Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To compare the clinical effectiveness of Kirschner wire fixation with locking plate fixation for patients with a dorsally displaced fracture of the distal radius. DESIGN: A multicentre two arm parallel group assessor blind randomised controlled trial with 1:1 treatment allocation. SETTING: 18 trauma centres in the United Kingdom. PARTICIPANTS: 461 adults with a dorsally displaced fracture of the distal radius within 3 cm of the radiocarpal joint that required surgical fixation. Patients were excluded if the surgeon thought that the surface of the wrist joint was so badly displaced it required open reduction. INTERVENTIONS: Kirschner wire fixation: wires are passed through the skin over the dorsal aspect of the distal radius and into the bone to hold the fracture in the correct anatomical position. Locking plate fixation: a locking plate is applied through an incision over the volar (palm) aspect of the wrist and secured to the bone with fixed angle locking screws. PRIMARY OUTCOME MEASURE: validated patient rated wrist evaluation (PRWE). This rates wrist function in two (equally weighted) sections concerning the patient's experience of pain and disability to give a score out of 100. SECONDARY OUTCOMES: disabilities of arm, shoulder, and hand (DASH) score, the EuroQol (EQ-5D), and complications related to the surgery. RESULTS: The baseline characteristics of the two groups were well balanced, and over 90% of patients completed follow-up. The wrist function of both groups of patients improved by 12 months. There was no clinically relevant difference in the patient rated wrist score at three, six, or 12 months (difference in favour of the plate group was -1.3, 95% confidence interval -4.5 to 1.8; P=0.40). Nor was there a clinically relevant difference in health related quality of life or the number of complications in each group. CONCLUSIONS: Contrary to the existing literature, and against the rapidly increasing use of locking plate fixation, this trial found no difference in functional outcome in patients with dorsally displaced fractures of the distal radius treated with Kirschner wires or volar locking plates. Kirschner wire fixation, however, is cheaper and quicker to perform. TRIAL REGISTRATION: Current Controlled Trials ISCRTN 31379280. UKCRN 8956.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple Imputation for Nonresponse in Surveys
Rubin, D. B. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316696 · Cited by 20,701
Multiple imputation using chained equations: Issues and guidance for practice
White, I. R., Royston, P., & Wood, A. M. (2011) · Statistics in Medicine · doi:10.1002/sim.4067 · Cited by 9,792
EuroQol: the current state of play
Brooks, R. (1996) · Health Policy · doi:10.1016/0168-8510(96)00822-6 · Cited by 5,815
Hudak, P. L., Amadio, P. C., Bombardier, C., Beaton, D., Cole, D., Davis, A., Hawker, G., Katz, J. N., Makela, M., Marx, R. G., et al. (1996) · American Journal of Industrial Medicine · doi:10.1002/(sici)1097-0274(199606)29:6<602::aid-ajim4>3.0.co;2-l · Cited by 5,025
Explanatory and pragmatic attitudes in therapeutical trials
Schwartz, D., & Lellouch, J. (1967) · Journal of Chronic Diseases · doi:10.1016/0021-9681(67)90041-0 · Cited by 1,185
Cited by
Boutron, I., Altman, D. G., Moher, D., Schulz, K. F., Ravaud, P., & for the CONSORT NPT Group* (2017) · Annals of Internal Medicine · doi:10.7326/m17-0046 · Cited by 1,538
Quotation errors related to the Distal Radius Acute Fracture Fixation Trial paper
Cay, P., Leung, B., Curlewis, K., Stone, A., Roper, T., & Ricketts, D. (2021) · Journal of Hand Surgery (European Volume) · doi:10.1177/17531934211002985 · Cited by 9
Metadata
- Authors
- Costa, M. L., Achten, J., Parsons, N. R., Rangan, A., Griffin, D., Tubeuf, S., Lamb, S. E., & on behalf of the DRAFFT Study Group
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2014-08-05
- Volume
- 349
- Issue
- aug05 2
- Pages
- g4807-g4807
- ISSN
- 1756-1833 (ISSN-L)
- OpenAlex
- W2044229831
- Cited by
- 211
- References
- 5
- FWCI
- 18.52
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial. https://app.cochat.ai/papers/10.1136/bmj.g4807
- The paper
- Costa, M. L., Achten, J., Parsons, N. R., Rangan, A., Griffin, D., Tubeuf, S., Lamb, S. E., & on behalf of the DRAFFT Study Group. (2014). Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial. BMJ. https://doi.org/10.1136/bmj.g4807
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.