CoChat

Determinants of implantable defibrillator discharges in high-risk patients with hypertrophic cardiomyopathy: Figure 1

Open access
Woo, Anna, Monakier, Daniel, Harris, Louise, Hill, Ann, Shah, Prasad, Wigle, E Douglas, Rakowski, Harry, Rozenblyum, Evelyn, Cameron, Douglas A · 2007 · Heart
Cited by 79

The DOI matches its Crossref record.

Abstract

Objectives: To identify the determinants of appropriate and inappropriate implantable cardioverter-defibrillator (ICD) discharges in patients with hypertrophic cardiomyopathy (HCM). Design: Retrospective cohort study. Setting: ICD clinic at an academic hospital. Patients: 61 patients with HCM who received ICDs for the primary or secondary prevention of sudden cardiac death (SCD). Outcome measures: (a) Analysis of appropriate and inappropriate ICD discharges; (b) predictors of ICD discharges. Results: Mean (SD) age at ICD insertion was 46 (18) years (range 10–79). Follow-up time was 40 (27) months (range 7–151). Eight patients experienced an appropriate discharge, occurring 24.5 (13.6) months after ICD insertion. Appropriate ICD intervention was more common in the secondary (36%) than the primary (8%) prevention group (p = 0.02). Inappropriate ICD discharges occurred in 20 (33%) patients. Multivariate Cox regression analysis identified two significant predictors of inappropriate ICD discharges: (a) age <30 years at the time of ICD insertion (hazard ratio (HR) = 3.0 (95% CI 1.1 to 8.0; p = 0.03) and (b) history of atrial fibrillation (HR = 3.1 (95% CI 1.2 to 8.1; p = 0.02). Conclusions: ICDs are effective in the prevention of SCD in HCM. However, there is a high incidence of inappropriate ICD discharges.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/hrt.2006.090290

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 79

Metadata

Authors
Woo, A., Monakier, D., Harris, L., Hill, A., Shah, P., Wigle, E. D., Rakowski, H., Rozenblyum, E., & Cameron, D. A.
Venue
Heart
Publisher
BMJ
Published
2007-08-14
Volume
93
Issue
9
Pages
1044-1045
ISSN
  • 1355-6037 (ISSN-L)
  • 1468-201X
OpenAlex
W1997100480
Cited by
79
References
0
FWCI
5.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Determinants of implantable defibrillator discharges in high-risk patients with hypertrophic cardiomyopathy: Figure 1. https://app.cochat.ai/papers/10.1136/hrt.2006.090290
The paper
Woo, A., Monakier, D., Harris, L., Hill, A., Shah, P., Wigle, E. D., Rakowski, H., Rozenblyum, E., & Cameron, D. A. (2007). Determinants of implantable defibrillator discharges in high-risk patients with hypertrophic cardiomyopathy: Figure 1. Heart. https://doi.org/10.1136/hrt.2006.090290

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.