What is publication bias in a meta-analysis?
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Researchers undertook a meta-analysis of the effectiveness of non-benzodiazepine hypnotics, including eszopiclone, zaleplon, and zolpidem. Randomised controlled trials were included if they were double blind, placebo controlled, and had parallel treatment groups. Participants were adults with primary insomnia (transient or chronic). The main outcomes were polysomnographic and subjective measurements of sleep latency.1 Thirteen trials were eligible for inclusion. When the results of the trials were combined, non-benzodiazepine hypnotics showed a significant improvement (reduction) in the main outcome of polysomnographic sleep latency compared with placebo (weighted mean raw difference −22.0 minutes, 95% confidence interval −33.0 to −11.0). Non-benzodiazepine hypnotics showed a small improvement in subjective sleep latency although the change was not significant (−6.9 minutes, −26.0 to 12.4). Improvements in sleep latency did not vary between individual hypnotics. The researchers also reported that Egger’s test showed no evidence that the results were significantly affected by publication bias. Which of the following, if any, would have resulted in publication bias?
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huedo-Medina, T. B., Kirsch, I., Middlemass, J., Klonizakis, M., & Siriwardena, A. N. (2012) · BMJ · doi:10.1136/bmj.e8343 · Cited by 313
Cited by
How to read a funnel plot in a meta-analysis
Sedgwick, P., & Marston, L. (2015) · BMJ · doi:10.1136/bmj.h4718 · Cited by 318
Self-citationXiao, J., Lim, L. K. E., Ng, C. H., Tan, D. J. H., Lim, W. H., Ho, C. S. H., Tan, E. X. X., Sanyal, A. J., & Muthiah, M. D. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.691696 · Cited by 94
“Publication bias was not assessed with the lack of a suitable tool in single-arm meta-analysis to assess publication bias and small quantity of included studies (32, 33).”
MethodKaripidis, K., Baaken, D., Loney, T., Blettner, M., Brzozek, C., Elwood, M., Narh, C., Orsini, N., Röösli, M., Paulo, M. S., et al. (2024) · Environment International · doi:10.1016/j.envint.2024.108983 · Cited by 58
Kohanmoo, A., Faghih, S., & Akhlaghi, M. (2020) · Physiology & Behavior · doi:10.1016/j.physbeh.2020.113123 · Cited by 56
Lagorio, S., Blettner, M., Baaken, D., Feychting, M., Karipidis, K., Loney, T., Orsini, N., Röösli, M., Paulo, M. S., & Elwood, M. (2021) · Environment International · doi:10.1016/j.envint.2021.106828 · Cited by 36
Metadata
- Authors
- Sedgwick, P.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2015-08-14
- Volume
- 351
- Pages
- h4419
- ISSN
- 1756-1833 (ISSN-L)
- OpenAlex
- W1889791828
- Cited by
- 101
- References
- 1
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: What is publication bias in a meta-analysis? https://app.cochat.ai/papers/10.1136/bmj.h4419
- The paper
- Sedgwick, P. (2015). What is publication bias in a meta-analysis? BMJ. https://doi.org/10.1136/bmj.h4419
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.