CoChat

OC-077 Field effect identification via spectroscopic rectal microvasculature enables accurate proximal neoplasia detection by flexible sigmoidoscopy

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Introduction Flexible sigmoidoscopy (flex sig) remains a cornerstone for colorectal cancer (CRC) screening in the UK although concerns have been raised about about isolated proximal neoplasia which is especially common in women.1 Our group has demonstrated using novel polarisation-gated spectroscopy (4D-ELF) that peri-cryptal microvascular blood supply is elevated in the histologically normal mucosa of patients harboring neoplasia elsewhere in their colon (marker of field effect).2–4 We, therefore, wanted to investigate whether this could serve as an adjunct to flex sig. Methods Subjects undergoing colonoscopy were recruited. Microvascular readings were taken from the endoscopically normal rectum with a fibreoptic probe and analysed by an investigator blinded to colonoscopic findings. Specifically, superficially (within 100 micron of tissue surface) oxygenated hemoglobin (SupOxyHb) was calculated. Proximal lesions were defined at the level of the spenic flexure. The performance of distal adenoma and microvascular blood content was calculated. Advanced adenomas (AAs) were defined as size ≥1.0 cm or presence of high-grade dysplasia. Results Our initial data set consisted of 366 patients (age 58±10, 50% female, 28 with AA). Distal adenoma performed poorly at identifying risk proximal AA (sensitivity 11%). Rectal SupOxyHb was elevated by approximately 50% in patients harboring proximal AA (when compared to neoplasia free patients) with an area under receiver operator characteric curve (AUROC) of 0.83. On a separate data set (n=172), the results were validated with an AUROC of 0.84. With regards to gender, the performance in females was excellent. (AUROC=0.88). SupOxyHb was not confounded by demographic factors or benign colonic disease (including hyperplastic polyps) and was insensitive to non-advanced adenomas. Conclusion We demonstrate, for the first time, that evaluation of rectal microvascular hemoglobin was able to sense proximal advanced adenomas with excellent accuracy, markedly outperforming the sentinel adenoma (a conventional marker of field effect). We replicated these results with an independent data set. Furthermore, SupOxyHb worked well in women, a group in which flex sig performs relatively poorly. Our data suggest that rectal EIBS measurement may provide an accurate and inexpensive means of improving performance of flex sig for CRC screening.

Overview

Integrity signals

Registry

Crossref · 10.1136/gut.2009.208975y

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 1

Metadata

Authors
Roy, H. K., Gomes, A., Goldberg, M. J., Ruderman, S., Bianchi, L. K., Rogers, J., Yen, E., & Backman, V
Affiliations
  • University of Chicago (US)
  • Northwestern University (US)
Venue
Gut
Publisher
BMJ
Published
2010-04
Volume
59
Issue
Suppl 1
Pages
A32.1-A32
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2337757152
Cited by
1
References
4
Citations by year
2012: 1
Type
conference abstract
Language
en
Open access
closed
Locations
Gut (publishedVersion)
Topics
  • Health Sciences › Medicine › Oncology › Colorectal Cancer Screening and Detection
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
field effect, oxyhemoglobin, flexible sigmoidoscopy, advanced adenoma detection, colorectal cancer screening, women, hyperplastic polyps, high-grade dysplasia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.