D-dimer testing as an adjunct to ultrasonography in patients with clinically suspected deep vein thrombosis: prospective cohort study
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Objective To investigate the efficacy of using a rapid plasma D-dimer test as an adjunct to compression ultrasound for diagnosing clinically suspected deep vein thrombosis. Design D-dimer concentrations were determined in all patients with a normal ultrasonogram at presentation. Repeat ultrasonography was performed 1 week later only in patients with abnormal D-dimer test results. Main outcome measure Patients with normal ultrasonograms were not treated with anticoagulants and were followed for 3 months for thromboembolic complications. Setting University research and affiliated centres. Subjects 946 patients with clinically suspected deep vein thrombosis. Results Ultrasonograms were abnormal at presentation in 260 (27.5%) patients. Of the remaining 686 patients tested for D-dimer, 88 (12.8%) had abnormal concentrations. During follow up venous thromboembolic complications occurred in one of the 598 patients who were not treated with anticoagulants and who had an initial normal ultrasonogram and D-dimer concentration, whereas thromboembolic complications occurred in two of the 83 untreated patients who had abnormal D-dimer concentrations but a normal repeat ultrasonogram. The cumulative incidence of venous thromboembolic complications during follow up was 0.4% (95% confidence interval 0% to 0.9%). The rapid plasma D-dimer test used as an adjunct to compression ultrasonography resulted in a reduction in the mean number of repeat ultrasound examinations and additional hospital visits from 0.7 to 0.1 per patient. Conclusions Testing for D-dimer as an adjunct to a normal baseline ultrasound examination decreased the number of subsequent ultrasound examinations considerably without any increased risk of venous thromboembolic complications in patients not receiving anticoagulants. The use of ultrasound and testing for D-dimer enabled treatment decisions to be made at the time of presentation in most patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hemostasis and Thrombosis: Basic Principles and Clinical Practice.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-504_7 · Cited by 1,854
Value of assessment of pretest probability of deep-vein thrombosis in clinical management
Wells, P. S., Anderson, D. R., Bormanis, J., Guy, F., Mitchell, M., Gray, L., Clement, C., Robinson, K. S., & Lewandowski, B. (1997) · The Lancet · doi:10.1016/s0140-6736(97)08140-3 · Cited by 1,229
Detection of Deep-Vein Thrombosis by Real-Time B-Mode Ultrasonography
Lensing, A. W. A., Prandoni, P., Brandjes, D., Huisman, P. M., Vigo, M., Tomasella, G., Krekt, J., ten Cate, J. W., Huisman, M. V., & Büller, H. R. (1989) · New England Journal of Medicine · doi:10.1056/nejm198902093200602 · Cited by 875
Self-citationAccuracy of clinical assessment of deep-vein thrombosis
Wells, P., Hirsh, J., Anderson, D., Lensing, A. A., Foster, G., Kearon, C., Weitz, J., D'Ovidio, R., Cogo, A., Prandoni, P., et al. (1995) · The Lancet · doi:10.1016/s0140-6736(95)92535-x · Cited by 798
Self-citationNoninvasive Diagnosis of Deep Venous Thrombosis
Kearon, C., Julian, J. A., Math, M., Newman, T. E., & Ginsberg, J. S. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-8-199804150-00011 · Cited by 690
Cogo, A., Lensing, A. W. A., Koopman, M. M. W., Piovella, F., Siragusa, S., Wells, P. S., Villalta, S., Büller, H. R., Turpie, A. G. G., & Prandoni, P. (1998) · BMJ · doi:10.1136/bmj.316.7124.17 · Cited by 406
Self-citationBirdwell, B. G., Raskob, G. E., Whitsett, T. L., Durica, S. S., Comp, P. C., George, J. N., Tytle, T. L., & McKee, P. A. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-1-199801010-00001 · Cited by 286
Wells, P. S., Brill-Edwards, P., Stevens, P., Panju, A., Patel, A., Douketis, J., Massicotte, M. P., Hirsh, J., Weitz, J. I., Kearon, C., et al. (1995) · Circulation · doi:10.1161/01.cir.91.8.2184 · Cited by 226
D-dimer testing and acute venous thromboembolism. A shortcut to accurate diagnosis?
Becker, D. M. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.156.9.939 · Cited by 156
Cited by
10-year follow-up of intensive glucose control in type 2 diabetes
Holman, R. R., Paul, S. K., Bethel, M. A., Matthews, D. R., & Neil, H. A. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0806470 · Cited by 7,751
Bates, S. M., Jaeschke, R., Stevens, S. M., Goodacre, S., Wells, P. S., Stevenson, M. D., Kearon, C., Schunemann, H. J., Crowther, M., Pauker, S. G., et al. (2012) · Chest · doi:10.1378/chest.11-2299 · Cited by 686
Lim, W., Le Gal, G., Bates, S. M., Righini, M., Haramati, L. B., Lang, E., Kline, J. A., Chasteen, S., Snyder, M., Patel, P., et al. (2018) · Blood Advances · doi:10.1182/bloodadvances.2018024828 · Cited by 418
Goodacre, S., Sampson, F., Thomas, S., van Beek, E., & Sutton, A. (2005) · BMC Medical Imaging · doi:10.1186/1471-2342-5-6 · Cited by 376
Bernardi, E. (2008) · JAMA · doi:10.1001/jama.300.14.1653 · Cited by 322
Self-citation
Metadata
- Authors
- Bernardi, E., Prandoni, P., Lensing, A. W. A., Agnelli, G., Guazzaloca, G., Scannapieco, G., Piovella, F., Verlato, F., Tomasi, C., Moia, M., Scarano, L., & Girolami, A.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 1998-10-17
- Volume
- 317
- Issue
- 7165
- Pages
- 1037-1040
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2132497978
- Cited by
- 230
- References
- 9
- FWCI
- 10.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.