The DOI matches its Crossref record.
Serial assessment of left ventricular diastolic function after Fontan procedure
Open accessAbstract
OBJECTIVE: To assess longitudinal changes in systemic ventricular diastolic function late after the Fontan procedure. DESIGN AND PATIENTS: Prospective study of 13 patients at 2.8 (2.0) years (early) and again at 11.4 (2.0) years (late) after the Fontan procedure by Doppler echocardiography with simultaneous ECG, phonocardiogram, and respirometer. SETTING: Tertiary paediatric cardiac centre. RESULTS: The isovolumic relaxation time (IVRT) was significantly longer, and E wave deceleration time, E and A wave velocities, and E:A velocity ratio were reduced compared to normal both early and late after the procedure. The mean (SD) z score of IVRT decreased significantly from +2.50 (1.00) to +1.24 (0.80) (p = 0.002), and the z score of the E wave deceleration time decreased from −1.69 (1.31) to −2.40 (1.47) (p = 0.03) during follow up. The A wave deceleration time also tended to decrease (early 80 (12) ms v late 73 (11) ms, p = 0.13) with increased follow up. There were no changes of the E and A wave velocities and E:A velocity ratio. The E wave velocity was inversely related to IVRT both early (r = −0.82, p = 0.001) and late (r = −0.59, p = 0.034) after the operation. The prevalence of diastolic flow during isovolumic relaxation decreased from 85% (11/13) to 38% (5/13) (p = 0.04), while that of mid diastolic flow increased from 23% (3/13) to 77% (10/13) (p = 0.02) between the two assessments. CONCLUSIONS: Left ventricular diastolic function remains highly abnormal late after the Fontan procedure. The longitudinal changes demonstrated on follow up are compatible with reduction of left ventricular compliance in addition to persisting abnormalities of relaxation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ghaferi, A. A., & Hutchins, G. M. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.10.005 · Cited by 339
Enalapril in Infants With Single Ventricle: Results of a Multicenter Randomized Trial
Hsu, D. T., Zak, V., Mahony, L., Sleeper, L. A., Atz, A. M., Levine, J. C., Barker, P. C., Ravishankar, C., McCrindle, B. W., Williams, R. V., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.927988 · Cited by 296
Role of Cardiovascular Imaging in the Follow-Up of Patients with Fontan Circulation
Moscatelli, S., Borrelli, N., Sabatino, J., Leo, I., Avesani, M., Montanaro, C., & Di Salvo, G. (2022) · Children · doi:10.3390/children9121875 · Cited by 21
Metadata
- Authors
- Cheung, Y. F., Penny, D. J., & Redington, A. N.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2000-04-01
- Volume
- 83
- Issue
- 4
- Pages
- 420-424
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2122147875
- Cited by
- 165
- References
- 0
- FWCI
- 2.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Serial assessment of left ventricular diastolic function after Fontan procedure. https://app.cochat.ai/papers/10.1136/heart.83.4.420
- The paper
- Cheung, Y. F., Penny, D. J., & Redington, A. N. (2000). Serial assessment of left ventricular diastolic function after Fontan procedure. Heart. https://doi.org/10.1136/heart.83.4.420
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.