CoChat

Ultrasound-guided intravenous catheter survival impacted by amount of catheter residing in the vein

Pandurangadu, Ananda Vishnu, Tucker, Jared, Brackney, Abigail R, Bahl, Amit · 2018 · Emergency Medicine Journal
Cited by 75

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: Ultrasound (US)-guided peripheral IVs have a high failure rate. We explore the relationship between the quantity of catheter residing within the vein and the functionality of the catheter over time. Methods: This was a prospective, observational single-site study. Adult ED patients with US-guided IVs had the catheter visualised under ultrasound post-placement. IV placement time and catheter length residing in the vein was obtained. Exclusions included catheter not visualised, patient discharged from ED unless IV failed, <24 hour hospitalisation unless IV failed or patient self-removed IV. Inpatient follow-up occurred within 24, 48 and 72 hours from the IV placement time. Catheter functionality was noted. If the catheter failed, the time and reason for failure was documented. Results: 113 patients were enrolled; 27 were excluded. Of the 86 study subjects, 29 (33.7%) patients’ IVs failed and 57 (66.3%) remained functional. Median time to IV failure was 15.6 hours. 100% of IVs failed when <30% of the catheter was in the vein; 32.4% of IVs failed when 30%–64% of the catheter was in the vein; no IVs failed when ≥65% of the catheter was in the vein (p<0.0002). The HR was 0.71 (95% CI 0.60 to 0.83), and for every 5% increase of catheter in vein, the hazard of the IV failing decreases by 29% (p<0.0001). Conclusion: The quantity of catheter residing in the vein is a key predictor of long-term functionality of US-guided IVs and is strongly associated with the hazard of failure within 72 hours. Catheter failure is high when <30% of the catheter resided in the vein. Optimum catheter survival occurs when ≥65% of the catheter is placed in the vein.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/emermed-2017-206803

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 75

Metadata

Authors
Pandurangadu, A. V., Tucker, J., Brackney, A. R., & Bahl, A.
Venue
Emergency Medicine Journal
Publisher
BMJ
Published
2018-07-18
Volume
35
Issue
9
Pages
550-555
ISSN
  • 1351-0622 (ISSN-L)
  • 1472-0205
  • 1472-0213
OpenAlex
W2883174409
Cited by
75
References
2
FWCI
9.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound-guided intravenous catheter survival impacted by amount of catheter residing in the vein. https://app.cochat.ai/papers/10.1136/emermed-2017-206803
The paper
Pandurangadu, A. V., Tucker, J., Brackney, A. R., & Bahl, A. (2018). Ultrasound-guided intravenous catheter survival impacted by amount of catheter residing in the vein. Emergency Medicine Journal. https://doi.org/10.1136/emermed-2017-206803

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.