CoChat

Performance of colorectal cancer screening in the European Union Member States: data from the second European screening report

Senore, Carlo, Basu, Partha, Anttila, Ahti, Ponti, Antonio, Tomatis, Mariano, Vale, Diama Bhadra, Ronco, Gugliemo, Soerjomataram, Isabelle, Primic-Žakelj, Maja, Riggi, Emilia, Dillner, Joakim, Elfström, Miriam Klara, Lönnberg, Stefan, Sankaranarayanan, Rengaswamy, Segnan, Nereo · 2019 · Gut
Cited by 179

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Objective: To present comparative data about the performance of colorectal cancer (CRC) screening programmes in the European Union Member States (EU MSs). Design: Cross-sectional study. We analysed key performance indicators—participation rate, positivity rate (PR), detection rate (DR) and positive predictive value for adenomas and CRC—based on the aggregated quantitative data collected for the second EU screening report. We derived crude and pooled (through a random effects model) estimates to describe and compare trends across different MSs/regions and screening protocols. Results: Participation rate was higher in countries adopting faecal immunochemical test (FIT) (range: 22.8%–71.3%) than in those using guaiac faecal occult blood test (gFOBT) (range 4.5%–66.6%), and it showed a positive correlation (ρ=0.842, p<0.001) with participation in breast cancer screening in the same areas. Screening performance showed a large variability. Compliance with referral for colonoscopy (total colonoscopy (TC)) assessment ranged between 64% and 92%; TC completion rate ranged between 92% and 99%. PR and DR of advanced adenomas and CRC were higher in FIT, as compared with gFOBT programmes, and independent of the protocol among men, older subjects and those performing their first screening. Conclusions: The variability in the results of quality indicators across population-based screening programmes highlights the importance of continuous monitoring, as well as the need to promote quality improvement efforts, as recommended in the EU guidelines. The implementation of monitoring systems, ensuring availability of data for the entire process, together with initiatives aimed to enhance reproducibility of histology and quality of endoscopy, represent a priority in screening programmes management.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gutjnl-2018-317293

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 179

Metadata

Authors
Senore, C., Basu, P., Anttila, A., Ponti, A., Tomatis, M., Vale, D. B., Ronco, G., Soerjomataram, I., Primic-Žakelj, M., Riggi, E., Dillner, J., Elfström, M. K., Lönnberg, S., Sankaranarayanan, R., & Segnan, N.
Venue
Gut
Publisher
BMJ
Published
2018-12-10
Volume
68
Issue
7
Pages
1232-1244
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2903903985
Cited by
179
References
2
FWCI
5.56
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of colorectal cancer screening in the European Union Member States: data from the second European screening report. https://app.cochat.ai/papers/10.1136/gutjnl-2018-317293
The paper
Senore, C., Basu, P., Anttila, A., Ponti, A., Tomatis, M., Vale, D. B., Ronco, G., Soerjomataram, I., Primic-Žakelj, M., Riggi, E., Dillner, J., Elfström, M. K., Lönnberg, S., Sankaranarayanan, R., & Segnan, N. (2019). Performance of colorectal cancer screening in the European Union Member States: data from the second European screening report. Gut. https://doi.org/10.1136/gutjnl-2018-317293

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.