CoChat

Population based randomised study of uptake and yield of screening by flexible sigmoidoscopy compared with screening by faecal occult blood testing

Open access
Verne, Julia E C W, Aubrey, Roger, Love, Sharon B, Talbot, Ian C, Northover, John M A · 1998 · BMJ
Cited by 91

The DOI matches its Crossref record.

Abstract

Objectives: To compare the feasibility of mass screening by flexible sigmoidoscopy with screening by faecal occult blood testing (Haemoccult) and both tests combined. Design: Patients were randomised to screening by flexible sigmoidoscopy, faecal blood testing, or both tests. The flexible sigmoidoscopy examinations were performed by a general practitioner. Setting : General practice. Subjects : 3744 patients aged 50-75 years. Main outcome measures : Uptake, positive results, detection of neoplasia, complications, and recall for diagnostic colonoscopy. Results: Uptake was significantly higher in the flexible sigmoidoscopy group (46.6%) than in the faecal blood test group (31.6%; P<0.001) or than in the group having both tests (30.1%; P<0.001). Telephone reminders increased uptake of sigmoidoscopy to 61.8%. In total, 1116 sigmoidoscopy examinations were performed without major complication. Polyps were found in 19.3% (95% confidence interval 17.0% to 21.6%) but only 6.8% (5.3% to 8.3%) had adenomas and 2.4% (1.5% to 3.3%) “high risk” adenomas. Cancer was detected in four subjects. The faecal blood test yielded positive results in 0.8% (0.2% to 1.4%) but missed at least one cancer and 30 cases of adenoma which were found by sigmoidoscopy in the combined group. Use of histological criteria—shown elsewhere to correlate with future risk of colorectal cancer —to select “positive” patients could reduce recall for diagnostic colonoscopy from about 20% to less than 5%. Conclusions: Some of the predicted obstacles to screening with flexible sigmoidoscopy are surmountable. Clear evidence relating to efficacy will be obtained only from a randomised controlled trial.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.317.7152.182

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Metadata

Authors
Verne, J. E. C. W., Aubrey, R., Love, S. B., Talbot, I. C., & Northover, J. M. A.
Venue
BMJ
Publisher
BMJ
Published
1998-07-18
Volume
317
Issue
7152
Pages
182-185
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2094073090
Cited by
91
References
0
FWCI
2.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Population based randomised study of uptake and yield of screening by flexible sigmoidoscopy compared with screening by faecal occult blood testing. https://app.cochat.ai/papers/10.1136/bmj.317.7152.182
The paper
Verne, J. E. C. W., Aubrey, R., Love, S. B., Talbot, I. C., & Northover, J. M. A. (1998). Population based randomised study of uptake and yield of screening by flexible sigmoidoscopy compared with screening by faecal occult blood testing. BMJ. https://doi.org/10.1136/bmj.317.7152.182

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.