Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 344

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial

Open access
Bang, Ji Young, Navaneethan, Udayakumar, Hasan, Muhammad K, Sutton, Bryce, Hawes, Robert, Varadarajulu, Shyam·2019·Gut

Abstract

Objective: Although lumen-apposing metal stents (LAMS) are increasingly used for drainage of walled-off necrosis (WON), their advantage over plastic stents is unclear. We compared efficacy of LAMS and plastic stents for WON drainage. Design: Patients with WON were randomised to endoscopic ultrasound-guided drainage using LAMS or plastic stents. Primary outcome was comparing total number of procedures to achieve treatment success defined as symptom relief in conjunction with WON resolution on CT at 6 months. Secondary outcomes were treatment success, procedure duration, clinical/stent-related adverse events, readmissions, length of hospital stay (LOS) and costs. Results: 60 patients underwent LAMS (n=31) or plastic stent (n=29) placement. There was no significant difference in total number of procedures performed (median 2 (range 2–7) LAMS vs 3 (range 2–7) plastic, p=0.192), treatment success, clinical adverse events, readmissions, LOS and overall treatment costs between cohorts. Although procedure duration was shorter (15 vs 40 min, p<0.001), stent-related adverse events (32.3% vs 6.9%, p=0.01) and procedure costs (US$12 155 vs US$6609, p<0.001) were higher with LAMS. Significant stent-related adverse events were observed ≥3 weeks postintervention in LAMS cohort. Interim audit resulted in protocol amendment where CT scan was obtained at 3 weeks postintervention followed by LAMS removal if WON had resolved. After protocol amendment, there was no significant difference in adverse events between cohorts. Conclusion: Except for procedure duration, there was no significant difference in treatment outcomes between LAMS and plastic stents. To minimise adverse events with LAMS, patients should undergo follow-up imaging and stent removal at 3 weeks if WON has resolved. Trial registration number: NCT02685865 .

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gutjnl-2017-315335

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 344

Metadata

Authors
Bang, J. Y., Navaneethan, U., Hasan, M. K., Sutton, B., Hawes, R., & Varadarajulu, S.
Venue
Gut
Publisher
BMJ
Published
2018-06-01
Volume
68
Issue
7
Pages
1200-1209
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2807603780
Cited by
344
References
17
FWCI
23.33
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial. https://app.cochat.ai/papers/10.1136/gutjnl-2017-315335
The paper
Bang, J. Y., Navaneethan, U., Hasan, M. K., Sutton, B., Hawes, R., & Varadarajulu, S. (2019). Non-superiority of lumen-apposing metal stents over plastic stents for drainage of walled-off necrosis in a randomised trial. Gut. https://doi.org/10.1136/gutjnl-2017-315335

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.