Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 241

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Accuracy of mean arterial pressure and blood pressure measurements in predicting pre-eclampsia: systematic review and meta-analysis

Open access
Cnossen, Jeltsje S, Vollebregt, Karlijn C, Vrieze, Nynke de, Riet, Gerben ter, Mol, Ben W J, Franx, Arie, Khan, Khalid S, Post, Joris A M van der·2008·BMJ

Abstract

OBJECTIVE: To determine the accuracy of using systolic and diastolic blood pressure, mean arterial pressure, and increase of blood pressure to predict pre-eclampsia. DESIGN: Systematic review with meta-analysis of data on test accuracy. DATA SOURCES: Medline, Embase, Cochrane Library, Medion, checking reference lists of included articles and reviews, contact with authors. Review methods Without language restrictions, two reviewers independently selected the articles in which the accuracy of blood pressure measurement during pregnancy was evaluated to predict pre-eclampsia. Data were extracted on study characteristics, quality, and results to construct 2x2 tables. Summary receiver operating characteristic curves and likelihood ratios were generated for the various levels and their thresholds. RESULTS: 34 studies, testing 60 599 women (3341 cases of pre-eclampsia), were included. In women at low risk for pre-eclampsia, the areas under the summary receiver operating characteristic curves for blood pressure measurement in the second trimester were 0.68 (95% confidence interval 0.64 to 0.72) for systolic blood pressure, 0.66 (0.59 to 0.72) for diastolic blood pressure, and 0.76 (0.70 to 0.82) for mean arterial pressure. Findings for the first trimester showed a similar pattern. Second trimester mean arterial pressure of 90 mm Hg or more showed a positive likelihood ratio of 3.5 (95% confidence interval 2.0 to 5.0) and a negative likelihood ratio of 0.46 (0.16 to 0.75). In women deemed to be at high risk, a diastolic blood pressure of 75 mm Hg or more at 13 to 20 weeks' gestation best predicted pre-eclampsia: positive likelihood ratio 2.8 (1.8 to 3.6), negative likelihood ratio 0.39 (0.18 to 0.71). Additional subgroup analyses did not show improved predictive accuracy. CONCLUSION: When blood pressure is measured in the first or second trimester of pregnancy, the mean arterial pressure is a better predictor for pre-eclampsia than systolic blood pressure, diastolic blood pressure, or an increase of blood pressure.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.39540.522049.be

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 241

Metadata

Authors
Cnossen, J. S., Vollebregt, K. C., Vrieze, N. D., Riet, G. T., Mol, B. W. J., Franx, A., Khan, K. S., & Post, J. A. M. V. D.
Venue
BMJ
Publisher
BMJ
Published
2008-05-14
Volume
336
Issue
7653
Pages
1117-1120
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2014942040
Cited by
241
References
5
FWCI
1.74
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of mean arterial pressure and blood pressure measurements in predicting pre-eclampsia: systematic review and meta-analysis. https://app.cochat.ai/papers/10.1136/bmj.39540.522049.be
The paper
Cnossen, J. S., Vollebregt, K. C., Vrieze, N. D., Riet, G. T., Mol, B. W. J., Franx, A., Khan, K. S., & Post, J. A. M. V. D. (2008). Accuracy of mean arterial pressure and blood pressure measurements in predicting pre-eclampsia: systematic review and meta-analysis. BMJ. https://doi.org/10.1136/bmj.39540.522049.be

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.