CoChat

Comprehensive cardiac rehabilitation programme for implantable cardioverter-defibrillator patients: a randomised controlled trial

Open access
Fitchet, A, Doherty, P J, Bundy, C, Bell, W, Fitzpatrick, A P, Garratt, C J · 2003 · Heart
Cited by 147

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Objective: To investigate the effects of a 12 week comprehensive cardiac rehabilitation (CCR) programme on patients who have undergone implantation of an implantable cardioverter-defibrillator (ICD). Design: Sixteen patients with ICDs (14 (88%) male, mean (SD) age 58 (10) years, range 34–74 years) were randomised to either attend an individually tailored CCR programme or receive usual care. They then changed to the alternative regimen for a further 12 weeks. Exercise capacity was assessed using a treadmill exercise test at baseline, after usual care, after CCR and 12 weeks after CCR to assess maintenance effects. Hospital anxiety and depression (HAD) scores were recorded at each stage. Results: Exercise times (min:s; mean (SD)) increased by 16% from a baseline mean of 9:55 (2:33) to 11:11 (2:17) following attendance at CCR (95% confidence interval (CI) 0:34 to 1:58; p = 0.001). This improvement was maintained 12 weeks after attendance at CCR, at 11:20 (2:17) (p = 1.00). HAD scores for anxiety and depression decreased during CCR from a baseline of 13.4 (3.6) to 8.1 (3.6), 95% CI 3.5 to 7.0 (p < 0.001) and 9.9 (3.4) to 6.7 (2.9), 95% CI 1.9 to 4.4 (p = 0.002), respectively. These improvements were maintained at 12 weeks after CCR. No ventricular arrhythmias or ICD discharges occurred during the exercise components of the CCR. The total number of ventricular arrhythmias and ICD discharges was similar 12 weeks before, during, and 12 weeks after CCR. Conclusions: CCR appears to be safe for patients with ICDs. It can improve exercising ability and lower the levels of psychological distress. A larger multicentre study is recommended to confirm these findings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heart.89.2.155

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 147

Metadata

Authors
Fitchet, A., Doherty, P. J., Bundy, C., Bell, W., Fitzpatrick, A. P., & Garratt, C. J.
Venue
Heart
Publisher
BMJ
Published
2003-02
Volume
89
Issue
2
Pages
155-160
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2100316199
Cited by
147
References
3
FWCI
3.35
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comprehensive cardiac rehabilitation programme for implantable cardioverter-defibrillator patients: a randomised controlled trial. https://app.cochat.ai/papers/10.1136/heart.89.2.155
The paper
Fitchet, A., Doherty, P. J., Bundy, C., Bell, W., Fitzpatrick, A. P., & Garratt, C. J. (2003). Comprehensive cardiac rehabilitation programme for implantable cardioverter-defibrillator patients: a randomised controlled trial. Heart. https://doi.org/10.1136/heart.89.2.155

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.