RoB 2: a revised tool for assessing risk of bias in randomised trials
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index; 15 of the 23 sources its claims cite were checked for support.
Abstract
Assessment of risk of bias is regarded as an essential component of a systematic review on the effects of an intervention. The most commonly used tool for randomised trials is the Cochrane risk-of-bias tool. We updated the tool to respond to developments in understanding how bias arises in randomised trials, and to address user feedback on and limitations of the original tool.
Overview
CoChat Summary
TL;DR
RoB 2 is a revised Cochrane risk-of-bias tool for randomised trials that assesses a single effect estimate in five bias domains using signalling questions and algorithm-supported judgments of low risk, some concerns, or high risk. It was developed through literature review, consultation, and piloting to address limitations of the 2008 tool, including unclear judgments and handling of unblinded trials and missing data.
Key findings
- RoB 2 structures assessment into five mandatory domains: bias arising from the randomisation process; bias due to deviations from intended interventions; bias due to missing outcome data; bias in measurement of the outcome; and bias in selection of the reported result. Each domain includes signalling questions, a domain-level risk-of-bias judgment, free-text justification, and optional prediction of bias direction.
- Judgments are “low risk of bias,” “some concerns,” or “high risk of bias.” The overall judgment generally corresponds to the worst risk of bias in any domain, but a study with “some concerns” in multiple domains might be judged as high risk overall. Algorithms map signalling-question responses to proposed domain judgments, and review authors can override them with reasons.
- Major changes from the original tool include removing the “unclear” judgment option, distinguishing the effect of assignment to intervention from the effect of adhering to intervention, recognising that open/unblinded trials can be at low risk of bias if there were no deviations from intended intervention arising because of trial context, and moving selective non-reporting of results to review-level assessment rather than the selection-of-reported-result domain.
- Development involved preliminary reviews, meetings with 24 contributors in August 2015 and April 2016, piloting in February 2016 with 17 participants present and 10 contributing remotely, and another pilot by 10 systematic review authors in mid-2016; a complete draft was posted in October 2016. The original Cochrane RoB tool had over 40 000 citations in Google Scholar.
Methods
- Methodological tool development following principles used for the original RoB tool and ROBINS-I; a core group coordinated development, with preliminary work including a review of how the original tool was used, a systematic review and meta-analysis of meta-epidemiological studies, a cross-sectional study of selective outcome reporting assessment in Cochrane reviews, and a review of theoretical/conceptual literature on bias.
- Working groups developed signalling questions and guidance; the core team assembled and edited materials, and drafts were piloted by experienced and novice systematic reviewers. Further modifications were made based on feedback from training events and webinars between 2016 and 2019.
- No primary empirical analysis of RoB 2 performance is reported; the paper describes the framework, domains, signalling questions, algorithms, and overall judgment mapping.
Limitations
- The paper does not report a formal limitations section. It states that empirical studies of the original tool found only moderate reliability of risk-of-bias judgments, and that appropriate methods for estimating per-protocol effects depend on strong assumptions and have relatively rare published applications.
- Evident from the text: this paper does not report reliability, validity, or impact data for RoB 2 itself; expected increases in low-risk judgments are stated as expectations rather than demonstrated outcomes.
- Evident from the text: algorithms can be overridden by review authors, and the tool requires judgment and access to trial protocols or other sources; the paper notes that review authors should contact trial authors to obtain omitted information “so far as this is feasible.”
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
12 Valid · 0 Not valid · 5 Not checked · 44 Own results and interpretations
Every source the paper cites for this claim was checked and supports it.
In the paper
“A review of comments and user practice found that both Cochrane and nonCochrane systematic reviews often implemented the RoB tool in non-standard ways. 6”
What the sources say
- Supportedcites [6] matched to “Evaluation of the Cochrane tool for assessing risk of bias in randomized clinical trials: overview of published comments and analysis of user practice in Cochrane and non-Cochrane reviews” (2016) source
The Discussion’s “Mechanisms and implications” section says the tool is often used in ways not recommended and that both Cochrane and non-Cochrane reviews implemented non-standard domains. This directly supports the claim; no page number is provided in our copy. (LLM, conf=0.94)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“We did not include domains for features that would be expected to operate indirectly, through the included bias domains. 14 15”
What the sources say
- Partly supportedcites [14] 14 Lundh A, Lexchin J, Mintzes B, Schroll JB, Bero L. Industry sponsorship and research outcome. Cochrane Database Syst Rev 2017;2:MR000033. sourceExperimental — accuracy not yet measured
In the Authors’ Conclusions (page unavailable), the review says the Cochrane Handbook does not recommend a separate industry-sponsorship domain because it assumes sponsorship’s influence is mediated through existing bias domains. But the review challenges that assumption and recommends a separate domain for industry bias, so it does not endorse the cited sentence’s general rationale for omitting domains. (LLM, conf=0.82)
- Partly supportedcites [15] 15 Bafeta A, Dechartres A, Trinquart L, Yavchitz A, Boutron I, Ravaud P. Impact of single centre status on estimates of intervention effects in trials with continuous outcomes: meta-epidemiological study. BMJ 2012;344:e813. doi:10.1136/bmj.e813 sourceExperimental — accuracy not yet measured
The Possible mechanisms section reports that single-centre status was associated with some assessed risk-of-bias domains, which supports a possible link between a trial feature and those domains. It also discusses other possible mechanisms. The paper does not say that such features are expected to operate indirectly through the included domains or recommend omitting separate domains for them. (LLM, conf=0.76)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Data from a randomised trial can be used to derive an unbiased estimate of the effect of adhering to intervention. 19 20”
What the sources say
- Supportedcites [19] 19 Murray EJ, Hernán MA. Adherence adjustment in the Coronary Drug Project: A call for better per-protocol effect estimates in randomized trials. Clin Trials 2016;13:372-8. doi:10.1177/1740774516634335 source
The Conclusions state that per-protocol effects—the effects under adherence to the trial protocol—can be validly estimated from clinical trials when sufficient data are available and appropriate adjustment methods are used. The claim says such an estimate can be derived, though it leaves those conditions unstated. No page number is provided in our copy. (LLM, conf=0.90)
- Partly supportedcites [20] 20 Lodi S, Sharma S, Lundgren JD, et al, INSIGHT Strategic Timing of AntiRetroviral Treatment (START) study group. The per-protocol effect of immediate versus deferred antiretroviral therapy initiation. AIDS 2016;30:2659-63. doi:10.1097/QAD.0000000000001243 sourceExperimental — accuracy not yet measured
The Methods describe using randomized START trial data to estimate the effect had all participants adhered to their assigned strategy. But the Discussion says the adjusted estimate depends on accurately measuring prognostic factors and correctly specifying the models—conditions the authors say cannot be guaranteed. The claim’s unqualified assertion of an unbiased estimate overstates the source. (LLM, conf=0.87)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Assessments for the domain 'bias due to deviations from intended interventions' differ according to whether review authors are interested in quantifying the effect of assignment to the interventions at baseline regardless of whether the interventions are received during follow-up (intention-to-treat effect), or the effect of adhering to intervention as specified in the trial”
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
In the paper
“Empirical studies have found only moderate reliability of risk-of-bias judgments. 8”
What the sources say
- Not checked — no full text of the sourcecites [8] 8 Hartling L, Hamm MP, Milne A, et al. Testing the risk of bias tool showed low reliability between individual reviewers and across consensus assessments of reviewer pairs. J Clin Epidemiol 2013;66:973-81. doi:10.1016/j.jclinepi.2012.07.005 source
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
5 more claims
Create a free account to see all 61 claims and to verify the 1 reference still open.
- Probably not a substantial claim. 44
- It may state two separate claims as one. 21
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“An in-depth evaluation of study quality was conducted, in addition to the standard Cochrane RoB 2 and CONSORT checklist [7].”
From Ivermectin for COVID-19: Addressing Potential Bias and Medical Fraud (2022) · cites this paper as [7]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The methodological reporting quality of included studies was assessed using the Cochrane Risk of Bias (RoB 2) tool for crossover trials [23].”
From The effect of caffeine on subsequent sleep: A systematic review and meta-analysis (2023) · cites this paper as [23]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“the assessment of the only RCT, Dessy (2010) [3], with Cochrane’s RoB 2.0 tool raised some concerns regarding risk of bias, although it did not reach a high level of risk of bias [17].”
From Reconstructive Procedures of the Auricular Concha after Cutaneous Oncologic Surgery: A Systematic Review (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In addition, it was unclear whether the analysis plan yielding the study’s results was fully established prior to the unblinded results becoming available [3,17].”
From Reconstructive Procedures of the Auricular Concha after Cutaneous Oncologic Surgery: A Systematic Review (2023) · cites this paper as [17]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“All other aspects of the randomized control trial had low risk of bias. Since there were no missing data, the outcome (aesthetic results) was measured adequately, and there were no deviations from the assigned interventions [3,17].”
From Reconstructive Procedures of the Auricular Concha after Cutaneous Oncologic Surgery: A Systematic Review (2023) · cites this paper as [17]
Experimental — accuracy not yet measured
156 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
The Cochrane Collaboration's tool for assessing risk of bias in randomised trials
Higgins, J. P. T., Altman, D. G., Gotzsche, P. C., Juni, P., Moher, D., Oxman, A. D., Savovic, J., Schulz, K. F., Weeks, L., Sterne, J. A. C., et al. (2011) · BMJ · doi:10.1136/bmj.d5928 · Cited by 33,817
Self-citationGRADE: an emerging consensus on rating quality of evidence and strength of recommendations
Guyatt, G. H., Oxman, A. D., Vist, G. E., Kunz, R., Falck-Ytter, Y., Alonso-Coello, P., & Schünemann, H. J. (2008) · BMJ · doi:10.1136/bmj.39489.470347.ad · Cited by 23,305
ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions
Sterne, J. A., Hernán, M. A., Reeves, B. C., Savović, J., Berkman, N. D., Viswanathan, M., Henry, D., Altman, D. G., Ansari, M. T., Boutron, I., et al. (2016) · BMJ · doi:10.1136/bmj.i4919 · Cited by 20,329
Self-citationQUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Self-citationGRADE guidelines: 1. Introduction—GRADE evidence profiles and summary of findings tables
Guyatt, G., Oxman, A. D., Akl, E. A., Kunz, R., Vist, G., Brozek, J., Norris, S., Falck-Ytter, Y., Glasziou, P., & deBeer, H. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.04.026 · Cited by 10,681
Industry sponsorship and research outcome
Lundh, A., Lexchin, J., Mintzes, B., Schroll, J. B., & Bero, L. (2017) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.mr000033.pub3 · Cited by 1,697
Post-randomisation exclusions: the intention to treat principle and excluding patients from analysis
Fergusson, D., Aaron, S. D., Guyatt, G., & Hébert, P. (2002) · BMJ · doi:10.1136/bmj.325.7365.652 · Cited by 708 · cited 1×
“The effect of assignment to intervention should be estimated by an intention-to-treat (ITT) analysis that includes all randomised participants.(17) However, estimates of per-protocol effects commonly used in reports of randomised trials are problematic and may be seriously biased.”
BackgroundPer-Protocol Analyses of Pragmatic Trials
Hernán, M. A., & Robins, J. M. (2017) · New England Journal of Medicine · doi:10.1056/nejmsm1605385 · Cited by 660 · cited 4×
“For trials comparing interventions that are sustained over time, appropriate methods also require measurement of and adjustment for both the pre- and post-randomisation prognostic factors that predict deviations from intervention.(11) For these reasons, most systematic reviews are likely to address the effect of assig…”
BackgroundMethodInfluentialSelf-citationQUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Self-citationBeyond the intention-to-treat in comparative effectiveness research
Hernán, M. A., & Hernández-Díaz, S. (2012) · Clinical Trials · doi:10.1177/1740774511420743 · Cited by 528
Self-citation
Cited by
Items 30,801–30,900 of 32,539
Amouri, M., Deeb, S., Deeb, N., et al. (2026) · Journal of Perinatology · doi:10.1038/s41372-026-02842-3
Basavanna, G. K., Garcia, B. G., de Azevedo, R. F., Lesinszki, L. S., Hakkeem, B., & Humbre, S. (2026) · Critical Care Science · doi:10.62675/2965-2774.20260413
“(16) In contrast, a study in the ED observed 31.1% of adverse events associated with ramping, and 24.5% with sniffing.”
InfluentialShan, Z., Yang, W., & Wang, P. (2026) · Frontiers in Psychology · doi:10.3389/fpsyg.2026.1888190 · Cited by 5
“The main synthesis used a Bayesian multilevel random-effects meta-analysis implemented in R 4.5.1 with the brms package (Sterne et al., 2019).”
InfluentialBhatti, M. I., Qadri, M., Asif, A., et al. (2026) · Therapeutic Advances in Ophthalmology · doi:10.1177/25158414261472730
Liang, Y., Deng, X., 陈美霞, et al. (2026) · BMC Ophthalmology · doi:10.1186/s12886-026-05146-4
“Risk of bias was assessed at the outcome level using the Cochrane Risk of Bias 2 (RoB 2) tool [36].”
Xu, Y., Shen, H., & Yang, Y. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2026.1857245
“Two reviewers (YX and HS) independently used the ROB2 (19) to assess the risk of bias.”
Lumowa, F. S. R., Kurniawati, E. M., & Hardianto, G. (2026) · International Urogynecology Journal · doi:10.1007/s00192-026-06818-x
Soeroto, A. A., Lionardi, S. K., & Wahyudi, I. (2026) · Research Square · doi:10.21203/rs.3.rs-10457783/v1
Estrada‐Plana, V., Vita‐Barrull, N., March‐Llanes, J., Badia-Bafalluy, A., Ayesa‐Arriola, R., & Moya-Higueras, J. (2026) · Applied Psychology Health and Well-Being · doi:10.1111/aphw.70194
“We used the RoB 2.0 Cochrane's tool (Sterne et al., 2019) when the studies were individually RCTs.”
InfluentialFunctional Outcomes of Dorsal Preservation Rhinoplasty: A Systematic Review and Meta-analysis
Chan, C., North, A. S., Mansour, H. R. K., Saban, Y., & Joshi, A. K. (2026) · Facial Plastic Surgery · doi:10.1055/a-2927-6789
Hickey, C., Sidovar, M. F., García, A., Kramer, K., Chang, J.-Y. A., Kupas, K., Telukuntla, V., Horgan, J., Jameel, H., Westley, T., et al. (2026) · Journal of Comparative Effectiveness Research · doi:10.57264/cer-2026-0045
“…included in NMAs was assessed using the Cochrane Risk of Bias tool version 2 (RoB 2), which evaluates potential bias across domains such as randomization process, deviations from intended interventions, missing outcome data, measurement of the outcome and selection of the reported results [29] .”
Development of a tool to assess the risk of bias in statistical simulation studies: study protocol
Arnup, S. J., Turner, S., Page, M. J., Korevaar, E., McDonald, S. J., Higgins, J. P. T., & McKenzie, J. E. (2026) · F1000Research · doi:10.12688/f1000research.184100.1
Self-citationZhang, Z., He, Z., & Long, K. (2026) · Frontiers in Neurology · doi:10.3389/fneur.2026.1902987
“Meanwhile, many studies did not adopt the RoB 2 and GRADE frameworks for systematic methodological appraisal (19, 20).”
Alia, L. A. A., Alkhawaldeh, I. M., Serag, I., et al. (2026) · Neurosurgical Review · doi:10.1007/s10143-026-04413-8
“For randomized controlled trials, ROB 2 tool was applied [18].”
AlMahmeed, A. S. (2026) · Trends in Computer Science and Information Technology · doi:10.17352/tcsit.000114
Felsypremila, G., Kumaraguru, M., Geminiganesan, S., et al. (2026) · Future Microbiology · doi:10.1080/17460913.2026.2707866
Santos, E. H., Paixão, L., Munaro, G. R., Surmani, N. N., Grigonis, M. P., Obara, K., Silva, M. F., & Cardoso, J. R. (2026) · Archives of Rehabilitation Research and Clinical Translation · doi:10.1016/j.arrct.2026.100678
Tudella, G. C. N., Pereira, M. A. O. M., Klostermann, A. U., Gonzalez, J. V. P., Gonçalves, O. R., Donato, K. O., Nantes, L. A. D. O., da Silva, A. M. P., Forte, A. R. C. C., Patrocínio, M. L. V., et al. (2026) · Journal of Clinical Psychopharmacology · doi:10.1097/jcp.0000000000002231
Buntain, H. H., Thompson, M., Perry, C., Hunter, O., Zahir, S. F., & Basu, B. B. (2026) · ANZ Journal of Surgery · doi:10.1111/ans.70861
Jaramillo, R. A. G., Avendaño, L. I., González, A. M. B., Suárez, B. D., Becerra, J. L. R., García, E. J., & Quintero, C. J. M. (2026) · Hernia · doi:10.1007/s10029-026-03807-3 · Cited by 1
“Risk of bias in RCTs was assessed using the revised Cochrane ROB-2 tool [18], which evaluates five domains: D1 randomization process; D2 deviations from intended interventions; D3 missing outcome data; D4 measurement of the outcome; D5 selection of the reported result.”
Eost‐Telling, C., McGarrigle, L., Shi, C., Money, A., Yang, Y., Green, K. L., Ahmed, S., Christie, R., Aminu, A. Q., Delbaere, K., et al. (2026) · JMIR Aging · doi:10.2196/89807
Milasi, C., Maggio, M. G., Perrotti, G., Barbuto, P., Barberio, M., Albertini, A., Tallarico, N., Rocca, F., Contrada, M., Gallivanone, F., et al. (2026) · Bioengineering · doi:10.3390/bioengineering13080883
“The methodological quality of the included randomized controlled trials (RCTs) was assessed using the revised Cochrane Risk of Bias tool for randomized trials (RoB 2) [27].”
Alraddadi, S. E., Almeghthawi, A. H., Alahmadi, H. N., et al. (2026) · Journal of Robotic Surgery · doi:10.1007/s11701-026-03728-4
Naye, F., Ouellet, S., Yousefi, F., Cachinho, C., Bergeron, F., Bhattacharyya, O. K., Stamenova, V., & Sasseville, M. (2026) · Journal of Medical Internet Research · doi:10.2196/96882 · Cited by 2
Salma, Z. N., Anwar, D. F. F., Hibatulloh, M. F., et al. (2026) · Tzu Chi Medical Journal · doi:10.4103/tcmj.tcmj-d-25-00170
Alrumaih, F. A., Alharbi, A., Albattah, F. M., et al. (2026) · Cureus · doi:10.7759/cureus.113715
“Randomized controlled trials were evaluated using the Cochrane Risk of Bias 2.0 (RoB 2.0) tool (Cochrane, London, UK) [6].”
InfluentialKang, Y., Habibula, S., Heffernan, C., Farmer, C., Meléndez‐Torres, G. J., Nurse, J., & Fellmeth, G. L. (2026) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd016376
The Impact of Video Game Experience on Surgical Performance: A Systematic Review
Freeman, J., Zak, I., McConnell, T., Pitaluga, R., Williams, A., Xu, J., & Frain, J. (2026) · Journal of surgical education · doi:10.1016/j.jsurg.2026.104076
Chene, G., Timoh, K. N., Agostini, A., Bendifallah, S., Solignac, C., Darné, B. M., Languille, S., Miquel, L., & Carbonnel, M. (2026) · Journal of Minimally Invasive Gynecology · doi:10.1016/j.jmig.2026.07.036
Miranda, C., Castilho, P., Guiomar, R. N. R. M., The VR-ACT Project Team, Carvalho, S. A., Menezes, P. J., Duarte, C., Skvarc, D., Silva, A. R., Valentim, A., et al. (2026) · Journal of Health Psychology · doi:10.1177/13591053261470710
Yangyang, C., Chen, J., Xiao, X., Li, Y., Du, H., Min, W., & Zhang, X. (2026) · medRxiv · doi:10.64898/2026.07.29.26359223
Kolonics, M. V., Martyin, K., Galajda, N. Á., Meznerics, F. A., Abed, A., Fazekas, K. K., Krebs, M., Ungvári, Á., Czibulya, A., Kulyassa, P. M., et al. (2026) · Dermatologic Therapy · doi:10.1155/dth/8514168
Gadelmawla, A. F., El-Farargy, S. H., Alsubaiei, A. A., AlSejari, N., Artam, A. S., Elgendy, M. S., Hekal, M., Abdul‐Hafez, H. A., Elnady, M., Diaa, A., et al. (2026) · Cardiology in Review · doi:10.1097/crd.0000000000001414
Yang, F., Tao, S., Liu, X., & Zhang, Z. (2026) · International Journal of Nursing Practice · doi:10.1111/ijn.70176
Pramadika, T., Saputra, T., Mochamat, M., Caesarino, R. I., Wicaksono, S. A., Nurcahyo, W. I., & Ksatriaputra, A. (2026) · doi:10.2196/preprints.107439
Chang, C.-Y., Lin, Y., Chen, P.-Y., et al. (2026) · Life · doi:10.3390/life16081270
“…evidence, we appraised the risk of bias of the pivotal AC-specific RCTs using the domains of the revised Cochrane Risk of Bias tool (RoB 2) [19]; the resulting judgments, together with study design characteristics (single-versus multicenter; blinded versus open-label; a priori power…”
Chen, Y., Huamin, P., Tang, L., & Luo, M. (2026) · doi:10.2196/preprints.107842
Cuba-Gutierrez, L., Invernón-Monedero, M., Osuna, E., et al. (2026) · Forensic Science Medicine and Pathology · doi:10.1007/s12024-026-01309-3
Zhang, S., Ren, Y., Zhang, Q., & Fan, Y. (2026) · BMJ Open · doi:10.1136/bmjopen-2026-120579
Perez, M. C. P., Machado, G. D., Leister, H. W. D. A., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-10155665/v1
Naccarato, M., Ricci, E., Vincis, E., et al. (2026) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2026.108717
Patel, S., Nischal, S. A., Nallanukala, G. S., et al. (2026) · European Spine Journal · doi:10.1007/s00586-026-10214-w
Silvinato, A., Floriano, I., & Bernardo, W. M. (2026) · Revista da Associação Médica Brasileira · doi:10.1590/1806-9282.2026d726
“Two independent reviewers (AS, IF) assessed the risk of bias in the included studies using the Revised Cochrane Risk-of-Bias tool (RoB 2) 6 This instrument evaluates five specific domains: (1) bias arising from the randomization process; (2) bias due to deviations from intended interventions; (3)…”
Eluigwe, K. N., Okoye, N. A., Olatunji, O. L., & Oka, O. U. (2026) · Journal of Applied Gerontology · doi:10.1177/07334648261470134
Zou, S., Liu, R., Zhang, S., et al. (2026) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2026.108710
Li, H., Dong, S., & Cheng, Y. (2026) · Medicine · doi:10.1097/md.0000000000050074
“[32] Two authors (LHL, DSW) independently carried out the assessment, with discrepancies resolved by a third author (CYM).”
Adult tooth regeneration: can blood beat biomaterials?
Jonker, C. H. (2026) · Evidence-Based Dentistry · doi:10.1038/s41432-026-01239-7
Sewify, K., Elmessery, R., Alzuwayed, O., Gomaa, W., Alshaer, A., Almutairi, A., Abdelshafey, E. E., & Girardis, M. (2026) · Critical Care Explorations · doi:10.1097/cce.0000000000001451 · Cited by 3
Low, E., Flicker, L. A., Smith, L., & Iddagoda, M. T. (2026) · Perioperative Care and Operating Room Management · doi:10.1016/j.pcorm.2026.100714
Gundogan, N., Kaya, T. T., Halaç, E., Süt, E., & Çıray, R. O. (2026) · Human Psychopharmacology Clinical and Experimental · doi:10.1002/hup.70058
“Risk of bias was assessed using the RoB 2 tool for 10 RCTs and ROBINS‐”
InfluentialHeierli, G., Grass, F., Pereira, L. C., et al. (2026) · World Journal of Surgery · doi:10.1002/wjs.70490
“A systematic assessment of risk of bias was conducted by two authors (GH and MH), using the RoB 2 tool [29] for randomized studies and the ROBINS‐”
Cardoso, J. H. C. O., Collaço, B. G., MACRET, J. Z., et al. (2026) · Hernia · doi:10.1007/s10029-026-03744-1
Zailai, A. M., Noor, A., Alkhawari, D., Elsherbeny, S. H., Alsaffar, L., Alshaghdali, B. O., Alsakran, R., Al-Sultan, Y. A., Aldhumayri, N. F., Alqudaihi, W., et al. (2026) · Cureus · doi:10.7759/cureus.113767
“For RCTs, RoB 2 (The Cochrane Collaboration, London, UK) was utilized to evaluate the randomization process, deviations from intended interventions, missing outcome data, measurement of the outcome, and selection of the reported results [16].”
Abadi, A., Ghanem, U. I., Ghanem, H., et al. (2026) · Endocrinology Diabetes & Metabolism · doi:10.1002/edm2.70301
“The Cochrane Risk of Bias (ROB2) tool was used to assess study quality, with each domain scored as 1 (low), 2 (moderate), or 3 (high) risk [10].”
Boutros, M., Awad, G., Assi, A., et al. (2026) · European Journal of Orthopaedic Surgery & Traumatology · doi:10.1007/s00590-026-04871-2
“Methodological quality was independently assessed by two reviewers using the Risk of Bias in Non-randomized Studies of Interventions (ROBINS-I) tool [ 12] for non-randomized studies and the Cochrane Risk of Bias tool (RoB 2) [ 13] for randomized controlled trials.”
Dhale, A., & Dharaiya, D. K. (2026) · Psychiatric Quarterly · doi:10.1007/s11126-026-10303-5
Wang, Y., Zhang, H., Wang, J., Feng, W., Sun, Z., & Chen, Y. (2026) · International Journal of Nursing Practice · doi:10.1111/ijn.70177
Vitamin D Dosages and Extra-Skeletal Outcomes in Adults: A Systematic Review ProtocolPreprint
Dhorajiwala, S. S., Shankpal, P. D., Dhage, S., et al. (2026) · Research Square · doi:10.21203/rs.3.rs-10437208/v1
Alsayed, O., Jarai, M. Z., Khan, S., & Sandal, M. (2026) · Cureus · doi:10.7759/cureus.113777 · Cited by 1
“Risk of bias for RCTs was evaluated using the Cochrane Risk of Bias 2 (RoB 2) tool (five domains) [5].”
Kumar, J., Ganguly, S., Kaur, P., Raghav, A., Pai, K., Meena, J., Goyal, J. P., & Yadav, J. (2026) · The Indian Journal of Medical Research · doi:10.25259/ijmr_3200_2025
Khabaz, K., Alananzeh, R., Alkhani, L., et al. (2026) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-026-04563-8
Feng, J., Liang, S., Yang, L., et al. (2026) · BMC Surgery · doi:10.1186/s12893-026-04060-2
“The risk of bias of the included RCTs was assessed independently by two reviewers using the Cochrane Risk of Bias 2 (RoB 2) tool [10].”
Lv, R., Wang, X., Li, H., Yang, Z., Ye, L., & Zhou, M. (2026) · Frontiers in Endocrinology · doi:10.3389/fendo.2026.1926728 · Cited by 1
Mandal, S., Virdi, P., Singh, K., & Pathak, R. (2026) · The Indian Journal of Medical Research · doi:10.25259/ijmr_3058_2025
Menichelli, D., Malatesta, D., Pannunzio, A., Farcomeni, A., Violi, F., Pignatelli, P., & Pastori, D. (2026) · Internal and Emergency Medicine · doi:10.1007/s11739-026-04480-1 · Cited by 1
“Two authors (D.M. and A. P.) independently assessed RoB using the Cochrane ROB2 tool [17] for RCTs, which evaluates the following domains: bias arising from the randomization process, bias due to deviations from intended interventions, bias due to missing outcome data, bias in measurement of the…”
Chen, K., Liu, J., Zhang, J., & Liu, S. (2026) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2026.1889186
Gordilho, R. M. V., Barretto, N. J. C. L., Silvão, R. B. F., Pazos, F. P. G., Queiroz, P. R., Figueiredo, M. O., Souza, R. A. F., Oliva, J. P. G. D. C., Góes, L. G. F. S., Oliveira, R. C. R. C., et al. (2026) · BJUI Compass · doi:10.1002/bco2.70257
“17 Two reviewers performed the assessments independently, with disagreements resolved by a third reviewer.”
Yoshida, K., Nakazawa, Y., & Takahashi, S. (2026) · Nutrients · doi:10.3390/nu18152505
“In addition, we assessed the risk of bias using the Cochrane Risk of Bias version 2.0 (RoB2 tool [29]) as a post hoc assessment.”
InfluentialWong, S., Baek, J., Zhang, M. C., Fabiano, N., Zhou, C., Lee, E. K., Solmi, M., Husain, M. I., & Mak, M. S. B. (2026) · Psychiatry International · doi:10.3390/psychiatryint7040170
“Risk of bias was assessed independently by two investigators (JB, MZ) using the Cochrane Risk of Bias Tool for Randomized Controlled Trials 2 (RoB-2) [28].”
Cai, S., Shi, S., Liu, H.-J., et al. (2026) · Journal of Nephrology · doi:10.1093/joneph/aajag212
Could Dupilumab Improve Sleep Quality in CRSwNP Patients: Myth or Reality? A Systematic Review
Moffa, A., Corso, E. D., Nardelli, D., et al. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15156010
Wang, H.-Q., Jiang, Y., Zhu, L., Fan, M., Zhao, Y.-Q., & Wang, D.-M. (2026) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2026.1902938
Costa, M. J. F., Lima, N. B., Santos, R. F., Rolim, H. J. D. S., de Oliveira, F. J. D., de Barros, A. V. V. M., Lopes, D. S., & Sette-de-Souza, P. H. (2026) · Odontology · doi:10.1007/s10266-026-01516-y
Jung, J. H. (2026) · Healthcare · doi:10.3390/healthcare14152355
“Each domain was rated as “low risk”, “some concerns”, or “high risk” based on the signaling questions, and an overall risk-of-bias judgment was then determined [37].”
Eroğlu, M. N., Pancar, S., Torres, O. L., & Fernández-Elías, V. E. (2026) · Nutrients · doi:10.3390/nu18152513 · Cited by 1
“In addition to the PEDro assessment, the risk of bias in the included randomized trials was evaluated using the Cochrane Risk of Bias 2 (RoB 2) tool [31].”
Singh, S., Ghosh, S., Arya, V. P., Chakraborty, D., & Balkrishna, A. (2026) · BMC Agriculture · doi:10.1186/s44399-026-00047-9
“Based on their overall score, studies were rated as Good (7–9 stars), Fair (4–6 stars), or Poor (0–3 stars) [37].”
Breakspear, R.-M., Bindal, Z., Chen, F. S., & Schmader, T. (2026) · American Journal of Men s Health · doi:10.1177/15579883261473332
“Risk of bias was assessed using the revised Cochrane Risk of Bias tool for randomized trials (RoB 2; Sterne et al., 2019).”
Burhan, M., Siddiqui, M., Khalid, M., et al. (2026) · Cardiology in Review · doi:10.1097/crd.0000000000001397
Tsai, W.-W., Lu, K.-H., Lin, K.-H., Wu, J., Lai, C.-C., Hung, K. C., Tsai, Y.-T., & Hsieh, M. (2026) · Therapeutic Advances in Neurological Disorders · doi:10.1177/17562864261474987
Li, Y., Zhao, X., Zhang, W., Wu, H., Tian, Q., Ma, F. Y., He, D., & Cai, Y. (2026) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-026-01936-x
“In contrast, domains related to missing outcome data, measurement of outcomes, and selection of the reported results were more commonly judged as low risk or some concerns rather than high risk [24].”
InfluentialFeng, X., Kanukula, R., Evangelidis, N., Neal, B. C., Davidson, P. M., Koczwara, B., Lee, K. H., & Astell‐Burt, T. (2026) · medRxiv · doi:10.64898/2026.08.02.26359484
Pilot Study: Facial Trauma Reconstruction Outcomes: Systematic Review and Meta-analysis
Nadeem-Tariq, A., Guardia, J. L., Childers, E. J., et al. (2026) · Plastic & Reconstructive Surgery Global Open · doi:10.1097/gox.0000000000007939
Kalpakidis, D., Efthimiou, G., Skanavis, C., & Papadas, I. T. (2026) · Die Naturwissenschaften · doi:10.1007/s00114-026-02139-7
“…design-specific, domain-based approach informed by the principles of established instruments, namely the Cochrane RoB 2 tool for randomized trials (Sterne et al. 2019) and ROBINS-I for non-randomized studies of interventions (Sterne et al. 2016), supplemented by exposure-assessment criteria for…”
Platelet Transfusion in Dengue-Associated Thrombocytopenia: A Systematic Review and Meta-Analysis
Carretta, L. T. A., Cosmo, L. D., Faria, L. C., OLIVEIRA, N. B. D., Teixeira, P. R., Fernandes, J. V. A., Lopes, L. B., & Oliveira, F. R. (2026) · Revista da Sociedade Brasileira de Medicina Tropical · doi:10.1590/0037-8682-0181-2025
“The methodological quality of the included RCTs was assessed using the Cochrane Risk of Bias 2 (RoB 2) tool 9 , which evaluates five domains: randomization process, deviations from intended interventions, missing outcome data, measurement of outcomes, and selection of the reported result.”
Radiofrequency Neurolysis of the Posterior Nasal Nerve: A Systematic Review and Meta‐Analysis
Jamileh, E., Muhammad, F., Xamza, M., et al. (2026) · The Laryngoscope · doi:10.1002/lary.70763
Hamm‐Buiar, L., Gorski, D., Kagueiama, M. H., & Wiens, A. (2026) · British Journal of Clinical Pharmacology · doi:10.1002/bcp.70719 · Cited by 1
Fronk, K., Wysokiński, M., Podgórski, R., & Łuszczki, E. (2026) · Nutrients · doi:10.3390/nu18152483
“Randomized trials were assessed using an outcome-specific, structured domain-based approach informed by Cochrane RoB 2 [6], considering the randomization process, deviations from intended interventions, missing outcome data, outcome measurement, and selection of the reported result.”
Lefebvre, I., Dion, P., Boet, S., et al. (2026) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-026-03159-7
“19,20 Disagreements were resolved by consensus with the third reviewer.”
Lleó-Forcada, A., Comes‐Fayos, J., & Moya‐Albiol, L. (2026) · Community Mental Health Journal · doi:10.1007/s10597-026-01700-y
Episodic memory rehabilitation for HIV ‐associated neurocognitive disorders: A scoping review
Andersen, S., & Faure, S. (2026) · Journal of Neuropsychology · doi:10.1111/jnp.70069
Lastoria, D. A. A., Hunt, A., Ross, C., et al. (2026) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-026-06440-y
“In addition, the CLARITY tools for cohort and case-control studies were used [ 17 ], as well as the Cochrane collaboration tools for randomised controlled trials and non-randomised studies of intervention [ 18, 19 ].”
Song, X., Sun, L., Jin, J., Dai, M., & Qu, H. (2026) · Interactive Learning Environments · doi:10.1080/10494820.2026.2690472
Chen, J., Wu, Y., Xu, H., Ren, Y., Yang, R., Yao, S., Luo, W., Yi, J., He, X., & Zhang, L. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1792091
“…evaluated the methodological quality of each RCT using the Cochrane Risk of Bias 2 (RoB 2) tool, assessing fi ve domains: randomization process, deviations from intended interventions, missing outcome data, measurement of outcomes, and selection of reported results (Sterne et al., 2019).”
Zhou, S., Li, J., Weng, X., Zheng, H., Weng, X., Yin, M., Yuan, L., & Yang, Y. (2026) · JMIR Serious Games · doi:10.2196/93610
Tang, G., Cho, U., Zhang, J., & Chen, M. (2026) · Frontiers in Psychiatry · doi:10.3389/fpsyt.2026.1868153
“Reporting adheres to the PRISMA 2020 guidance (17); risk of bias was independently appraised in duplicate using RoB 2 (18); pooling employed the Hartung – Knapp – Sidik – Jonkman adjustment, which is more robust than the standard z-based con fi dence interval when the number of studies is small; and…”
Shaban, M., Mohammed, H. H., Osman, Y. M. M., & Shaban, M. M. (2026) · Journal of Advanced Nursing · doi:10.1111/jan.70706
Namozova, F., Mamede, I., Felippe, C. A., Rodrigues, E., & Stecca, C. (2026) · International Journal of Clinical Oncology · doi:10.1007/s10147-026-03144-6
“Owing to the limited number of included studies ( 10), funnel plot assessment and Egger’s regression test were not performed, in accordance with Cochrane recommendations [9].”
Vanegas, A. P. A., Díaz, D. C. C., Prada, J. D. S., Moreno, J. V. S., & Rodríguez, D. P. G. (2026) · Actas Urológicas Españolas (English Edition) · doi:10.1016/j.acuroe.2026.502060
A Systematic Review of Arnica montana in Postoperative Recovery Across Surgical Specialties
Stack, E. R., Spongberg, C. V., O'Neal, K., et al. (2026) · Cureus · doi:10.7759/cureus.113960
Lemborexant Versus Sedative-Hypnotics in the Treatment of Insomnia: A Systematic Narrative Review
Holloway, B., & Sandrini, J. (2026) · Sleep and Vigilance · doi:10.1007/s41782-026-00366-6
Metadata
- Authors
- Sterne, J. A. C., Savović, J., Page, M. J., Elbers, R. G., Blencowe, N. S., Boutron, I., Cates, C. J., Cheng, H.-Y., Corbett, M. S., Eldridge, S. M., Emberson, J. R., Hernán, M. A., Hopewell, S., Hróbjartsson, A., Junqueira, D. R., Jüni, P., Kirkham, J. J., Lasserson, T., Li, T., McAleenan, A., Reeves, B. C., Shepperd, S., Shrier, I., Stewart, L. A., Tilling, K., White, I. R., Whiting, P. F., & Higgins, J. P. T.
- Affiliations
- University of Bristol (GB)
- University Hospitals Bristol NHS Foundation Trust (GB)
- Monash University (AU)
- Inserm (FR)
- University of London (GB)
- University of York (GB)
- Queen Mary University of London (GB)
- University of Oxford (GB)
- University of Southern Denmark (DK)
- University of Alberta (CA)
- St. Michael's Hospital (CA)
- University of Manchester (GB)
- Cochrane (GB)
- Johns Hopkins University (US)
- Jewish General Hospital (CA)
- MRC Clinical Trials Unit at UCL (GB)
- Corresponding author
- Sterne, Jonathan A C
- ORCID
- Sterne, Jonathan A C
- Savović, Jelena
- Page, Matthew J
- Elbers, Roy G
- Blencowe, Natalie S
- Boutron, Isabelle
- Cates, Christopher J
- Cheng, Hung-Yuan
- Corbett, Mark S
- Eldridge, Sandra M
- Emberson, Jonathan R
- Hopewell, Sally
- Hróbjartsson, Asbjørn
- Junqueira, Daniela R
- Jüni, Peter
- Kirkham, Jamie J
- Lasserson, Toby
- Li, Tianjing
- McAleenan, Alexandra
- Reeves, Barnaby C
- Shepperd, Sasha
- Shrier, Ian
- Stewart, Lesley A
- Tilling, Kate
- White, Ian R
- Whiting, Penny F
- Higgins, Julian P T
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2019-08-28
- Volume
- 366
- Pages
- l4898
- ISSN
- 1756-1833 (ISSN-L)
- 0959-8138
- OpenAlex
- W2970684805
- Cited by
- 34,787
- References
- 22
- Citations by year
- 2026: 8601 · 2025: 7702 · 2024: 6341 · 2023: 4587 · 2022: 3752 · 2021: 2648 · 2020: 1045 · 2019: 69
- FWCI
- 594.37
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- www.bmj.com/company/legal-information/terms-conditions/legal-information/tdm-licencepolicy (tdm)
- Locations
- BMJ (publishedVersion)
- PubMed (publishedVersion)
- White Rose Research Online (University of Leeds, The University of Sheffield, University of York) (acceptedVersion)
- Oxford University Research Archive (ORA) (University of Oxford) (acceptedVersion)
- Bristol Research (University of Bristol) (acceptedVersion, other-oa)
- St George's Online Research Archive (St George's University of London) (acceptedVersion)
- LSHTM Research Online (London School of Hygiene and Tropical Medicine) (acceptedVersion)
- Research Explorer (The University of Manchester) (submittedVersion, other-oa)
- Monash University Research Portal (Monash University) (submittedVersion, other-oa)
- UCL Discovery (University College London) (submittedVersion)
- eScholarship@McGill (McGill) (submittedVersion, cc-by)
- HighWire Press Open Archive (submittedVersion)
- Queen Mary Research Online (Queen Mary University of London) (submittedVersion)
- Explore Bristol Research (submittedVersion, other-oa)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion, cc-by-nc)
- Funders
- Amgen
- Eli Lilly and Company
- CHDI Foundation
- Patient-Centered Outcomes Research Institute
- Wellcome Trust
- University Hospitals Bristol NHS Foundation Trust
- Medicines Company
- NIHR Bristol Biomedical Research Centre
- Cancer Research UK
- National Institute for Health and Care Research (NF-SI-0611-10168, RSES/PDA/C2/017, DRF-2011-04-016, NF-SI-0616-10111, NIHR200268, NF-SI-0507-10259, NF-SI-0617-10145)
- Department of Health and Social Care
- Academy of Medical Sciences (AMS-SGCL13-Blencowe)
- University of Bristol (MC_UU_00,011/3)
- Curtin University of Technology
- Canada Research Chairs (Tier1)
- Biosensors International Group
- National Institutes of Health
- Medical Research Council (MR/K025635/1, MC_UU_12023/21, MC_UU_12023, MR/L004933/1, MR/K025643/1, MC_UU_00011/3, MR/J004855/1, MR/M025209/1, MR/S001751/1, MR/L004933/2, MC_UU_00011)
- National Health and Medical Research Council (1088535)
- National Eye Institute (UG1EY020522)
- Topics
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Meta-analysis and systematic reviews
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Clinical Trials
- Physical Sciences › Mathematics › Statistics and Probability › Advanced Causal Inference Techniques
- Keywords
- RoB 2, risk of bias assessment, randomised trials, Cochrane risk of bias tool, bias in clinical trials, systematic review methodology
- MeSH terms
- Research Design, Bias
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-09-29, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-09-29 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.