Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 236

The DOI matches its Crossref record.

Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trial

Open access
Hostler, D., Everson-Stewart, S., Rea, T. D., Stiell, I. G., Callaway, C. W., Kudenchuk, P. J., Sears, G. K., Emerson, S. S., Nichol, G., and the Resuscitation Outcomes Consortium Investigators · 2011 · BMJ

Abstract

OBJECTIVE: To investigate whether real-time audio and visual feedback during cardiopulmonary resuscitation outside hospital increases the proportion of subjects who achieved prehospital return of spontaneous circulation. DESIGN: A cluster-randomised trial. SUBJECTS: 1586 people having cardiac arrest outside hospital in whom resuscitation was attempted by emergency medical services (771 procedures without feedback, 815 with feedback). SETTING: Emergency medical services from three sites within the Resuscitation Outcomes Consortium in the United States and Canada. INTERVENTION: Real-time audio and visual feedback on cardiopulmonary resuscitation (CPR) provided by the monitor-defibrillator. MAIN OUTCOME MEASURE: Prehospital return of spontaneous circulation after CPR. RESULTS: Baseline patient and emergency medical service characteristics did not differ between groups. Emergency medical services muted the audible feedback in 14% of cases during the period with feedback. Compared with CPR clusters lacking feedback, clusters assigned to feedback were associated with increased proportion of time in which chest compressions were provided (64% v 66%, cluster-adjusted difference 1.9 (95% CI 0.4 to 3.4)), increased compression depth (38 v 40 mm, adjusted difference 1.6 (0.5 to 2.7)), and decreased proportion of compressions with incomplete release (15% v 10%, adjusted difference -3.4 (-5.2 to -1.5)). However, frequency of prehospital return of spontaneous circulation did not differ according to feedback status (45% v 44%, adjusted difference 0.1% (-4.4% to 4.6%)), nor did the presence of a pulse at hospital arrival (32% v 32%, adjusted difference -0.8 (-4.9 to 3.4)), survival to discharge (12% v 11%, adjusted difference -1.5 (-3.9 to 0.9)), or awake at hospital discharge (10% v 10%, adjusted difference -0.2 (-2.5 to 2.1)). CONCLUSIONS: Real-time visual and audible feedback during CPR altered performance to more closely conform with guidelines. However, these changes in CPR performance were not associated with improvements in return of spontaneous circulation or other clinical outcomes. Trial Registration Clinical Trials NCT00539539.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.d512

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 236

Metadata

Authors
Hostler, D., Everson-Stewart, S., Rea, T. D., Stiell, I. G., Callaway, C. W., Kudenchuk, P. J., Sears, G. K., Emerson, S. S., Nichol, G., & and the Resuscitation Outcomes Consortium Investigators
Venue
BMJ
Publisher
BMJ
Published
2011-02-04
Volume
342
Issue
feb04 1
Pages
d512-d512
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2092019678
Cited by
236
References
0
FWCI
23.05
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trial. https://app.cochat.ai/papers/10.1136/bmj.d512
The paper
Hostler, D., Everson-Stewart, S., Rea, T. D., Stiell, I. G., Callaway, C. W., Kudenchuk, P. J., Sears, G. K., Emerson, S. S., Nichol, G., & and the Resuscitation Outcomes Consortium Investigators. (2011). Effect of real-time feedback during cardiopulmonary resuscitation outside hospital: prospective, cluster-randomised trial. BMJ. https://doi.org/10.1136/bmj.d512

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.