The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Temperature measured at the axilla compared with rectum in children and young people: systematic review
Open accessAbstract
OBJECTIVE: To evaluate the agreement between temperature measured at the axilla and rectum in children and young people. DESIGN: A systematic review of studies comparing temperature measured at the axilla (test site) with temperature measured at the rectum (reference site) using the same type of measuring device at both sites in each patient. Devices were mercury or electronic thermometers or indwelling thermocouple probes. STUDIES REVIEWED: 40 studies including 5528 children and young people from birth to 18 years. DATA EXTRACTION: Difference in temperature readings at the axilla and rectum. RESULTS: 20 studies (n=3201 (58%) participants) had sufficient data to be included in a meta-analysis. There was significant residual heterogeneity in both mean differences and sample standard deviations within the groups using different devices and within age groups. The pooled (random effects) mean temperature difference (rectal minus axillary temperature) for mercury thermometers was 0.25 degrees C (95% limits of agreement -0.15 degrees C to 0.65 degrees C) and for electronic thermometers was 0. 85 degrees C (-0.19 degrees C to 1.90 degrees C). The pooled (random effects) mean temperature difference (rectal minus axillary temperature) for neonates was 0.17 degrees C (-0.15 degrees C to 0. 50 degrees C) and for older children and young people was 0.92 degrees C (-0.15 degrees C to 1.98 degrees C). CONCLUSIONS: The difference between temperature readings at the axilla and rectum using either mercury or electronic thermometers showed wide variation across studies. This has implications for clinical situations where temperature needs to be measured with precision.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Meta-analysis in clinical trials
DerSimonian, R., & Laird, N. (1986) · Controlled Clinical Trials · doi:10.1016/0197-2456(86)90046-2 · Cited by 39,552
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Hughes, W. T., Armstrong, D., Bodey, G. R., Feld, R., Mandell, G. L., Meyers, J. D., Pizzo, P. A., Schimpff, S. C., Shenep, J. L., Wade, J. C., et al. (1990) · Journal of Infectious Diseases · doi:10.1093/infdis/161.3.381 · Cited by 403
Temperature measurement in term and preterm neonates
Mayfield, S., Bhatia, J., Nakamura, K. T., Rios, G. R., & Bell, E. F. (1984) · The Journal of Pediatrics · doi:10.1016/s0022-3476(84)81011-2 · Cited by 127
Comparison of rectal, axillary, and tympanic membrane temperatures in infants and young children
Muma, B. K., Treloar, D. J., Wurmlinger, K., Peterson, E., & Vitae, A. (1991) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(05)81116-3 · Cited by 116
Axillary and rectal temperature measurements in infants.
Morley, C. J., Hewson, P. H., Thornton, A. J., & Cole, T. J. (1992) · Archives of Disease in Childhood · doi:10.1136/adc.67.1.122 · Cited by 113
Accuracy of infrared ear thermometry and traditional temperature methods in young children.
Erickson, R. S., & Woo, T. M. (1994) · PubMed · Cited by 77
National survey of pediatric fever management practices among emergency department nurses.
Thomas, V., Riegel, B. J., Andrea, J., Murray, P., Gerhart, A. E., & Gocka, I. (1994) · PubMed · Cited by 27
Screening for a raised rectal temperature in Africa.
Jones, R. J., O’Dempsey, T., & Greenwood, B. M. (1993) · Archives of Disease in Childhood · doi:10.1136/adc.69.4.437 · Cited by 13
Cited by
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
Wiebe, N., Vandermeer, B., Platt, R. W., Klassen, T. P., Moher, D., & Barrowman, N. J. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.08.017 · Cited by 296
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Surveillance for ocular hypertension: an evidence synthesis and economic evaluation.
Burr, J., Botello-Pinzon, P., Takwoingi, Y., Hernández, R., Vazquez-Montes, M., Elders, A., Asaoka, R., Banister, K., van der Schoot, J., Fraser, C., et al. (2012) · Health Technology Assessment · doi:10.3310/hta16290 · Cited by 180
Hay, A. D., Costelloe, C., Redmond, N. M., Montgomery, A. A., Fletcher, M., Hollinghurst, S., & Peters, T. J. (2008) · BMJ · doi:10.1136/bmj.a1302 · Cited by 168
“The mean temperatures in the graph are lower than might be expected biologically. This could be explained by the choice of axillary thermometry, which is known to record temperatures around 0.8°C lower than rectal digital thermometers,”
BackgroundInfluential
Metadata
- Authors
- Craig, J. V.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2000-04-29
- Volume
- 320
- Issue
- 7243
- Pages
- 1174-1178
- ISSN
- 0959-8138 (ISSN-L)
- OpenAlex
- W2161632975
- Cited by
- 264
- References
- 10
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temperature measured at the axilla compared with rectum in children and young people: systematic review. https://app.cochat.ai/papers/10.1136/bmj.320.7243.1174
- The paper
- Craig, J. V. (2000). Temperature measured at the axilla compared with rectum in children and young people: systematic review. BMJ. https://doi.org/10.1136/bmj.320.7243.1174
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.