The DOI matches its Crossref record.
A prospective evaluation of cytology from biliary strictures.
Open accessAbstract
BACKGROUND: Bile duct strictures may be benign or malignant. A definite diagnosis is desirable to advise patients of their prognosis and to identify any amenable to curative surgery. AIMS: To compare different methods of cytology sampling from biliary strictures and evaluate the use of cytology in this context. PATIENTS AND METHODS: In a prospective study 54 patients undergoing endoscopic retrograde cholangiopancreatography (ERCP) had cytology samples obtained as follows: (1) biliary stricture brushings, (2) from the screw thread of a "Soehendra stent retriever" inserted through the stricture, (3) from the proximal end of a blocked biliary stent, and (4) cellular material spun down from a 20 ml specimen of bile. Examination of slides and rinsings was performed by an expert cytologist who graded them for the adequacy of the sample and for evidence of malignancy. RESULTS: Prolonged follow up disclosed malignancy in 52 of the 54 cases, the other two being chronic pancreatitis. Bile samples provided adequate cytology samples in 44%, the Soehendra stent retriever in 70%, retrieved stents in 84%, and cytology brush sampling in 96%. Overall, 28 malignancies were detected by cytology, including 14 of 28 pancreatic carcinomas and 12 of 16 cholangiocarcinomas. Twenty two of the malignancies were detected by brush sampling and the other methods added a total of another six cases. CONCLUSIONS: Cytology sampling is best done by brushing the biliary stricture. Cytology sampling can confirm the diagnosis in 75% of cholangiocarcinomas and 50% of pancreatic carcinomas. The techniques involved are simple to perform and should be routine clinical practice whenever potentially malignant biliary strictures are encountered at ERCP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
de Groen, P. C., Gores, G. J., LaRusso, N. F., Gunderson, L. L., & Nagorney, D. M. (1999) · New England Journal of Medicine · doi:10.1056/nejm199910283411807 · Cited by 955
Evaluation and management of intrahepatic and extrahepatic cholangiocarcinoma
Esnaola, N. F., Meyer, J. E., Karachristos, A., Maranki, J. L., Camp, E. R., & Denlinger, C. S. (2016) · Cancer · doi:10.1002/cncr.29692 · Cited by 296
Endoscopic ultrasound-guided fine needle aspiration biopsy of suspected cholangiocarcinoma
Eloubeidi, M. A., Chen, V. K., Jhala, N. C., Eltoum, I. E., Jhala, D., Chhieng, D. C., Syed, S. A., Vickers, S. M., & Mel Wilcox, C. (2004) · Clinical Gastroenterology and Hepatology · doi:10.1016/s1542-3565(04)00005-9 · Cited by 292
Diagnostic utility of peroral cholangioscopy for various bile-duct lesions
Fukuda, Y., Tsuyuguchi, T., Sakai, Y., Tsuchiya, S., & Saisyo, H. (2005) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2005.04.032 · Cited by 264
Diagnostic benefit of biliary brush cytology in cholangiocarcinoma in primary sclerosing cholangitis
Boberg, K. M., Jebsen, P., Clausen, O. P., Foss, A., Aabakken, L., & Schrumpf, E. (2006) · Journal of Hepatology · doi:10.1016/j.jhep.2006.05.010 · Cited by 159
Metadata
- Authors
- Mansfield, J. C., Griffin, S. M., Wadehra, V, & Matthewson, K.
- Venue
- Gut
- Publisher
- BMJ
- Published
- 1997-05
- Volume
- 40
- Issue
- 5
- Pages
- 671-677
- ISSN
- 0017-5749 (ISSN-L)
- 1468-3288
- OpenAlex
- W2013372598
- Cited by
- 234
- References
- 0
- FWCI
- 4.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A prospective evaluation of cytology from biliary strictures. https://app.cochat.ai/papers/10.1136/gut.40.5.671
- The paper
- Mansfield, J. C., Griffin, S. M., Wadehra, V, & Matthewson, K. (1997). A prospective evaluation of cytology from biliary strictures. Gut. https://doi.org/10.1136/gut.40.5.671
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.