000 test lung with a Novametrix NM3-NICO flow sensor between the mannikin airway and the ASL-5000. Normal apneic adult settings were used on the ASL-5000. The manual jet was tested at 40 and 60 PSI with two breath types, "Burst" - shortest but full actuation of the jet valve and "Hold" - full actuation until inspiration ended. The V60 was tested with I-Times of 0.6 seconds and 1 second, with a delta pressure of 20cm H2O and 30 cm H2O. Two different leak scenarios were tested: "Low Leak" - typical setup of the rigid bronchoscope with the silicon cap in place. "High Leak" - setup without silicon cap in place. Inspiratory tidal volume was collected with each of the different scenario combinations with the NM3 device. Results: See graphic for the results of the inspiratory volume delivered with each device for the different scenarios. Conclusions: While the manual jet produced similar results regardless of leak it also produced the widest variation in tidal volumes: volumes that would be too low to maintain stable gas exchange ("burst" breaths) and large tidal volumes that could cause lung injury ("hold" breaths). This is dependent on the duration of the actuation of the manual jet with no user feedback for breaths that are too large. The V60 produced reasonable breaths during low leak (~300 to 500 mL) and dropped to ~100 mL during high leak. The results of this bench show that the V60 may be better from a lung injury standpoint and should support the patient through rigid bronchoscopy if high leak situations are kept short.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.1.6179.1678

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Feely, J., & Isles, T. E.
Venue
BMJ
Publisher
BMJ
Published
1979-06-23
Volume
1
Issue
6179
Pages
1678-1678
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2032102154
Cited by
116
References
0
FWCI
1.83
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.