Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 208

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Miniprobe confocal laser microscopy for the detection of invisible neoplasia in patients with Barrett’s oesophagus

Pohl, H, Rösch, T, Vieth, M, Koch, M, Becker, V, Anders, M, Khalifa, A C, Meining, A·2008·Gut

Abstract

Objective: The biggest challenge in endoscopic surveillance of Barrett’s oesophagus is better detection of neoplasia in mucosa of normal macroscopic appearance. We evaluated in vivo miniprobe confocal laser microscopy (CLM) for the detection of invisible Barrett’s neoplasia. Design: Prospective two-centre trial in two phases: phase I to establish criteria of Barrett’s neoplasia and phase II to test these criteria. Patients and intervention: 296 biopsy sites in 38 consecutive patients with Barrett’s oesophagus (mean age 62.1 years, 89.5% men, median length of the Barrett’s oesophagus, 3 cm) were examined with standard high-resolution endoscopy and by miniprobe CLM, with precise matching of CLM recordings to biopsy sites. CLM image criteria for normal versus neoplastic Barrett’s oesophagus were established from 95 biopsies of 15 patients (phase I); these criteria were then prospectively tested on 201 biopsies from the remaining patients without visible focal changes (phase II). All 201 CLM video recordings from phase II cases were randomised and blindly evaluated by two gastroenterologists. Main outcome measure: The primary endpoints were accuracy values in diagnosing HGIN or early carcinoma (EC) on a per-biopsy basis. Secondary endpoints included inter-observer agreement. Results: All initially defined miniprobe CLM criteria (phase I) were significantly more frequently detected in HGIN/EC sites compared with sites with no or low grade neoplasia (phase II). In a per-biopsy analysis, sensitivity and specificity for two independent investigators were 75.0% and 88.8%, and 75.0% and 91.0%, respectively, translating at best into a positive predictive value of 44.4% and a negative predictive value of 98.8%. Inter-observer agreement was good (kappa 0.6). Conclusion: Miniprobe CLM showed a high negative predictive value for the diagnosis of endoscopically invisible neoplasia in Barrett’s oesophagus; sensitivity, however, has still to be improved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.2008.157461

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 208

Metadata

Authors
Pohl, H., Rösch, T., Vieth, M., Koch, M., Becker, V, Anders, M., Khalifa, A. C., & Meining, A.
Venue
Gut
Publisher
BMJ
Published
2008-08-28
Volume
57
Issue
12
Pages
1648-1653
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2114076424
Cited by
208
References
1
FWCI
23.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Miniprobe confocal laser microscopy for the detection of invisible neoplasia in patients with Barrett’s oesophagus. https://app.cochat.ai/papers/10.1136/gut.2008.157461
The paper
Pohl, H., Rösch, T., Vieth, M., Koch, M., Becker, V, Anders, M., Khalifa, A. C., & Meining, A. (2008). Miniprobe confocal laser microscopy for the detection of invisible neoplasia in patients with Barrett’s oesophagus. Gut. https://doi.org/10.1136/gut.2008.157461

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.