CoChat

Velocity ratio predicts outcomes in patients with low gradient severe aortic stenosis and preserved EF

Jander, Nikolaus, Hochholzer, Willibald, Kaufmann, Beat A, Bahlmann, Edda, Gerdts, Eva, Boman, Kurt, Chambers, John B, Nienaber, Christoph A, Ray, Simon, Rossebo, Anne, Pedersen, Terje R, Wachtell, Kristian, Gohlke-Bärwolf, Christa, Neumann, Franz-Josef, Minners, Jan · 2014 · Heart
Cited by 52

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Objective: To evaluate the usefulness of velocity ratio (VR) in patients with low gradient severe aortic stenosis (LGSAS) and preserved EF. Background: LGSAS despite preserved EF represents a clinically challenging entity. Reliance on mean pressure gradient (MPG) may underestimate stenosis severity as has been reported in the context of paradoxical low flow, LGSAS. On the other hand, grading of stenosis severity by aortic valve area (AVA) may overrate stenosis severity due to erroneous underestimation of LV outflow tract (LVOT) diameter, small body size or inconsistencies in cut-off values for severe stenosis. We hypothesised that VR may have conceptual advantages over MPG and AVA, predict clinical outcomes and thereby be useful in the management of patients with LGSAS. Methods: Patients from the prospective Simvastatin and Ezetimibe in Aortic Stenosis (SEAS) study with an AVA<1.0 cm 2, MPG≤40 mm Hg and EF≥55% and asymptomatic at baseline were stratified according to VR with a cut-off value of 0.25. Outcomes were evaluated according to aortic valve-related events and cardiovascular death. Results: Of 435 patients with LGSAS, 197 (45%) had VR<0.25 suggesting severe and 238 (55%) had VR≥0.25 suggesting non-severe stenosis. Aortic valve-related events (mean follow-up 42±14 months) were more frequent in patients with VR<0.25 (57% vs 41%; p<0.001) as was cardiovascular death within the first 24 months (p<0.05). In multivariable Cox regression analysis, MPG was the strongest independent predictor of aortic valve events (p<0.001) followed by VR (p<0.02). Adjusting AVA by VR increased predictive accuracy for aortic valve events (area under the receiver operating curve 0.62 (95% CI 0.57 to 0.67) vs 0.56 (95% CI 0.51 to 0.61) for AVA, p=0.02) with net reclassification improvement calculated at 0.36 (95% CI 0.17 to 0.54, p<0.001). VR did not improve the prediction of clinical events by MPG. Conclusions: In the difficult setting of LGSAS, VR shows a strong association with valve-related events and—although not outperforming MPG—may be particularly useful in guiding clinical management. Trial registration number: NCT00092677.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/heartjnl-2014-305763

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 52

Metadata

Authors
Jander, N., Hochholzer, W., Kaufmann, B. A., Bahlmann, E., Gerdts, E., Boman, K., Chambers, J. B., Nienaber, C. A., Ray, S., Rossebo, A., Pedersen, T. R., Wachtell, K., Gohlke-Bärwolf, C., Neumann, F.-J., & Minners, J.
Venue
Heart
Publisher
BMJ
Published
2014-09-12
Volume
100
Issue
24
Pages
1946-1953
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W2148236081
Cited by
52
References
5
FWCI
4.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Velocity ratio predicts outcomes in patients with low gradient severe aortic stenosis and preserved EF. https://app.cochat.ai/papers/10.1136/heartjnl-2014-305763
The paper
Jander, N., Hochholzer, W., Kaufmann, B. A., Bahlmann, E., Gerdts, E., Boman, K., Chambers, J. B., Nienaber, C. A., Ray, S., Rossebo, A., Pedersen, T. R., Wachtell, K., Gohlke-Bärwolf, C., Neumann, F.-J., & Minners, J. (2014). Velocity ratio predicts outcomes in patients with low gradient severe aortic stenosis and preserved EF. Heart. https://doi.org/10.1136/heartjnl-2014-305763

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.