CoChat

Radiology services for remote communities: cost minimisation study of telemedicine

Open access
Halvorsen, Peder Andreas, Kristiansen, Ivar Sonbo · 1996 · BMJ
Cited by 71

The DOI matches its Crossref record.

Abstract

Objectives : To determine the social costs of providing a rural population with radiology services under three different systems: the existing system (a small x ray unit at the remote site and all other examinations at the nearest radiology department (the host site)); a teleradiology system (most examinations at the remote site and more advanced examinations at the host site); and all examinations at the host site. Design : Cost minimisation study. Setting : Primary health care in a remote community in Norway. Subjects : A randomly selected sample (n=597) of all patients (n=1793) having radiological examinations in 1993. Main outcome measures : Annual direct medical costs, direct non-medical (travel) costs, and indirect costs (lost production) of the three options. Results : After exclusion of costs common to the three systems the direct medical, direct non-medical, and indirect costs of the three options were, respectively, £9000, £51 000, and £31 500 (total £91 500) for the existing system; £108 000, £2000, and £13 500 (total £123 500) for the teleradiology option; and £0, £75 000, and £42 000 (£117 000 in total) for the “all at host” option. Sensitivity analyses indicated that the existing system is the least costly option except when lost leisure is valued as highly as lost production. Conclusion : The teleradiology option did not seem to be cost saving in the study community. Such systems, however, may be justified on the grounds of equity of access and quality of care. Key messages: Few, if any, studies of the cost effectiveness of this technology have been published This study indicates that in remote primary health care, teleradiology is not less costly than conventional technologies Teleradiology may be justified as a means to increase equity in access to high quality health care in remote communities The subject calls for further studies in other countries

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.312.7042.1333

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 42

  1. Hillman, 1994, Outcomes research and cost-effectiveness analysis for diagnostic imaging, Radiology, 193, 307, 10.1148/radiology.193.2.7972731 · doi:10.1148/radiology.193.2.7972731
  2. 10.1016/0720-048X(92)90122-P · DOI
  3. Little AD . Telecommunications: can it help solve America's health care problems? Cambridge: Arthur D Little, 1992.
  4. Barnes, 1993, Computers for clinical practice and education in radiology, Radiographics, 13, 673, 10.1148/radiographics.13.3.8316673 · DOI
  5. Gitlin, 1986, Teleradiology, Radiol Clin North Am, 24, 55, 10.1016/S0033-8389(22)01055-7 · doi:10.1016/s0033-8389(22)01055-7
  6. Drummond MF Stoddart GL Torrance GW . Methods for the economic evaluation of health care programmes. Oxford: Oxford Medical Publications, 1987.
  7. Ackerman, 1993, High performance computing and communications, Radiographics, 13, 1129, 10.1148/radiographics.13.5.8210594 · doi:10.1148/radiographics.13.5.8210594
  8. Scott, 1993, Subtle orthopedic fractures: teleradiology workstation versus film interpretation, Radiology, 187, 811, 10.1148/radiology.187.3.8497636 · DOI
  9. Goodman, 1986, Digital and conventional chest images: observer performance with film digital radiography system, Radiology, 158, 27, 10.1148/radiology.158.1.3940392 · doi:10.1148/radiology.158.1.3940392
  10. Wegryn, 1990, Comparison of digital and conventional musculoskeletal radiography: an observer performance study, Radiology, 175, 225, 10.1148/radiology.175.1.2315485 · doi:10.1148/radiology.175.1.2315485
  11. Arrildt, 1994, The cost of high-tech care, Radiology, 190, 41, 10.1148/radiology.190.2.41a · doi:10.1148/radiology.190.2.41a
  12. Ill, 1991, Teleradiology: costs of hardware and communications, AJR Am J Roentgenol, 156, 1279, 10.2214/ajr.156.6.2028879 · doi:10.2214/ajr.156.6.2028879
  13. Batnitzky, 1995, Teleradiology: an assessment, Radiology, 177, 11, 10.1148/radiology.177.1.2204957 · doi:10.1148/radiology.177.1.2204957
  14. Olsen, 1994, Production gains: should they count in health care evaluation?, Scottish Journal of Political Economy, 41, 69, 10.1111/j.1467-9485.1994.tb01111.x · doi:10.1111/j.1467-9485.1994.tb01111.x
  15. Sharp C . Developments in transport policy in United Kingdom. Journal of Transport and Economics Policy 1988; 235–8.
  16. 10.1007/BF02011480 · DOI
  17. Goldberg, 1993, New high-resolution teleradiology system: prospective study of diagnostic accuracy in 685 transmitted clinical cases, Radiology, 186, 429, 10.1148/radiology.186.2.8421746 · DOI
  18. 10.1097/00004424-199209000-00016 · doi:10.1097/00004424-199209000-00016
  19. Hayrapetian, 1989, Comparison of 2,048 line digital display formats and conventional radiographs: an ROC study, Am J Roentgenol, 152, 1113, 10.2214/ajr.152.5.1113 · doi:10.2214/ajr.152.5.1113
  20. Chakraborty, 1986, Digital and conventional chest imaging: a modified ROC study of observer performance using simulated nodules, Radiology, 158, 35, 10.1148/radiology.158.1.3940394 · doi:10.1148/radiology.158.1.3940394
  21. Huebener, 1983, Scanned projection radiography of the chest versus standard film radiography: a comparison of 250 cases, Radiology, 148, 363, 10.1148/radiology.148.2.6867326 · doi:10.1148/radiology.148.2.6867326
  22. Ackerman, 1993, Receiver operating characteristic analysis of fracture and pneumonia detection: comparison of laser-digitized workstation images and conventional analog radiographs, Radiology, 186, 263, 10.1148/radiology.186.1.8416576 · doi:10.1148/radiology.186.1.8416576
  23. Yoshino, 1992, Diagnostic performance of teleradiology in cervical spine fracture detection, Invest Radiol, 27, 55, 10.1097/00004424-199201000-00011 · DOI
  24. Slasky, 1990, Receiver operating characteristic analysis of chest image interpretation with conventional, laser-printed, and high-resolution workstation images, Radiology, 174, 775, 10.1148/radiology.174.3.2305061 · DOI
  25. Cox, 1990, Chest radiography: comparison of high-resolution digital displays with conventional and digital film, Radiology, 176, 771, 10.1148/radiology.176.3.2389035 · doi:10.1148/radiology.176.3.2389035
  26. MacMahon, 1988, Digital chest radiography: effect on diagnostic accuracy of hard copy, conventional video, and reversed gray scale video display formats, Radiology, 168, 669, 10.1148/radiology.168.3.3406396 · doi:10.1148/radiology.168.3.3406396
  27. Lams, 1986, Spatial resolution requirements for digital chest radiographs: an ROC study of observer performance in selected cases, Radiology, 158, 11, 10.1148/radiology.158.1.3940365 · doi:10.1148/radiology.158.1.3940365
  28. MacMahon, 1986, Digital radiography of subtle pulmonary abnormalities: an ROC study of the effect of pixel size on observer performance, Radiology, 158, 21, 10.1148/radiology.158.1.3940383 · DOI
  29. Murphey, 1990, Nondisplaced fractures: spatial resolution requirements for detection with digital skeletal imaging, Radiology, 174, 865, 10.1148/radiology.174.3.2305071 · doi:10.1148/radiology.174.3.2305071
  30. Seeley, 1987, Total digital radiology department: spatial resolution requirements, Am J Roentgenol, 148, 421, 10.2214/ajr.148.2.421 · doi:10.2214/ajr.148.2.421
  31. Markivee, 1990, Teleradiology image transmission system: diagnostic accuracy at three matrix sizes for various types of images, J Digit Imaging, 3, 170, 10.1007/BF03167603 · doi:10.1007/bf03167603
  32. Bidgood, 1992, Understanding and using teleradiology, Semin Ultrasound CT MR, 13, 102
  33. Goodman, 1988, Digital radiography of the chest: promises and problems, Am J Roentgenol, 150, 1241, 10.2214/ajr.150.6.1241 · doi:10.2214/ajr.150.6.1241
  34. Fraser, 1989, Digital imaging of the chest, Radiology, 171, 297, 10.1148/radiology.171.2.2649913 · doi:10.1148/radiology.171.2.2649913
  35. Kundel, 1986, Visual perception and image display terminals, Radiol Clin North Am, 24, 69, 10.1016/S0033-8389(22)01056-9 · doi:10.1016/s0033-8389(22)01056-9
  36. Schaefer, 1991, Interstitial lung disease: impact of postprocessing in digital storage phosphor imaging, Radiology, 178, 733, 10.1148/radiology.178.3.1994410 · doi:10.1148/radiology.178.3.1994410
  37. Dwyer, 1992, Performance characteristics and image fidelity of gray-scale monitors, Radiographics, 12, 765, 10.1148/radiographics.12.4.1636038 · doi:10.1148/radiographics.12.4.1636038
  38. Templeton, 1991, A dial-up digital teleradiology system: technical considerations and clinical experience, Am J Roentgenol, 157, 1331, 10.2214/ajr.157.6.1950884 · doi:10.2214/ajr.157.6.1950884
  39. Fryback, 1983, A conceptual model for output measures in cost-effectiveness evaluation of diagnostic imaging, J Neuroradiol, 10, 94
  40. Fryback, 1991, The efficacy of diagnostic imaging, ?? Making, 11, 88
  41. Larsen, 1994, Status of radiology in Norway, Tidsskr Nor Laegeforen, 114, 2934
  42. Schroeder, 1995, Physician shortages in rural America, Lancet, 345, 1001, 10.1016/S0140-6736(95)90753-X · doi:10.1016/s0140-6736(95)90753-x

Cited by

See all 71

Metadata

Authors
Halvorsen, P. A., & Kristiansen, I. S.
Venue
BMJ
Publisher
BMJ
Published
1996-05-25
Volume
312
Issue
7042
Pages
1333-1336
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2006549440
Cited by
71
References
0
FWCI
7.34
Type
journal article
Language
en
Open access
green
Licence
www.bmj.com/company/legal-information/terms-conditions/legal-information/tdm-licencepolicy (tdm)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Radiology services for remote communities: cost minimisation study of telemedicine. https://app.cochat.ai/papers/10.1136/bmj.312.7042.1333
The paper
Halvorsen, P. A., & Kristiansen, I. S. (1996). Radiology services for remote communities: cost minimisation study of telemedicine. BMJ. https://doi.org/10.1136/bmj.312.7042.1333

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.