A novel approach to temporary stenting: degradable cardiovascular stents produced from corrodible metal—results 6–18 months after implantation into New Zealand white rabbits
Open accessAbstract
OBJECTIVE: To determine whether corrodible materials may be safely used as biodegradable cardiovascular implants. DESIGN: Corrodible iron stents (> 99.8% iron) were produced from pure iron and laser cut with a stent design similar to a commercially available permanent stent (PUVA-AS16). A total of 16 NOR-I stents were implanted into the native descending aorta of 16 New Zealand white rabbits (mean luminal diameter at the implantation site 3.4 mm, balloon diameter to vessel diameter ratio 1.13). RESULTS: No thromboembolic complications and no adverse events occurred during the follow up of 6–18 months. All stents were patent at repeat angiography after 6 (n = 9), 12 (n = 5), and 18 months (n = 2) with no significant neointimal proliferation, no pronounced inflammatory response, and no systemic toxicity. CONCLUSIONS: This initial in vivo experience suggests that degradable iron stents can be safely implanted without significant obstruction of the stented vessel caused by inflammation, neointimal proliferation, or thrombotic events.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andrews, N. C. (1999) · New England Journal of Medicine · doi:10.1056/nejm199912233412607 · Cited by 2,130
van der Giessen, W. J., Lincoff, A. M., Schwartz, R. S., van Beusekom, H. M. M., Serruys, P. W., Holmes, D. R., Ellis, S. G., & Topol, E. J. (1996) · Circulation · doi:10.1161/01.cir.94.7.1690 · Cited by 852
Initial and 6-Month Results of Biodegradable Poly- l -Lactic Acid Coronary Stents in Humans
Tamai, H., Igaki, K., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Tsuji, T., Motohara, S., & Uehata, H. (2000) · Circulation · doi:10.1161/01.cir.102.4.399 · Cited by 806
Implantation and intermediate-term follow-up of stents in congenital heart disease.
OʼLaughlin, M. P., Slack, M. C., Grifka, R. G., Perry, S. B., Lock, J. E., & Mullins, C. E. (1993) · Circulation · doi:10.1161/01.cir.88.2.605 · Cited by 331
Lincoff, A. M., Furst, J. G., Ellis, S. G., Tuch, R. J., & Topol, E. J. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(96)00584-0 · Cited by 282
Biodegradable Stents: “Fulfilling the Mission and Stepping Away”
Colombo, A., & Karvouni, E. (2000) · Circulation · doi:10.1161/01.cir.102.4.371 · Cited by 182
van Beusekom, H. M. M., Whelan, D. M., Hofma, S. H., Krabbendam, S. C., van Hinsbergh, V. W. M., Verdouw, P. D., & van der Giessen, W. J. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00348-9 · Cited by 167
Yamawaki, T., Shimokawa, H., Kozai, T., Miyata, K., Higo, T., Tanaka, E., Egashira, K., Shiraishi, T., Tamai, H., Igaki, K., et al. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00312-x · Cited by 156
Clumming, R. L. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002033420523 · Cited by 142
Clinical use of the total dose intravenous infusion of iron dextran.
Auerbach, M., Witt, D., Toler, W. T., Fierstein, M., Lerner, R. G., & Ballard, H. S. (1988) · PubMed · Cited by 97
A Biodegradable Poly‐l‐lactic Acid Coronary Stent in the Porcine Coronary Artery
Tamai, H., Igaki, K., Tsuji, T., Kyo, E., Kosuga, K., Kawashima, A., Matsui, S., Komori, H., Motohara, S., Uehata, H., et al. (1999) · Journal of Interventional Cardiology · doi:10.1111/j.1540-8183.1999.tb00673.x · Cited by 76
Initial and 6-Month Results of Biodegradable Poly-l-Lactic Acid Coronary Stents in Humans
HideoTamai, KeijiIgaki, EishoKyo, KunihikoKosuga, AkiyoshiKawashima, ShigeoMatsui, HidenoriKomori, TakafumiTsuji, SeiichiroMotohara, & HiromuUehata (2000) · Circulation · Cited by 56
Cited by
Zheng, Y. F., Gu, X. N., & Witte, F. (2014) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2014.01.001 · Cited by 2,436
Development of new metallic alloys for biomedical applications
Niinomi, M., Nakai, M., & Hieda, J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.06.037 · Cited by 1,623
In vitro corrosion and biocompatibility of binary magnesium alloys
Gu, X., Zheng, Y., Cheng, Y., Zhong, S., & Xi, T. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2008.10.021 · Cited by 1,343
Recent advances on the development of magnesium alloys for biodegradable implants
Chen, Y., Xu, Z., Smith, C., & Sankar, J. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.07.005 · Cited by 1,236
Coronary stents: A materials perspective
Mani, G., Feldman, M. D., Patel, D., & Agrawal, C. M. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.042 · Cited by 866
Metadata
- Authors
- Peuster, M., Wohlsein, P., Brügmann, M., Ehlerding, M., Seidler, K., Fink, C., Brauer, H., Fischer, A., & Hausdorf, G.
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2001-11-01
- Volume
- 86
- Issue
- 5
- Pages
- 563-569
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W1983433001
- Cited by
- 569
- References
- 12
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.