Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 230

The DOI matches its Crossref record.

D-dimer testing as an adjunct to ultrasonography in patients with clinically suspected deep vein thrombosis: prospective cohort study

Open access
Bernardi, Enrico, Prandoni, Paolo, Lensing, Anthonie W A, Agnelli, Giancarlo, Guazzaloca, Giuliana, Scannapieco, Gianluigi, Piovella, Franco, Verlato, Fabio, Tomasi, Cristina, Moia, Marco, Scarano, Luigi, Girolami, Antonio · 1998 · BMJ

Abstract

Objective To investigate the efficacy of using a rapid plasma D-dimer test as an adjunct to compression ultrasound for diagnosing clinically suspected deep vein thrombosis. Design D-dimer concentrations were determined in all patients with a normal ultrasonogram at presentation. Repeat ultrasonography was performed 1 week later only in patients with abnormal D-dimer test results. Main outcome measure Patients with normal ultrasonograms were not treated with anticoagulants and were followed for 3 months for thromboembolic complications. Setting University research and affiliated centres. Subjects 946 patients with clinically suspected deep vein thrombosis. Results Ultrasonograms were abnormal at presentation in 260 (27.5%) patients. Of the remaining 686 patients tested for D-dimer, 88 (12.8%) had abnormal concentrations. During follow up venous thromboembolic complications occurred in one of the 598 patients who were not treated with anticoagulants and who had an initial normal ultrasonogram and D-dimer concentration, whereas thromboembolic complications occurred in two of the 83 untreated patients who had abnormal D-dimer concentrations but a normal repeat ultrasonogram. The cumulative incidence of venous thromboembolic complications during follow up was 0.4% (95% confidence interval 0% to 0.9%). The rapid plasma D-dimer test used as an adjunct to compression ultrasonography resulted in a reduction in the mean number of repeat ultrasound examinations and additional hospital visits from 0.7 to 0.1 per patient. Conclusions Testing for D-dimer as an adjunct to a normal baseline ultrasound examination decreased the number of subsequent ultrasound examinations considerably without any increased risk of venous thromboembolic complications in patients not receiving anticoagulants. The use of ultrasound and testing for D-dimer enabled treatment decisions to be made at the time of presentation in most patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.317.7165.1037

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 230

Metadata

Authors
Bernardi, E., Prandoni, P., Lensing, A. W. A., Agnelli, G., Guazzaloca, G., Scannapieco, G., Piovella, F., Verlato, F., Tomasi, C., Moia, M., Scarano, L., & Girolami, A.
Venue
BMJ
Publisher
BMJ
Published
1998-10-17
Volume
317
Issue
7165
Pages
1037-1040
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2132497978
Cited by
230
References
0
FWCI
10.65
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: D-dimer testing as an adjunct to ultrasonography in patients with clinically suspected deep vein thrombosis: prospective cohort study. https://app.cochat.ai/papers/10.1136/bmj.317.7165.1037
The paper
Bernardi, E., Prandoni, P., Lensing, A. W. A., Agnelli, G., Guazzaloca, G., Scannapieco, G., Piovella, F., Verlato, F., Tomasi, C., Moia, M., Scarano, L., & Girolami, A. (1998). D-dimer testing as an adjunct to ultrasonography in patients with clinically suspected deep vein thrombosis: prospective cohort study. BMJ. https://doi.org/10.1136/bmj.317.7165.1037

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.