CoChat

How different from pacemaker patients are recipients of implantable cardioverter-defibrillators with respect to psychosocial adaptation, affective disorders, and quality of life?

Open access
Duru, F, Büchi, S, Klaghofer, R, Mattmann, H, Sensky, T, Buddeberg, C, Candinas, R · 2001 · Heart
Cited by 128

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess differences in psychosocial adaptation, quality of life, and incidence of affective disorders between patients with pacemakers and those with implantable cardioverter-defibrillators (ICDs). DESIGN: Patients aged 40–70 years who underwent a first pectoral implantation of a pacemaker or an ICD system were studied. All subjects were asked to complete the hospital anxiety and depression scale (HAD), the short form general health survey (SF-36), and a specially designed device related questionnaire. Data analysis was performed for three patient groups: pacemaker (n = 76), ICD patients who received therapeutic shocks (n = 45), and ICD patients who did not receive shocks (n = 31). RESULTS: There were no differences between the three patient groups in HAD scores or in any of the SF-36 subscales or summary ratings. Probable depressive disorder (depression score > 10) was observed in 5.2%, 6.5%, and 6.6%, and probable anxiety disorder (anxiety score > 10) in 13.1%, 9.7%, 13.3% of the pacemaker, non-shocked ICD, and shocked ICD patients, respectively. There were no sex differences. However, patients in the shocked ICD group were more likely than those in the other groups to report limitations in their leisure activities, to perceive their device as a “life extender,” and to admit anxiety about battery depletion and technical problems. Forty per cent of shocked ICD patients would be interested in joining a support group. CONCLUSIONS: Despite having distinctly different medical histories and treatments, patients with pacemakers and ICDs responded similarly to validated tools of health status assessment. ICD patients who had received shocks perceived their device as prolonging their life and had greater anxiety about technical problems. Their endorsement of the potential benefits of a support group warrants further investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heart.85.4.375

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 128

Metadata

Authors
Duru, F., Büchi, S., Klaghofer, R., Mattmann, H., Sensky, T., Buddeberg, C., & Candinas, R.
Venue
Heart
Publisher
BMJ
Published
2001-04-01
Volume
85
Issue
4
Pages
375-379
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W1988237729
Cited by
128
References
1
FWCI
2.95
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: How different from pacemaker patients are recipients of implantable cardioverter-defibrillators with respect to psychosocial adaptation, affective disorders, and quality of life? https://app.cochat.ai/papers/10.1136/heart.85.4.375
The paper
Duru, F., Büchi, S., Klaghofer, R., Mattmann, H., Sensky, T., Buddeberg, C., & Candinas, R. (2001). How different from pacemaker patients are recipients of implantable cardioverter-defibrillators with respect to psychosocial adaptation, affective disorders, and quality of life? Heart. https://doi.org/10.1136/heart.85.4.375

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.