How reliable are clinical systems in the UK NHS? A study of seven NHS organisations
Open accessThe DOI matches its Crossref record.
Abstract
Background: It is well known that many healthcare systems have poor reliability; however, the size and pervasiveness of this problem and its impact has not been systematically established in the UK. The authors studied four clinical systems: clinical information in surgical outpatient clinics, prescribing for hospital inpatients, equipment in theatres, and insertion of peripheral intravenous lines. The aim was to describe the nature, extent and variation in reliability of these four systems in a sample of UK hospitals, and to explore the reasons for poor reliability. Methods: Seven UK hospital organisations were involved; each system was studied in three of these. The authors took delivery of the systems' intended outputs to be a proxy for the reliability of the system as a whole. For example, for clinical information, 100% reliability was defined as all patients having an agreed list of clinical information available when needed during their appointment. Systems factors were explored using semi-structured interviews with key informants. Common themes across the systems were identified. Results: Overall reliability was found to be between 81% and 87% for the systems studied, with significant variation between organisations for some systems: clinical information in outpatient clinics ranged from 73% to 96%; prescribing for hospital inpatients 82–88%; equipment availability in theatres 63–88%; and availability of equipment for insertion of peripheral intravenous lines 80–88%. One in five reliability failures were associated with perceived threats to patient safety. Common factors causing poor reliability included lack of feedback, lack of standardisation, and issues such as access to information out of working hours. Conclusions: Reported reliability was low for the four systems studied, with some common factors behind each. However, this hides significant variation between organisations for some processes, suggesting that some organisations have managed to create more reliable systems. Standardisation of processes would be expected to have significant benefit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magrabi, F., Ammenwerth, E., McNair, J. B., De Keizer, N. F., Hyppönen, H., Nykänen, P., Rigby, M., Scott, P. J., Vehko, T., Wong, Z. S.-Y., et al. (2019) · Yearbook of Medical Informatics · doi:10.1055/s-0039-1677903 · Cited by 347
Does quality improvement improve quality?
Dixon-Woods, M., & Martin, G. P. (2016) · Future Hospital Journal · doi:10.7861/futurehosp.3-3-191 · Cited by 324
Vincent, C., & Amalberti, R. (2016) · doi:10.1007/978-3-319-25559-0 · Cited by 278
Self-citationVincent, C., Burnett, S., & Carthey, J. (2014) · BMJ Quality & Safety · doi:10.1136/bmjqs-2013-002757 · Cited by 217
Self-citationOptimizing nursing time in a day care unit: Quality improvement using Lean Six Sigma methodology
Davies, C., Lyons, C., & Whyte, R. (2019) · International Journal for Quality in Health Care · doi:10.1093/intqhc/mzz087 · Cited by 39
Metadata
- Authors
- Burnett, S., Franklin, B. D., Moorthy, K., Cooke, M. W., & Vincent, C.
- Venue
- BMJ Quality & Safety
- Publisher
- BMJ
- Published
- 2012-04-11
- Volume
- 21
- Issue
- 6
- Pages
- 466-472
- ISSN
- 1475-3898 (ISSN-L)
- 2044-5415
- 2044-5423
- OpenAlex
- W2119573062
- Cited by
- 36
- References
- 0
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How reliable are clinical systems in the UK NHS? A study of seven NHS organisations. https://app.cochat.ai/papers/10.1136/bmjqs-2011-000442
- The paper
- Burnett, S., Franklin, B. D., Moorthy, K., Cooke, M. W., & Vincent, C. (2012). How reliable are clinical systems in the UK NHS? A study of seven NHS organisations. BMJ Quality & Safety. https://doi.org/10.1136/bmjqs-2011-000442
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.