Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 183

The DOI matches its Crossref record.

VALVE DISEASE: Prosthetic valve endocarditis

Open access
Piper, C · 2001 · Heart

Abstract

After 40 years of continuous improvements in the design and materials used for prosthetic heart valves, valve replacement surgery is now performed with low morbidity and mortality. These advantages have been hampered by a few but severe adverse effects; in particular, infections of the prosthetic material continue to be an extremely serious complication occurring with a relatively low but increasing frequency ranging from 0.1–2.3% per patient year.1-3 The prosthesis obviously predisposes to device related infections, especially those caused by novobiocin susceptible, coagulase negative staphylococci, which are able to adhere to a variety of surfaces4 and produce an antibiotic resistant biofilm.5 6 Prosthetic valve endocarditis (PVE) is an endovascular, microbial infection occurring on parts of a valve prosthesis or on reconstructed native heart valves.7 It is recommended to determine whether (a) a mechanical prosthesis, (b) a bioprosthetic xenograft, stented or unstented, (c) an allograft, (d) a homograft, or (e) a repaired native valve with or without implantation of an annular ring is involved.8 Although clinical relevance and therapeutic considerations may be similar, infections of devices or lines placed inside the heart but not connected to the endocardial structures should be classified as “polymer associated infections” rather than PVE. PVE should be classified as either being acquired perioperatively, and thus nosocomial (early PVE), or as community acquired (late PVE).8 Because of significant differences in microbiology of PVE observed within the first year of operation and later on, the time cut off point between early and late PVE should be regarded as one year.9 The risk for early PVE is higher (approximately 5%) in patients with replacement surgery during active infective endocarditis, especially if the causal organism is unknown or the antibiotic treatment is insufficient. The incidence of late PVE is lower for mechanical prostheses than …

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heart.85.5.590

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 183

Metadata

Authors
Piper, C.
Venue
Heart
Publisher
BMJ
Published
2001-05-01
Volume
85
Issue
5
Pages
590-593
ISSN
0007-0769 (ISSN-L)
OpenAlex
W2154313489
Cited by
183
References
0
FWCI
2.14
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: VALVE DISEASE: Prosthetic valve endocarditis. https://app.cochat.ai/papers/10.1136/heart.85.5.590
The paper
Piper, C. (2001). VALVE DISEASE: Prosthetic valve endocarditis. Heart. https://doi.org/10.1136/heart.85.5.590

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.