Multicentre, prospective, randomised study comparing the diagnostic yield of colon capsule endoscopy versus CT colonography in a screening population (the TOPAZ study)
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Objective: Colon capsule endoscopy (CCE) has shown promise for colorectal neoplasia detection compared with optical colonoscopy (OC), but has not been compared with other screening tests in average risk screening patients. Design: Patients 50 to 75 years of age (African Americans, 45–75 years) were randomised to CCE or CT colonography (CTC) and subsequent blinded OC. The primary endpoint was diagnostic yield of polyps ≥6 mm with CCE or CTC. Secondary endpoints included accuracy for size and histology, examination completeness, number/proportion of subjects with polyps and adenomas ≥6 mm and ≥10 mm, subject satisfaction and safety. Results: From 320 enrolled subjects, data from 286 (89.4%) were evaluable. The proportion of subjects with any polyp ≥6 mm confirmed by OC was 31.6% for CCE versus 8.6% for CTC (pPr non-inferiority and superiority=0.999). The diagnostic yield of polyps ≥10 mm was 13.5% with CCE versus 6.3% with CTC (pPr non-inferiority=0.9954). The sensitivity and specificity of CCE for polyps ≥6 mm was 79.2% and 96.3% while that of CTC was 26.8% and 98.9%. The sensitivity and specificity of CCE for polyps ≥10 mm was 85.7% and 98.2% compared with 50% and 99.1% for CTC. Both tests were well tolerated/safe. Conclusion: CCE was superior to CTC for detection of polyps ≥6 mm and non-inferior for identification of polyps ≥10 mm. CCE should be considered comparable or superior to CTC as a colorectal neoplasia screening test, although neither test is as effective as OC. Trial registration number: ClinicalTrials.gov no: NCT02754661 .
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adenoma detection rate and risk of colorectal cancer and death
Corley, D. A., Jensen, C. D., Marks, A. R., Zhao, W. K., Lee, J. K., Doubeni, C. A., Zauber, A. G., de Boer, J., Fireman, B. H., Schottinger, J. E., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1309086 · Cited by 2,270
Wolf, A. M. D., Fontham, E. T. H., Church, T. R., Flowers, C. R., Guerra, C. E., LaMonte, S. J., Etzioni, R., McKenna, M. T., Oeffinger, K. C., Shih, Y. T., et al. (2018) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21457 · Cited by 1,944
Lin, J. S., Bowles, E. J. A., Williams, S. B., & Morrison, C. C. (2017) · JAMA · doi:10.1001/jama.2017.0562 · Cited by 1,082
Health at a Glance: Europe 2018: State of Health in the EU Cycle
OECD, & Union, E. (2018) · Health at a Glance: Europe · doi:10.1787/health_glance_eur-2018-en · Cited by 524
Cited by
Current and future colorectal cancer screening strategies
Shaukat, A., & Levin, T. R. (2022) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/s41575-022-00612-y · Cited by 516
Screening for Colorectal Cancer
Gupta, S. (2022) · Hematology/Oncology Clinics of North America · doi:10.1016/j.hoc.2022.02.001 · Cited by 212
Screening and Surveillance of Colorectal Cancer: A Review of the Literature
Maida, M., Dahiya, D. S., Shah, Y. R., Tiwari, A., Gopakumar, H., Vohra, I., Khan, A., Jaber, F., Ramai, D., & Facciorusso, A. (2024) · Cancers · doi:10.3390/cancers16152746 · Cited by 43
“The TOPZ trial compared the outcomes of capsule endoscopy and CTC followed by colonoscopy in 286 patients and found the sensitivity and specificity for polyps ≥ 6 mm to be 79.2% and 96.3% for capsule endoscopy compared to 26.8% and 98.9% for CTC [84].”
Influential
Metadata
- Authors
- Cash, B. D., Fleisher, M. R., Fern, S., Rajan, E., Haithcock, R., Kastenberg, D. M., Pound, D., Papageorgiou, N. P., Fernández-Urién, I., Schmelkin, I. J., & Rex, D. K.
- Venue
- Gut
- Publisher
- BMJ
- Published
- 2020-12-18
- Volume
- 70
- Issue
- 11
- Pages
- 2115-2122
- ISSN
- 0017-5749 (ISSN-L)
- 1468-3288
- OpenAlex
- W3119924552
- Cited by
- 74
- References
- 4
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.