Does prophylactic thyroxine treatment after operation for non-toxic goitre influence thyroid size?
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In order to evaluate the influence of thyroxine treatment on thyroid volume after thyroidectomy for non-toxic goitre 110 consecutive patients were randomised to receive thyroxine (150 micrograms daily) or no treatment three months after operation. Thyroid volume determined by ultrasonography did not differ significantly between the two groups one year after operation. Nevertheless, a similar decrease in volume was seen from three to 12 months postoperatively in the thyroxine treated and no treatment groups (median 18 (range 8-70) ml to 16 (range 7-57) ml, and median 20 (range 9-72) ml to 17 (range 8-58) ml, respectively). Three patients (two given thyroxine) had recurrence of goitre within the observation period of one year. In this series thyroid volume decreased during the first postoperative year independently of thyroxine treatment. Hence it seems questionable whether postoperative thyroid function studies can identify patients at risk of recurrence of goitre after operation for non-toxic goitre and whether routine postoperative treatment with thyroxine is justifiable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Pituitary-Thyroid Axis after Hemithyroidectomy in Euthyroid Man
MATTE, R., STE-MARIE, L. G., COMTOIS, R., D'AMOUR, P., LACROIX, A., CHARTRAND, R., POISSON, R., & BASTOMSKY, C. H. (1981) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-53-2-377 · Cited by 29
Cited by
Evaluation and Management of the Solid Thyroid Nodule
Burch, H. B. (1995) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/s0889-8529(18)30019-7 · Cited by 212
Papini, E., Petrucci, L., Guglielmi, R., Panunzi, C., Rinaldi, R., Bacci, V., Crescenzi, A., Nardi, F., Fabbrini, R., & Pacella, C. M. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.3.4615 · Cited by 194
Radioiodine treatment of multinodular non-toxic goitre.
Nygaard, B., Hegedüs, L., Gervil, M., Hjalgrim, H., Søe-Jensen, P., & Hansen, J. M. (1993) · BMJ · doi:10.1136/bmj.307.6908.828 · Cited by 173
Self-citationWesche, M. F. T. (2001) · Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.86.3.998 · Cited by 168
Pappalardo, G., Guadalaxara, A., Frattaroli, F. M., Illomei, G., & Falaschi, P. (2003) · European Journal of Surgery · doi:10.1080/110241598750005840 · Cited by 163
Thyroxine Suppressive Therapy in Patients with Nodular Thyroid Disease
Gharib, H., & Mazzaferri, E. L. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-5-199803010-00008 · Cited by 163
Thyroid hormone replacement after thyroid lobectomy
Stoll, S. J., Pitt, S. C., Liu, J., Schaefer, S., Sippel, R. S., & Chen, H. (2009) · Surgery · doi:10.1016/j.surg.2009.06.026 · Cited by 150
Medici, B. B., Nygaard, B., la Cour, J. L., Grand, M. K., Siersma, V., Nicolaisdottir, D. R., Lind, B., Olivarius, N. D. F., & Andersen, C. L. (2019) · Thyroid® · doi:10.1089/thy.2018.0539 · Cited by 63
Metadata
- Authors
- Hegedus, L., Hansen, J. M., Veiergang, D., & Karstrup, S.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 1987-03-28
- Volume
- 294
- Issue
- 6575
- Pages
- 801-803
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2121328632
- Cited by
- 61
- References
- 1
- FWCI
- 3.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.