CoChat

Risk factors for pacemaker implantation following aortic valve replacement: a single centre experience

Open access
Limongelli, G, Ducceschi, V, D’Andrea, A, Renzulli, A, Sarubbi, B, De Feo, M, Cerasuolo, F, Calabrò, R, Cotrufo, M · 2003 · Heart
Cited by 153

The DOI matches its Crossref record.

Abstract

Objective: To identify perioperative clinical predictors of permanent pacemaker implantation following aortic valve replacement. Design and patients: Prospective cohort study on 276 patients submitted for aortic valve replacement: 267 patients (mean (SD) age, 57.5 (14) years) with no conduction disturbances, and nine patients (67.7 (5) years) with severe conduction disturbances requiring permanent pacing; 65 perioperative variables (38 preoperative, eight intraoperative, and 19 postoperative) were considered. Results: Nine patients (3.2%) had irreversible second or third degree atrioventricular (AV) block requiring permanent pacing. Risk factors for permanent pacing identified by univariate analysis were: preoperative: additional valvar disease, aortic regurgitation, myocardial infarction, pulmonary hypertension, anaemia, use of digitalis; intraoperative: cardiac arrest; postoperative: cardiac arrest, conduction disturbances, electrolytic imbalance, angiotensin converting enzyme inhibitor use. Multivariate logistic regression analysis identified preoperative aortic regurgitation (p < 0.005; odds ratio (OR) 6.6, 95% confidence interval (CI) 1.6 to 12.2), myocardial infarction (p < 0.0005; OR 15.2, 95% CI 6.3 to 19.9), pulmonary hypertension (p < 0.005; OR 12.5, 95% CI 3.2 to 18.3), and postoperative electrolyte imbalance (p < 0.01; OR 4.5, 95% CI 1.3 to 6.4). Conclusions: Irreversible AV block requiring permanent pacemaker implantation is an uncommon condition following aortic valve replacement. Previous aortic regurgitation, myocardial infarction, pulmonary hypertension, and postoperative electrolyte imbalance should be considered in order to identify patients at increased risk for advanced AV block.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heart.89.8.901

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 153

Metadata

Authors
Limongelli, G., Ducceschi, V, D’Andrea, A., Renzulli, A., Sarubbi, B., De Feo, M., Cerasuolo, F., Calabrò, R., & Cotrufo, M.
Venue
Heart
Publisher
BMJ
Published
2003-07-14
Volume
89
Issue
8
Pages
901-904
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2118088704
Cited by
153
References
0
FWCI
1.68
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Risk factors for pacemaker implantation following aortic valve replacement: a single centre experience. https://app.cochat.ai/papers/10.1136/heart.89.8.901
The paper
Limongelli, G., Ducceschi, V, D’Andrea, A., Renzulli, A., Sarubbi, B., De Feo, M., Cerasuolo, F., Calabrò, R., & Cotrufo, M. (2003). Risk factors for pacemaker implantation following aortic valve replacement: a single centre experience. Heart. https://doi.org/10.1136/heart.89.8.901

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.